Model | ST-V50PV | ST-V80PV | ST-V100PV | ST-V120PV | ST-V150PV |
Capacity | 50L | 80L | 100L | 120L | 150L |
External Size (WxDxH)(mm) | 580x636x990 | 636x710x1030 | 630x710x1295 | 700x780x1190 | 780x850x1180 |
Chamber Size (ØxH)(mm) | Ø316x667 | Ø386x695 | Ø386x860 | Ø450x760 | Ø500x780 |
Chamber Material | SUS304 | ||||
Sterilization Temperature | 105~136 ℃ | ||||
Designed Temperature | 150℃ | ||||
Max. Working Temperature | 136 ℃ | ||||
Dissolution Temperature | 40~100℃ | ||||
Warming Temperature | 40~60℃ | ||||
Temp.Accuracy | 0.1℃ | ||||
Temp. Uniformity | ≤±0.5℃ | ||||
Designed Pressure | 0.3Mpa | ||||
Max.Sterilization Pressure | 0.23Mpa | ||||
Ultimate Vacuum | -0.096MPa | ||||
Pressure Resoluiton | 0.1KPa | ||||
Sterilization Time Range | 0~99min | ||||
Temp. Controller | PID control by microprocessor | ||||
Display | LCD touch screen | ||||
Drying Function | YES | ||||
Drying Time | 15min | ||||
Sterilization Program | ●Medical instrument program ●Luminal instruments ●Dressings/Fabric program ●Rubber program ●Liquid program ●BD Test program ●Vacuum Test progrm Sterilization of medical dressing, medical Instruments, Instruments with cavity, Rubber, liquids plus 4 user-customized programs BD Test and vacuum test. | ||||
Water Injection Method | Built-in water tank | ||||
Power Consumption | 3KW | 4.5KW | 5.4KW | 7.2KW | 9.3KW |
Power Supply | 220V 50Hz | 220V 50Hz | 220V 50Hz | 380V 50Hz | 380V 50Hz |
Standard SS Basket | 2pcs | 2pcs | 2pcs | 2pcs | 2pcs |
Optional Accessories | Printer,USB port | ||||
Net Weight | 85kg | 95kg | 112kg | 180kg | 210kg |
Gross Weight | 120kg | 130kg | 152kg | 220kg | 250kg |
Shipping Size (WxDxH)(mm) | 830x840x1250 | 880x910x1300 | 880x910x1550 | 1030x1050x1300 | 1030x1050x1450 |
Overheat protection: Automatically cutting off heating with audible and visual indication when the autoclave is overheated.
Anti-burning protection: Automatically cutting off heating with audible and visual indication when the autoclave is lack of water.
Interlock safety: Preventing from starting a cycle if door is not properly closed or from door opening if there is pressure inside chamber.
Steam pressure safety valve: Automatically works when the chamber pressure exceeds the limit.
Automatic operation from sterilization to drying (Pre-vacuum sequence, heating, sterilization, steam discharge and post-vacuum drying) can be easily set and monitored by the LCD touch screen
Built-in vacuum pump provides 3-time pulsed vacuum process,extracting the air out of the medical dressing and the Class A hollow medical instrument efficiently.
Built-in steam generator prevents the media from contamination.
Post-vacuum drying function offers efficient drying results.
Positive pulsing function removes the air efficiently.
With 0.22µm air filter, blocks all microorganisms from exiting the chamber during the air removal phase.
Optional printer, real-time record sterilization process, error and alarm information.
The vertical pulse vacuum autoclave is of vertical design, space-saving, suitable for small laboratories or medical institutions.
Inlet or drain connection design
The top of the vacuum sterilizer is equipped with a vacuum pressure gauge to facilitate real-time monitoring of the working pressure. The control knob and emergency stop button are clearly visible and user-friendly.
The vacuum sterilizer is wrapped in a transparent film, placed on a wooden base and packed in a wooden transport case for long distance transportation.
Model | ST-V50PV | ST-V80PV | ST-V100PV | ST-V120PV | ST-V150PV |
Capacity | 50L | 80L | 100L | 120L | 150L |
External Size (WxDxH)(mm) | 580x636x990 | 636x710x1030 | 630x710x1295 | 700x780x1190 | 780x850x1180 |
Chamber Size (ØxH)(mm) | Ø316x667 | Ø386x695 | Ø386x860 | Ø450x760 | Ø500x780 |
Chamber Material | SUS304 | ||||
Sterilization Temperature | 105~136 ℃ | ||||
Designed Temperature | 150℃ | ||||
Max. Working Temperature | 136 ℃ | ||||
Dissolution Temperature | 40~100℃ | ||||
Warming Temperature | 40~60℃ | ||||
Temp.Accuracy | 0.1℃ | ||||
Temp. Uniformity | ≤±0.5℃ | ||||
Designed Pressure | 0.3Mpa | ||||
Max.Sterilization Pressure | 0.23Mpa | ||||
Ultimate Vacuum | -0.096MPa | ||||
Pressure Resoluiton | 0.1KPa | ||||
Sterilization Time Range | 0~99min | ||||
Temp. Controller | PID control by microprocessor | ||||
Display | LCD touch screen | ||||
Drying Function | YES | ||||
Drying Time | 15min | ||||
Sterilization Program | ●Medical instrument program ●Luminal instruments ●Dressings/Fabric program ●Rubber program ●Liquid program ●BD Test program ●Vacuum Test progrm Sterilization of medical dressing, medical Instruments, Instruments with cavity, Rubber, liquids plus 4 user-customized programs BD Test and vacuum test. | ||||
Water Injection Method | Built-in water tank | ||||
Power Consumption | 3KW | 4.5KW | 5.4KW | 7.2KW | 9.3KW |
Power Supply | 220V 50Hz | 220V 50Hz | 220V 50Hz | 380V 50Hz | 380V 50Hz |
Standard SS Basket | 2pcs | 2pcs | 2pcs | 2pcs | 2pcs |
Optional Accessories | Printer,USB port | ||||
Net Weight | 85kg | 95kg | 112kg | 180kg | 210kg |
Gross Weight | 120kg | 130kg | 152kg | 220kg | 250kg |
Shipping Size (WxDxH)(mm) | 830x840x1250 | 880x910x1300 | 880x910x1550 | 1030x1050x1300 | 1030x1050x1450 |
Overheat protection: Automatically cutting off heating with audible and visual indication when the autoclave is overheated.
Anti-burning protection: Automatically cutting off heating with audible and visual indication when the autoclave is lack of water.
Interlock safety: Preventing from starting a cycle if door is not properly closed or from door opening if there is pressure inside chamber.
Steam pressure safety valve: Automatically works when the chamber pressure exceeds the limit.
Automatic operation from sterilization to drying (Pre-vacuum sequence, heating, sterilization, steam discharge and post-vacuum drying) can be easily set and monitored by the LCD touch screen
Built-in vacuum pump provides 3-time pulsed vacuum process,extracting the air out of the medical dressing and the Class A hollow medical instrument efficiently.
Built-in steam generator prevents the media from contamination.
Post-vacuum drying function offers efficient drying results.
Positive pulsing function removes the air efficiently.
With 0.22µm air filter, blocks all microorganisms from exiting the chamber during the air removal phase.
Optional printer, real-time record sterilization process, error and alarm information.
The vertical pulse vacuum autoclave is of vertical design, space-saving, suitable for small laboratories or medical institutions.
Inlet or drain connection design
The top of the vacuum sterilizer is equipped with a vacuum pressure gauge to facilitate real-time monitoring of the working pressure. The control knob and emergency stop button are clearly visible and user-friendly.
The vacuum sterilizer is wrapped in a transparent film, placed on a wooden base and packed in a wooden transport case for long distance transportation.