You are here: Home » Products » Spectrophotometer and Colorimeter » Microvolume UV-Vis Spectrophotometer » Nano Prime UV-FL Series Microvolume UV-Vis Spectrophotometer and Fluorometer

loading

Nano Prime UV-FL Series Microvolume UV-Vis Spectrophotometer and Fluorometer

Model : NP-5600FL; NP-5800FL; NP-5900FL

Volume Requirement : 0.3–2 μL
Detection Wavelength Range : 185–930 nm
Optical Path : Both automatic and adjustable
Detection Mode: Ultra-trace, cuvette and fluorescence
Concentration Measurement Range: 2–45000 ng/μL (dsDNA)
Nano Prime UV-FL Series with open-architecture optics
—Empowering innovation and redefining the performance boundaries of micro-sample analysis, 
Availability:
Quantity:

Nano Prime UV-FL Series Microvolume UV-Vis Spectrophotometer and Fluorometer 

Nano Prime UV-FL Series features a three-in-one architecture, integrating micro-volume, cuvette, and fluorescence modes, enabling direct measurement of dsDNA at ultra-high concentrations (2–45,000 ng/μL) without the need for dilution. SCITEK Nano Prime UV-FL Series features an exclusive open-design light intensity diagnostic module allows for user-performed maintenance, combined with intelligent contaminant correction and comprehensive audit trail capabilities, it serves as an essential, multifunctional core analytical tool for modern labs.

                              Smart Optical Monitoring

                                                     3-in-1 versatility

11

33


Microvolume UV-Vis Spectrophotometer and Fluorometer Core Feature:

1. 8" to 10.1" touch screen ,offering smooth and intuitive operation.

2. 3-in-1 versatility: micro-volume, cuvette, and fluorescence all in one.

3. Open-architecture light intensity diagnosis and compensation module allows users to read the optical system's real-time energy distribution and perform precise adjustments.(Complete autonomy over maintenance).

4. Ultra-trace mode supports intelligent automatic switching between 5 optical path and free selection of fixed optical path, and also equipped with a single-channel cuvette featuring an adjustable path length.

5. Dual-channel full-wavelength detection for micro volume and cuvette mode from 185–930 nm, a single measurement time≤ 3 s.

6. Extended detection range capable of measuring 2–45000 ng/μL (dsDNA) and  0.06–1343 mg/mL (BSA).

7. Exceptional linear range with 0–800 Abs (10 mm equivalent) for microvolume and 0–16 Abs for cuvettes.

8. Automatically and intelligently identifies common contaminants in samples, providing contamination alerts, contaminant type identification, and correction of raw concentration results. (only for NP-5800FL and NP-5900FL).

9. Capable of providing full audit trail functionality and a hierarchical permission management system to ensure data traceability.

  • Comprehensive Application Module Coverage:

  • Nucleic Acid Analysis: dsDNA, ssDNA, RNA, Oligos, and gene chips

  • Protein Quantification: Protein assay & purity analysis (260/280 ratio). BCA, Bradford, Lowry, and Pierce 660.

  • Integrated Reagent Calculator (Fluorescence Mode): Automatically calculates dye and buffer dosages, compatible with various reagent kits and experimental protocols.

  • Quantification and Analysis: UV and fluorescence channels both feature powerful kinetic capabilities, supporting up to five customizable detection stages and multiple fitting methods to meet diverse quantitative needs.

  • Extended Applications: Colloidal gold analysis, microarray application, OD600 Cell fluid module.

Microvolume UV-Vis Spectrophotometer and Fluorometer Specification:


Model NP-5600FL NP-5800FL NP-5900FL
Display 8" touch screen 10.1" touch screen
Light Source Longevity lifeline xenon flashing light (10⁹ times)
Volume Requirement Ultra trace: 0.3–2 μL
Wavelength Range 185–930 nm (Ultra Trace and Cuvette)
Detector 3864 Element Linear Silicon CCD Array 2048-element CMOS Linear  Image Sensor
Ultra Trace Optical Path 1, 0.2, 0.1, 0.03, 0.02 mm (Both Automatic and Adjustable) 1, 0.4, 0.1, 0.04, 0.02 mm (Both Automatic and Adjustable) 1, 0.4, 0.1, 0.04, 0.01 mm (Both Automatic and Adjustable)
Cuvette Optical Path Adjustable: 10, 5, 2, 1 mm
Concentration Measurement Range 2–40000 ng/µL (dsDNA), 0.06–1194 mg/mL (BSA) 2–45000 ng/µL (dsDNA), 0.06–1343 mg/mL (BSA)
Wavelength Accuracy and Absorbance Accuracy ±1 nm, 0.002 Abs
Detection Time Less than 3 seconds
Spectral Resolution (Bandwidth) 2 nm (FWHM at Hg 546 nm)
Detection Repeatability 0.002 A (1 mm optical path) or 1% CV
Pollutant Identification Function No Yes Yes
Fluorescent Module Light Source Blue LED light, Red LED light (Standard);
UV LED light, Green LED (Optional);
Longevity lifeline xenon flashing light (10⁹ times)
Detector Photodiode
Linear R² ≥0.995
Sample Tube 0.5 mL PCR Tube (1 Sample position)
Sample Volume ≥1μL (Signal intensity dependent)
Measurement Speed 3s/Tube
Built-in Reagent Calculator Yes, calculates required dyes and buffers
Fluorometer Mode Yes
Ion Sphere Mode Yes
Standard Curve Module Yes, flexibly choose Ex/Em light sources
Fluorescence Kinetics Module Yes, up to 5 stages of delay/interval/test
Optional Function Cuvette Stirring Function
Print Function
Liquid Column Monitoring Function ×
Audit Tracking Function ×
Supported Language Chinese, English, French, German, Arabic, Spanish, Russian, Japanese, and Korean (Language can be customized)
Interface 2 USB-A ports, 1 Type-C port, 1 HDMI port, and 1 Ethernet port
Data Management Supports USB flash drive data output, Bluetooth, and Wi-Fi connectivity
Power Supply AC 100–240V, 50/60Hz
External Size (W×D×H) 200×300×200 mm
Shipping Size (W×D×H) 360×290×330 mm
N.W/G.W. 3.5/4.5 kg


Q1: Why Choose the Microvolume UV-Vis Spectrophotometer and Fluorometer?

A: Traditional spectrophotometers treat the light source as a "black box," necessitating expensive manufacturer maintenance once aging occurs. In contrast, SCITEK Nano Prime UV-FL Series feature a revolutionary, user-controlled module for light intensity diagnostics and compensation.

Users or lab administrators can directly view the optical system's real-time energy distribution via the software interface. Built-in software tools allow for manual fine-tuning and boosting of light intensity—eliminating the need for downtime or costly manufacturer calibrations—while extending the light source's lifespan by over 40%.

Q2:What  can Nano Prime UV-FL offer?

A: With SCITEK Nano Prime UV-FL Series , Users can seamlessly switch between rapid micro-volume droplet analysis, traditional cuvette-based kinetic analysis, and high-sensitivity fluorescence quantitation on a single instrument, thereby significantly saving laboratory space and optimizing procurement budgets.

Q3: How does the micro-volume optical path work?

A: It supports dual modes. The system can automatically switch the optical path based on sample concentration, or you can manually lock the pathlength to ensure strict SOP consistency.


NanoPrime UV-FLSeries-Beyond Measurement, Empower Discovery!

Previous: 
Next: 
Get Quotation/Become Distributor

About Company​​​​​​​

As a professional lab and medical equipment manufacturer, Scitek Global is certified by ISO 9001, ISO 13485, ISO 45001 and ISO 14001. Almost all our products are certified by ETL, CE and FDA .

Scitek Global looks forward to establishing cooperation with more distributors all over the world, and working together to create greater customer value.

Quick Links

Contact Us
Scitek Global Co., Ltd.
  No. 7000 Jingshi Road, Jinan City, Shandong Province, China
/  +86-531-82893797
  Inquiry: info@scitekglobal.com
 
Scitek Global Inc.
9999 Bellaire Blvd Ste 505, Houston, TX 77036, United States
  +1 (915) 4126735
info@scitekglobal.net
 
Copyright © 2023 Scitek Global Co., Ltd. All rights reserved.  Sitemap  Privacy Policy