You are here: Home » Products

Product Category

  • Tap Density Tester
    Model : DME-100AT; DME-100BT; DME-100CT; DME-100DT

    Channel : 1 / 2 / 3 / 1
    Weight of Testing Object : ≤500.00 g
    Volume of Testing Object : ≤250.00 mL / ≤250.00 mL
    Single Vibration Times : ≤0-99999 times / 0-14750 times
    Tap density tester for powders and granular materials.
  • Freezing Point Osmometer, OSM-BF3
    Model: OSM-BF3
     
    Measurement Range: 0-3000 mOsmol/kg H₂O
    Sample Volume: 50 μL-100 μL
    Pre-cooling Time: ≤ 3 minutes
    Test Time: < 90 s
    It is suitable for the osmolality analysis and testing of intravenous injections, intrathecal injections (among other injections), eye drops, blood, urine, etc.
  • Saybolt Viscosity Tester
    Model : SV-0623

    Instrument Structure : Desk type
    Receiving Flask : (60±0.05) mL
    Timing Range : 0.0∼999.9 s
    Working Mode : Double lines, parallel test
    SV-0623 is suitable to determine the Saybolt viscosity of bitumen and bituminous mixtures under a constant temperature as per T0623.
  • Intelligent Rheometer RV-P Series
    Model : RV-P1L; RV-P1R; RV-P1HA; RV-P1HB; RV-P2L; RV-P2R; RV-P2HA; RV-P2HB; RV-P3L; RV-P3R; RV-P3HA; RV-P3HB
     
    Rotate Speed(rpm) : 0.3-100; 0.1-200; 0.1-250;
    Accuracy : ±1.0%(of full range)
    Repeatability : ±0.2%
    Rheometer is an advanced rheometer instrument for controlled rate and controlled stress measurements.
  • Rheometer RV-T2 Series
    Model : RV-T2L; RV-T2R; RV-T2HA; RV-T2HB;
     
    Rotate Speed(rpm) : 0.1-200 rpm(stepless variable speed)
    Accuracy : ±1.0 (F/S)
    Repeatability : 0.5% (F/S)
    Rheometer is an advanced rheometer instrument for controlled rate and controlled stress measurements.
  • Automatic Petroleum Low Temperature Tester
    Model: MPT-L1113
     
    Temp. Control Range: RT. to -53 ℃
    Temp. Control Accuracy: ±1 ℃
    Cooling Time: RT. to -53 ℃, ≤ 120 min
    Bath Capaity: 2.3 L
  • Fully Automatic Pour Point Tester
    Model: ACP-A1117
     
    Temperature Control Range: RT. to -70 ℃
    Temperature Control Accuracy: ±0.1℃
    Detection Method: Photoelectric sensor
    Refrigeration System: Imported cascade compressor
    Test Station: 2 independent testing station
  • Automatic Kinematic Viscosity Tester
    Model: VSC-S1102
     
    Capillary Tube Capacity: 4
    Temp. Measurement Range: RT. to 150 ℃
    Temp. Measurement Accuracy: ±0.01 ℃
    Temp. Control Range: 20–150 ℃
    Temp. Control Accuracy: ±0.05 °C
  • Corrosion of Cast Aluminum Alloys in Engine Coolants Tester
    Model: CAHT-1183
     
    Temperature Range: Ambient to 160 °C
    Temperature Accuracy: ± 0.1 °C
    Timer: Digital Display Timer
    Pressure Monitoring: High-precision analog pressure gauge
    Continuous Operation: Test duration up to 1,000 h
  • Carbon Residue Tester
    Model: CRT-1114
     
    Test Method: Electric Furnace Method
    Temperature Control: 520 °C
    Temperature Accuracy: ≤ ±5 °C
Contact us

About Company​​​​​​​

As a professional lab and medical equipment manufacturer, Scitek Global is certified by ISO 9001, ISO 13485, ISO 45001 and ISO 14001. Almost all our products are certified by ETL, CE and FDA .

Scitek Global looks forward to establishing cooperation with more distributors all over the world, and working together to create greater customer value.

Quick Links

Contact Us
Scitek Global Co., Ltd.
  No. 7000 Jingshi Road, Jinan City, Shandong Province, China
/  +86-531-82893797
  Inquiry: info@scitekglobal.com
 
Scitek Global Inc.
9999 Bellaire Blvd Ste 505, Houston, TX 77036, United States
  +1 (915) 4126735
info@scitekglobal.net
 
Copyright © 2023 Scitek Global Co., Ltd. All rights reserved.  Sitemap  Privacy Policy