PCR cabinet are designed to reduce the risk of contamination while performing Polymerase Chain Reaction (PCR) experiments, it direct HEPA-filtered air downward over the work area to provide ISO Class 5 (formerly Class 100) conditions and protect your work during preparatory procedures and amplifications.
Model | PCR-800 | |
---|---|---|
External Size (WxDxH)(mm) | 710 x 680 x 1050 (Without Base Stand) 710 x 680 x 1680 ( With Base Stand) | |
Internal Size (WxDxH)(mm) | 610x590x625 | |
Work Surface Height | 750mm | |
Control System | Display | Microprocessor controller with LCD display, display the operating status of each function |
Interlock | Front sliding sash interlock with fan and UV lamp | |
Life Indicator | HEPA filter and UV life indicators facilitate a timely replacement plan | |
Airflow System | Airflow Velocity | 0.2~0.5m/s, Speed adjustable |
Air filtration System | Pre-Filter | 1pcs, Polyester fiber,washable |
HEPA Filter | 1 pcs, Efficiency: > 99.995% at particle size of 0.3μm | |
Cleanliness Grade | ISO Class 5 (formerly Class 100) | |
Partial air circulation | Perforations at the back wall of the work zone which are designed to eliminate air turbulence and the possibility of dead air corners in the work zone. | |
Cabinet Construction | Main Body | Electro-Galvanized steel with antimicrobial powder coating |
Work Surface | 304 Stainless steel, an angled front, rounded work surface front edge | |
Front Window | Manual sliding sash: 5 mm UV resistant tempered glass | |
Electrical System | UV Lamp | 10W×2 |
With timing function from 0 to 999 minutes Interlock with front sliding sash. Emission of 253.7 nanometers for best sterilization effect. | ||
LED Lamp | 8W×2 | |
Consumption | 149W (Not include socket loading power consumption) | |
Power Supply | AC220V±10%, 50/60HZ; 110V±10%, 60Hz | |
Illumination | ≥500Lux | |
Sound Emission | ≤62dB(A) | |
Standard Accessory | 1. LED Lamp×2; 2. UV Lamp×2; 3. Waterproof Socket×1; 4. Shelves with IV Bar | |
Optional Accessory | 1. Base stand; 2. Gas Tap | |
Net Weight | 80kg (Without base stand), 130kg (With base stand) | |
Gross Weight | 115kg (Without base stand), 165kg (With base stand) | |
Shipping Size (W×D×H)(mm) | 920x855x1190 | |
Shipping Volume | 0.94m³ |
Safety Performance:
Front sliding sash interlock with fan and UV lamp.
Front sash and side windows are made of UV-resistant tempered glass.
The host and sockets have independent capacitors to prevent current overload.
Humanized design:
Standard shelves with IV bar.
Memory function in case of power-failure.
HEPA filter and UV life indicators facilitate a timely replacem ent plan.
Easy-to-change pre-filter installed could extend the HEPA filter’s life time.
Equipped with temperature sensor to show the real temperature during operation.
Waterproof socket provide convenience for small instruments to be used in the operating area.
Perforations at the back wall of the work zone which are designed to eliminate air turbulence and the possibility of dead air corners in the work zone.
PCR cabinet adopts vertical laminar flow technology, providing clean airflow through HEPA high efficiency filter to prevent outside contamination from entering the experimental area. The bench is equipped with a UV sterilization lamp, which can effectively eliminate residual DNA and reduce the risk of cross-contamination.
Transparent shield ensures the visibility of the experiment and protects the operator at the same time. Built-in LED lighting and humanized touch panel make operation more convenient. Suitable for molecular biology, medical testing and gene amplification experiments.
1. Difference between dead-air PCR cabinet and Scitek PCR cabinets?
Dead-air PCR cabinet are non-ventilated enclosure with dead-air inside the work zone. Scitek PCR cabinets provide HEPA-filtered vertical laminar airflow to the work zone.
2. Can PCR cabinet be used when working with microorganism?
No. PCR cabinets do not provide user protection and cannot be used with infectious materials. These are mainly used for Polymerase Chain Reaction (PCR) experiments, such as PCR master mix and reagent preparation and amplification
3. Difference between Scitek vertical laminar flow cabinet and PCR cabinet?
Both vertical laminar flow cabinets and PCR cabinets provide ISO Class 5 (formerly Class 100) conditions in the work zone for the sample protection. PCR cabinet have standard shelves with IV bar for more convenience of PCR preparation and amplification work.
PCR cabinet are designed to reduce the risk of contamination while performing Polymerase Chain Reaction (PCR) experiments, it direct HEPA-filtered air downward over the work area to provide ISO Class 5 (formerly Class 100) conditions and protect your work during preparatory procedures and amplifications.
Model | PCR-800 | |
---|---|---|
External Size (WxDxH)(mm) | 710 x 680 x 1050 (Without Base Stand) 710 x 680 x 1680 ( With Base Stand) | |
Internal Size (WxDxH)(mm) | 610x590x625 | |
Work Surface Height | 750mm | |
Control System | Display | Microprocessor controller with LCD display, display the operating status of each function |
Interlock | Front sliding sash interlock with fan and UV lamp | |
Life Indicator | HEPA filter and UV life indicators facilitate a timely replacement plan | |
Airflow System | Airflow Velocity | 0.2~0.5m/s, Speed adjustable |
Air filtration System | Pre-Filter | 1pcs, Polyester fiber,washable |
HEPA Filter | 1 pcs, Efficiency: > 99.995% at particle size of 0.3μm | |
Cleanliness Grade | ISO Class 5 (formerly Class 100) | |
Partial air circulation | Perforations at the back wall of the work zone which are designed to eliminate air turbulence and the possibility of dead air corners in the work zone. | |
Cabinet Construction | Main Body | Electro-Galvanized steel with antimicrobial powder coating |
Work Surface | 304 Stainless steel, an angled front, rounded work surface front edge | |
Front Window | Manual sliding sash: 5 mm UV resistant tempered glass | |
Electrical System | UV Lamp | 10W×2 |
With timing function from 0 to 999 minutes Interlock with front sliding sash. Emission of 253.7 nanometers for best sterilization effect. | ||
LED Lamp | 8W×2 | |
Consumption | 149W (Not include socket loading power consumption) | |
Power Supply | AC220V±10%, 50/60HZ; 110V±10%, 60Hz | |
Illumination | ≥500Lux | |
Sound Emission | ≤62dB(A) | |
Standard Accessory | 1. LED Lamp×2; 2. UV Lamp×2; 3. Waterproof Socket×1; 4. Shelves with IV Bar | |
Optional Accessory | 1. Base stand; 2. Gas Tap | |
Net Weight | 80kg (Without base stand), 130kg (With base stand) | |
Gross Weight | 115kg (Without base stand), 165kg (With base stand) | |
Shipping Size (W×D×H)(mm) | 920x855x1190 | |
Shipping Volume | 0.94m³ |
Safety Performance:
Front sliding sash interlock with fan and UV lamp.
Front sash and side windows are made of UV-resistant tempered glass.
The host and sockets have independent capacitors to prevent current overload.
Humanized design:
Standard shelves with IV bar.
Memory function in case of power-failure.
HEPA filter and UV life indicators facilitate a timely replacem ent plan.
Easy-to-change pre-filter installed could extend the HEPA filter’s life time.
Equipped with temperature sensor to show the real temperature during operation.
Waterproof socket provide convenience for small instruments to be used in the operating area.
Perforations at the back wall of the work zone which are designed to eliminate air turbulence and the possibility of dead air corners in the work zone.
PCR cabinet adopts vertical laminar flow technology, providing clean airflow through HEPA high efficiency filter to prevent outside contamination from entering the experimental area. The bench is equipped with a UV sterilization lamp, which can effectively eliminate residual DNA and reduce the risk of cross-contamination.
Transparent shield ensures the visibility of the experiment and protects the operator at the same time. Built-in LED lighting and humanized touch panel make operation more convenient. Suitable for molecular biology, medical testing and gene amplification experiments.
1. Difference between dead-air PCR cabinet and Scitek PCR cabinets?
Dead-air PCR cabinet are non-ventilated enclosure with dead-air inside the work zone. Scitek PCR cabinets provide HEPA-filtered vertical laminar airflow to the work zone.
2. Can PCR cabinet be used when working with microorganism?
No. PCR cabinets do not provide user protection and cannot be used with infectious materials. These are mainly used for Polymerase Chain Reaction (PCR) experiments, such as PCR master mix and reagent preparation and amplification
3. Difference between Scitek vertical laminar flow cabinet and PCR cabinet?
Both vertical laminar flow cabinets and PCR cabinets provide ISO Class 5 (formerly Class 100) conditions in the work zone for the sample protection. PCR cabinet have standard shelves with IV bar for more convenience of PCR preparation and amplification work.