Application:
The Microvolume UV-Vis Spectrophotometer is designed for the rapid and accurate quantification of microvolumes in genomics, proteomics, molecular biology, biotechnology, pharmaceuticals and life sciences research. The instrument also includes a built-in fluorescence module, capable of measuring fluorescence intensity, supporting Ion Sphere mode, and providing customizable options like excitation/emission light sources and fluorescence kinetics. Perfect for high-throughput labs and those requiring small sample volumes, it ensures accurate results with minimal sample waste.
Advantage:
1. Output port: It has 2 USB-A interfaces, 1 Type C interface, 1 HDMI, and 1 Ethernet port, which can be used to connect with various devices such as mice, keyboards, desktop computers, etc;
2. Equipped with a one click function to export scanned detection results spectra;
3. Can export various forms of detection reports;
4. Fluorescence detection range: 5 orders of magnitude;
5. Fluorescence detection has a custom standard curve module, which can be more freely compatible with more reagent kits and experimental methods;
6. Fluorescence detection has a kinetic module that can perform fluorescence kinetic detection and draw kinetic curves;
7. The colloidal gold module has a unique automatic peak detection function, which can automatically search for the characteristic wavelengths of colloidal gold with different particle sizes;
8. The standard curve has multiple fitting methods to meet diverse experimental needs;
Specification:
| Model | SP-MUV5800I | SP-MUV5800C | SP-MUV5800 | |
| Performance Parameter | Light Source | Longevity lifeline xenon flashing light (10⁹ times) | ||
| Detector | 2048 (coms) linear image sensor | |||
| Detection Wavelength Range | 190–850 nm | |||
| Xenon Lamp Photometric Range | 185–2000 nm | |||
| Wavelength Accuracy | ±1 nm | |||
| Wavelength Resolution | 2 nm (FWHM at Hg 254 nm) | |||
| Accuracy of Absorbance | 1% (0.988 absorbance at 257 nm) | |||
| Monitor | 10.1-inch touch screen, multi-point capacitive touch screen | |||
| Detection Time | Less than 3 seconds | |||
| Optical Path | Ultra trace mode 1, 0.4, 0.1, 0.04, 0.02 mm (optical path automatic conversion) | Ultra trace mode 1, 0.4, 0.1, 0.04, 0.02 mm (optical path automatic conversion) | ||
| Cuvette mode 10, 5, 2, 1 mm | ||||
| Volume Requirements | Ultra trace 0.3–2 μL; Cuvette ≥ 1000 μL (10 mm optical path); | Ultra trace 0.3–2 μL | ||
| Range of Absorbance | Ultra trace mode 0–800 Abs (equivalent to 10mm optical path) | Ultra trace mode 0–800 Abs (equivalent to 10 mm optical path) | ||
| Cuvette mode 0–16 Abs (equivalent to 10 mm optical path) | ||||
| Concentration Measurement Range | Ultra trace: 2–40000 ng/μL (dsDNA); 0.06–1194 mg/mL (BSA); 0.03–584 mg/mL (IgG); 0.02–03 mg/mL (Lysozyme); Cuvette (10 mm): 0.2–80 ng/μL (dsDNA); 0.006–2.38 mg/mL (BSA); 0.003–1.16 mg/mL (IgG); 0.002–0.61 mg/mL (Lysozyme); | Ultra trace: 2–40000 ng/μL (dsDNA); 0.06–1194 mg/mL (BSA); 0.03–584 mg/mL (IgG); 0.02–303 mg/mL (Lysozyme); | ||
| Pollutant Identification Function | Yes | - | ||
| Fluorescent Module | Light Source | Blue LED light, red LED light | - | - |
| Excitation Filter | Blue excitation at 430–495 nm, red excitation at 590–640nm | - | - | |
| Emission Filter | Green emission 510–580 nm, red emission 660–725 nm | - | - | |
| Detector | Photodiode (320–1100 nm) | - | - | |
| Sample Flux | 1 piece | - | - | |
| Sample Dosage | 1–20 μL | - | - | |
| Tube Type | 0.5 mL PCR tube | - | - | |
| Tube Sampling Volume | ≥100 μL | - | - | |
| Warm-Up Time | No preheating required | - | - | |
| Measurement Speed | 3s/tube | - | - | |
| Linear | R²≥0.995 | - | - | |
| Linear Range | 5 orders of magnitude | - | - | |
| Built in reagent calculator to calculate the required amount of dye and buffer solution for the working solution | - | - | ||
| Equipped with a fluorescence meter mode, it can directly measure the fluorescence intensity of the sample | - | - | ||
| Equipped with lon Sphere mode | - | - | ||
| Including fluorescence standard curve module, allowing for free selection of excitation and emission light sources, curve type, standard volume, and total reagent volume | - | - | ||
| Including fluorescence kinetics module, customizable delay time, interval time, and detection frequency for up to 5 stages. | - | - | ||
| Optional Function | Mixing Function | - | Optional | Optional |
| Print Function | Optional | Optional | Optional | |
| Liquid Column Monitoring Function | Optional | Optional | Optional | |
| Audit Tracking Function | Optional | Optional | Optional | |
| External Size (W×D×H) | 200×300×200 mm | |||
| Shipping Size (W×D×H) | 360×290×330 mm | |||
| N.W/G.W. | 3.5 / 4.5 kg | |||
Application:
The Microvolume UV-Vis Spectrophotometer is designed for the rapid and accurate quantification of microvolumes in genomics, proteomics, molecular biology, biotechnology, pharmaceuticals and life sciences research. The instrument also includes a built-in fluorescence module, capable of measuring fluorescence intensity, supporting Ion Sphere mode, and providing customizable options like excitation/emission light sources and fluorescence kinetics. Perfect for high-throughput labs and those requiring small sample volumes, it ensures accurate results with minimal sample waste.
Advantage:
1. Output port: It has 2 USB-A interfaces, 1 Type C interface, 1 HDMI, and 1 Ethernet port, which can be used to connect with various devices such as mice, keyboards, desktop computers, etc;
2. Equipped with a one click function to export scanned detection results spectra;
3. Can export various forms of detection reports;
4. Fluorescence detection range: 5 orders of magnitude;
5. Fluorescence detection has a custom standard curve module, which can be more freely compatible with more reagent kits and experimental methods;
6. Fluorescence detection has a kinetic module that can perform fluorescence kinetic detection and draw kinetic curves;
7. The colloidal gold module has a unique automatic peak detection function, which can automatically search for the characteristic wavelengths of colloidal gold with different particle sizes;
8. The standard curve has multiple fitting methods to meet diverse experimental needs;
Specification:
| Model | SP-MUV5800I | SP-MUV5800C | SP-MUV5800 | |
| Performance Parameter | Light Source | Longevity lifeline xenon flashing light (10⁹ times) | ||
| Detector | 2048 (coms) linear image sensor | |||
| Detection Wavelength Range | 190–850 nm | |||
| Xenon Lamp Photometric Range | 185–2000 nm | |||
| Wavelength Accuracy | ±1 nm | |||
| Wavelength Resolution | 2 nm (FWHM at Hg 254 nm) | |||
| Accuracy of Absorbance | 1% (0.988 absorbance at 257 nm) | |||
| Monitor | 10.1-inch touch screen, multi-point capacitive touch screen | |||
| Detection Time | Less than 3 seconds | |||
| Optical Path | Ultra trace mode 1, 0.4, 0.1, 0.04, 0.02 mm (optical path automatic conversion) | Ultra trace mode 1, 0.4, 0.1, 0.04, 0.02 mm (optical path automatic conversion) | ||
| Cuvette mode 10, 5, 2, 1 mm | ||||
| Volume Requirements | Ultra trace 0.3–2 μL; Cuvette ≥ 1000 μL (10 mm optical path); | Ultra trace 0.3–2 μL | ||
| Range of Absorbance | Ultra trace mode 0–800 Abs (equivalent to 10mm optical path) | Ultra trace mode 0–800 Abs (equivalent to 10 mm optical path) | ||
| Cuvette mode 0–16 Abs (equivalent to 10 mm optical path) | ||||
| Concentration Measurement Range | Ultra trace: 2–40000 ng/μL (dsDNA); 0.06–1194 mg/mL (BSA); 0.03–584 mg/mL (IgG); 0.02–03 mg/mL (Lysozyme); Cuvette (10 mm): 0.2–80 ng/μL (dsDNA); 0.006–2.38 mg/mL (BSA); 0.003–1.16 mg/mL (IgG); 0.002–0.61 mg/mL (Lysozyme); | Ultra trace: 2–40000 ng/μL (dsDNA); 0.06–1194 mg/mL (BSA); 0.03–584 mg/mL (IgG); 0.02–303 mg/mL (Lysozyme); | ||
| Pollutant Identification Function | Yes | - | ||
| Fluorescent Module | Light Source | Blue LED light, red LED light | - | - |
| Excitation Filter | Blue excitation at 430–495 nm, red excitation at 590–640nm | - | - | |
| Emission Filter | Green emission 510–580 nm, red emission 660–725 nm | - | - | |
| Detector | Photodiode (320–1100 nm) | - | - | |
| Sample Flux | 1 piece | - | - | |
| Sample Dosage | 1–20 μL | - | - | |
| Tube Type | 0.5 mL PCR tube | - | - | |
| Tube Sampling Volume | ≥100 μL | - | - | |
| Warm-Up Time | No preheating required | - | - | |
| Measurement Speed | 3s/tube | - | - | |
| Linear | R²≥0.995 | - | - | |
| Linear Range | 5 orders of magnitude | - | - | |
| Built in reagent calculator to calculate the required amount of dye and buffer solution for the working solution | - | - | ||
| Equipped with a fluorescence meter mode, it can directly measure the fluorescence intensity of the sample | - | - | ||
| Equipped with lon Sphere mode | - | - | ||
| Including fluorescence standard curve module, allowing for free selection of excitation and emission light sources, curve type, standard volume, and total reagent volume | - | - | ||
| Including fluorescence kinetics module, customizable delay time, interval time, and detection frequency for up to 5 stages. | - | - | ||
| Optional Function | Mixing Function | - | Optional | Optional |
| Print Function | Optional | Optional | Optional | |
| Liquid Column Monitoring Function | Optional | Optional | Optional | |
| Audit Tracking Function | Optional | Optional | Optional | |
| External Size (W×D×H) | 200×300×200 mm | |||
| Shipping Size (W×D×H) | 360×290×330 mm | |||
| N.W/G.W. | 3.5 / 4.5 kg | |||