| Availability: | |
|---|---|
| Quantity: | |
Nano Prime UV-FL Series features a three-in-one architecture, integrating micro-volume, cuvette, and fluorescence modes, enabling direct measurement of dsDNA at ultra-high concentrations (2–45,000 ng/μL) without the need for dilution. SCITEK Nano Prime UV-FL Series features an exclusive open-design light intensity diagnostic module allows for user-performed maintenance, combined with intelligent contaminant correction and comprehensive audit trail capabilities, it serves as an essential, multifunctional core analytical tool for modern labs.
Smart Optical Monitoring | 3-in-1 versatility |
|
|
1. 8" to 10.1" touch screen ,offering smooth and intuitive operation.
2. 3-in-1 versatility: micro-volume, cuvette, and fluorescence all in one.
3. Open-architecture light intensity diagnosis and compensation module allows users to read the optical system's real-time energy distribution and perform precise adjustments.(Complete autonomy over maintenance).
4. Ultra-trace mode supports intelligent automatic switching between 5 optical path and free selection of fixed optical path, and also equipped with a single-channel cuvette featuring an adjustable path length.
5. Dual-channel full-wavelength detection for micro volume and cuvette mode from 185–930 nm, a single measurement time≤ 3 s.
6. Extended detection range capable of measuring 2–45000 ng/μL (dsDNA) and 0.06–1343 mg/mL (BSA).
7. Exceptional linear range with 0–800 Abs (10 mm equivalent) for microvolume and 0–16 Abs for cuvettes.
8. Automatically and intelligently identifies common contaminants in samples, providing contamination alerts, contaminant type identification, and correction of raw concentration results. (only for NP-5800FL and NP-5900FL).
9. Capable of providing full audit trail functionality and a hierarchical permission management system to ensure data traceability.
Nucleic Acid Analysis: dsDNA, ssDNA, RNA, Oligos, and gene chips
Protein Quantification: Protein assay & purity analysis (260/280 ratio). BCA, Bradford, Lowry, and Pierce 660.
Integrated Reagent Calculator (Fluorescence Mode): Automatically calculates dye and buffer dosages, compatible with various reagent kits and experimental protocols.
Quantification and Analysis: UV and fluorescence channels both feature powerful kinetic capabilities, supporting up to five customizable detection stages and multiple fitting methods to meet diverse quantitative needs.
Extended Applications: Colloidal gold analysis, microarray application, OD600 Cell fluid module.
| Model | NP-5600FL | NP-5800FL | NP-5900FL | |
| Display | 8" touch screen | 10.1" touch screen | ||
| Light Source | Longevity lifeline xenon flashing light (10⁹ times) | |||
| Volume Requirement | Ultra trace: 0.3–2 μL | |||
| Wavelength Range | 185–930 nm (Ultra Trace and Cuvette) | |||
| Detector | 3864 Element Linear Silicon CCD Array | 2048-element CMOS Linear Image Sensor | ||
| Ultra Trace Optical Path | 1, 0.2, 0.1, 0.03, 0.02 mm (Both Automatic and Adjustable) | 1, 0.4, 0.1, 0.04, 0.02 mm (Both Automatic and Adjustable) | 1, 0.4, 0.1, 0.04, 0.01 mm (Both Automatic and Adjustable) | |
| Cuvette Optical Path | Adjustable: 10, 5, 2, 1 mm | |||
| Concentration Measurement Range | 2–40000 ng/µL (dsDNA), 0.06–1194 mg/mL (BSA) | 2–45000 ng/µL (dsDNA), 0.06–1343 mg/mL (BSA) | ||
| Wavelength Accuracy and Absorbance Accuracy | ±1 nm, 0.002 Abs | |||
| Detection Time | Less than 3 seconds | |||
| Spectral Resolution (Bandwidth) | 2 nm (FWHM at Hg 546 nm) | |||
| Detection Repeatability | 0.002 A (1 mm optical path) or 1% CV | |||
| Pollutant Identification Function | No | Yes | Yes | |
| Fluorescent Module | Light Source | Blue LED light, Red LED light (Standard); UV LED light, Green LED (Optional); | Longevity lifeline xenon flashing light (10⁹ times) | |
| Detector | Photodiode | |||
| Linear | R² ≥0.995 | |||
| Sample Tube | 0.5 mL PCR Tube (1 Sample position) | |||
| Sample Volume | ≥1μL (Signal intensity dependent) | |||
| Measurement Speed | 3s/Tube | |||
| Built-in Reagent Calculator | Yes, calculates required dyes and buffers | |||
| Fluorometer Mode | Yes | |||
| Ion Sphere Mode | Yes | |||
| Standard Curve Module | Yes, flexibly choose Ex/Em light sources | |||
| Fluorescence Kinetics Module | Yes, up to 5 stages of delay/interval/test | |||
| Optional Function | Cuvette Stirring Function | ● | ● | ● |
| Print Function | ● | ● | ● | |
| Liquid Column Monitoring Function | × | ● | ● | |
| Audit Tracking Function | × | ● | ● | |
| Supported Language | Chinese, English, French, German, Arabic, Spanish, Russian, Japanese, and Korean (Language can be customized) | |||
| Interface | 2 USB-A ports, 1 Type-C port, 1 HDMI port, and 1 Ethernet port | |||
| Data Management | Supports USB flash drive data output, Bluetooth, and Wi-Fi connectivity | |||
| Power Supply | AC 100–240V, 50/60Hz | |||
| External Size (W×D×H) | 200×300×200 mm | |||
| Shipping Size (W×D×H) | 360×290×330 mm | |||
| N.W/G.W. | 3.5/4.5 kg | |||
A: Traditional spectrophotometers treat the light source as a "black box," necessitating expensive manufacturer maintenance once aging occurs. In contrast, SCITEK Nano Prime UV-FL Series feature a revolutionary, user-controlled module for light intensity diagnostics and compensation.
Users or lab administrators can directly view the optical system's real-time energy distribution via the software interface. Built-in software tools allow for manual fine-tuning and boosting of light intensity—eliminating the need for downtime or costly manufacturer calibrations—while extending the light source's lifespan by over 40%.
A: With SCITEK Nano Prime UV-FL Series , Users can seamlessly switch between rapid micro-volume droplet analysis, traditional cuvette-based kinetic analysis, and high-sensitivity fluorescence quantitation on a single instrument, thereby significantly saving laboratory space and optimizing procurement budgets.
A: It supports dual modes. The system can automatically switch the optical path based on sample concentration, or you can manually lock the pathlength to ensure strict SOP consistency.
NanoPrime UV-FLSeries-Beyond Measurement, Empower Discovery!