These benchtop autoclave is designed to generate and control the high temperatures required to kill microorganisms on surfaces or in solutions of laboratory supplies. Scitek benchtop sterilizers are meet the most stringent CE standards.

  • Vertical Pressure Steam Sterilizer ST-V200L
    Model : ST-V200L

    Capacity : 200L
    Control : Automatic Control
    The Main Material : 304 Stainless steel
    Sterilization Chamber Volume (DxH)(mm) : 500x1000
    Large capacity vertical pressure steam autoclave with small footprint.
  • Automatic Vertical Autoclave 50/80/100/120/150L
    Model : ST-V50A; ST-V80A; ST-V100A; ST-V120A; ST-V150A

    Sterilization Temperature (℃) : 105~136
    Max. Sterilization Pressure (Mpa) : 0.23
    Drying Function : YES
    Water Injection Method : Built-in water tank
    Drying Time : 15min
    The automatic vertical autoclave with LCD touch screen and water tank has the advantage of a continuous water supply and improved sterilisation results, making it an efficient sterilisation option for laboratories.
  • Benchtop Pulse Vacuum Autoclave, Class B
    Model : ST-B60PV; ST-B80PV

    Capacity : 60L; 80L
    Chamber Size(mm) : φ386x520; φ386x692
    Designed Pressure : -0.1/0.3Mpa
    Large capacity pulse vacuum autoclave with small footprint.
  • Vertical Flip-top Steam Sterilizer
    Model: ST-V60F; ST-V85F; ST-V100F
     
    Capacity(L): 60; 85; 100
    Sterilization Temperature Setting Range: 105–138 ℃
    Maximum Operating Pressure: 0.27 MPa
    Chamber Size (Dia×H)(mm): Ø405×506; Ø405×706; Ø405×831
    Multiple Protection Function: Yes
    Vertical flip-top steam sterilizer with a flip-top structure can save more space. Moreover, this product is equipped with a 7-inch true-color touchscreen, which can display multiple important parameters simultaneously.
  • Vertical Pulse Vacuum Steam Autoclave
    Model : ST-V35PVM; ST-V50PVM; ST-V75PVM; ST-V100PVM

    Volume : 35L/50L/75L/100L
    Design Pressure : 0.25Mpa
    Design Temperature : 139℃
    Sterilization Temperature : 116℃~134℃
    Sterilization Time Setting Range : 4~120 min
    Drying Time Setting Range : 0~240min
    The vertical pulse vacuum steam autoclave features more efficient vacuum degassing, steam sterilisation, etc., and is suitable for use in sterilisation applications where higher requirements for sterilisation results are required.
  • Vertical Pulse Vacuum Autoclave 50/80/100/120/150L
    Model : ST-V50PV; ST-V80PV; ST-V100PV; ST-V120PV; ST-V150PV

    Sterilization Temperature (℃) : 105~136
    Max. Sterilization Pressure (Mpa) : 0.23
    Drying Function : YES
    Water Injection Method : Built-in water tank
    Drying Time : 15min
    The vertical pulse vacuum autoclave offers high capacity and easy-to-use controls in a compact unit.
  • Horizontal Pulse Vacuum Autoclave 60-450L
    Model : ST-H60PV; ST-H80PV; ST-H100PV; ST-H150PV; ST-H200PV; ST-H300PV; ST-H450PV

    Capacity (L) : 60 / 80 / 100  / 150  / 200 / 300 / 450
    Chamber Size(mm) : Ø386x500 / Ø386x700 / Ø386x950 / Ø500x780 / Ø500x1000 / Ø650x950 / Ø650x1360
    Sterilization Temperature (℃) : 105~136
    Max. Sterilization Pressure (Mpa) : 0.23
    Drying Function : YES
    The horizontal pulse vacuum autoclave provides more efficient vacuum degassing with precise control of temperature, pressure and time to ensure safe and effective sterilisation.
  • Horizontal Pulse Vacuum Autoclave, Motor Hinge Door
    Model : ST-BA650PV; ST-BA800PV; ST-BA1000PV; ST-BA1200PV; ST-BA1500PV

    Volume(L) : 650 / 800 / 1000 / 1200 / 1500
    Chamber Design Pressure : 0.3MPa
    Generator Design Pressure : 1.0MPa
    Design Temperaure : 150℃
    Maximum Operating Temperature : 139℃
    This Autoclave needs to be used with an air compressor
  • Horizontal Pulse Vacuum Autoclave with Lift Door
    Model : ST-BV150PV; ST-BV180PV; ST-BV250PV; ST-BV300PV; ST-BV360PV; ST-BV450PV; ST-BV600PV; ST-BV800PV
    Volume(L) : 150 / 180 / 250 / 300 / 360 / 450 / 600 / 800
    Chamber Design Pressure : -0.1/0.3MPa
    Generator Design Pressure : 1MPa
    Design Temperaure : 150℃
    Maximum Operating Temperature : 139℃
    This Autoclave needs to be used with an air compressor
    This horizontal pulse vacuum autoclave autoclaves all items in the laboratory, including liquids.
  • Horizontal Pulse Vacuum Autoclave, Sliding Door
    Model : ST-BH1200PV; ST-BH1500PV

    Chamber Design Pressure : -0.1/0.3MPa
    Jecket Design Pressure : 0.3MPa
    Generator Design Pressure : 1.0MPa
    Design Temperaure : 150℃
    Maximum Operating Temperature : 139℃
    The horizontal pulse vacuum autoclave features more efficient vacuum degassing, steam sterilisation, fast response, encapsulation, steam sealing.
Contact us

About Company​​​​​​​

As a professional lab and medical equipment manufacturer, Scitek Global is certified by ISO 9001, ISO 13485, ISO 45001 and ISO 14001. Almost all our products are certified by ETL, CE and FDA .

Scitek Global looks forward to establishing cooperation with more distributors all over the world, and working together to create greater customer value.

Quick Links

Contact Us
Scitek Global Co.,Ltd
  No. 7000 Jingshi Road, Jinan City, Shandong Province, China
/  +86-531-82893797
  Inquiry: info@scitekglobal.com
 

9999 Bellaire Blvd Ste 505, Houston, TX 77036, United States
  +1 (915) 4126735
info@scitekglobal.net
 
Copyright © 2023 Scitek Global Co., Ltd. All rights reserved.  Sitemap  Privacy Policy