You are here: Home » Products » Environment Monitor

Product Category

  • Benchtop COD Analyzer
    Model : COD-1001
     
    Measurement Method : Fast digestion spectrophotometry
    Measuring Range : 10-10000mg/L
    Accuracy : ≤5%
    Resolution : 0.01
    Light Source : Imported Silicon Photodiode
    Sizes(W×D×H)(mm) : 450x370x190
  • Automobile Exhaust Analyzer AEA-201
    Model : AEA-201

    Measuring Range : HC: 0~10000×10-6(ppm)vol; CO: 0~10×10-2(%)vol
    Stability : Moment drift ≤ ±3%; Repeatability ≤ ±2%
    Response Time : 95% response is not more than 10 seconds
    Size (WxDxH)(mm) : 420×310×170
  • Automobile Exhaust Analyzer AEA-301
    Model : AEA-301
    Measuring Range : 
    HC: 0~10000×10-6(ppm)vol
    CO: 0~10×10-2(%)vol
    NOx : 0~4000×10-6(ppm)vol
    Stability : Moment drift ≤ ±3%
    Repeatability ≤ ±2%
    Response Time : 95% response is not more than 10 seconds
    Size (WxDxH)(mm) : 420×310×170
  • Automobile Exhaust Analyzer AEA-401
    Model : AEA-401
     
    Measuring Range :
    HC: 0~10000×10-6 (ppm)vol;
    CO: 0~10×10-2 (%)vol
    CO2: 0~20×10-2 (%)vol 
    O2: 0~25×10-2 (%)vol
    Lambda: 0.50~3.00 
    COcor: 0~10×10-2(%)vol
    Stability : Moment drift ≤±3%; Repeatability ≤±2%
    Size (WxDxH)(mm) : 420×310×170
  • Automobile Exhaust Analyzer AEA-501
    Model : AEA-501
     
    Measuring Range :
    HC: 0~10000×10-6(ppm)vol
    CO: 0~10×10-2(%)vol
    CO2: 0~20×10-2(%)vol
    O2: 0~25×10-2(%)vol
    NOx: 0~5000×10-6(ppm)vol
    Lambda: 0.50~3.00
    COcor: 0~10×10-2(%)vol
    Stability : Moment drift ≤±3%; Repeatability ≤±2%
    Size (WxDxH)(mm) : 420×310×170
  • Portable Dust Detector
    Model : DD-P1B
     
    Detection Method : Pump suction
    Detection Principle : Laser
    Resolution : 1μmg/m3; 1mg/m3
    Sampling Time : 1 minutes
    Size(W×D×H)(mm): 230x130x43
    With its fast sensor response time, the dust detector monitors the concentration and size of airborne dust in real time.
  • Autosampler AS-200
    Model : AS-200

    Sample Type : Solid or Suspension liquid sample
    Measurement Range(mg) : 0.1-30.0
    Analysis Parameter : TC, TIC, TOC (TC-IC)
    Shipping Size(WxDxH)(mm) : 870x650x530
    Total Organic Carbon measures the amount of organic contamination within a sample. The TOC meter supports a wide range of samples and has advanced operability.
  • Portable Mercury Detector
    Model : PMD-A2

    Measuring Range : 0-1.0mg/L
    Minimum Indication : 0.001mg/L
    Repeatability : ≤2%
    Accuracy : ≤±5%FS
    With its portable design, this detector offers easy mobility and can be used in various locations for real-time monitoring.
Contact us

About Company​​​​​​​

As a professional lab and medical equipment manufacturer, Scitek Global is certified by ISO 9001, ISO 13485, ISO 45001 and ISO 14001. Almost all our products are certified by ETL, CE and FDA .

Scitek Global looks forward to establishing cooperation with more distributors all over the world, and working together to create greater customer value.

Quick Links

Contact Us
Scitek Global Co.,Ltd
  No. 7000 Jingshi Road, Jinan City, Shandong Province, China
/  +86-531-82893797
  Inquiry: info@scitekglobal.com
 

9999 Bellaire Blvd Ste 505, Houston, TX 77036, United States
  +1 (915) 4126735
info@scitekglobal.net
 
Copyright © 2023 Scitek Global Co., Ltd. All rights reserved.  Sitemap  Privacy Policy