| Availability: | |
|---|---|
| Quantity: | |
A Precise and Intelligent Analysis Platform
The NanoPrime UV-FL series is a high-performance spectrophotometer integrating ultra-micro detection, fluorescence analysis, intelligent diagnostics, and high scalability, providing accurate and efficient analytical solutions for life sciences, biopharmaceuticals, materials research, and R&D quality control. Featuring superior performance, flexible application expansion and a user-friendly design, NanoPrime UV-FL series aims to become an essential, multifunctional core analytical tool for laboratories, enhancing the efficiency and reliability of modern laboratories performing analysis on nucleic acids, proteins, cells and various specialised samples.
Dual-channel full-wavelength detection for microvolume and cuvette modes addresses broader absorption spectrum research needs.
Capable of measuring 2–37,500 ng/μL (dsDNA); 0.06–1194 mg/mL (BSA). With 2 nm wavelength resolution and 0.002 Abs absorbance accuracy, it precisely measures concentrations across the entire range from ultra-trace levels to high-concentration samples.
NP-5800FL and NP-5900FL Equipped with an exclusive and advanced intelligent sample detection system that automatically identifies common contaminants in samples (such as proteins, nucleic acids, phenols, guanidine salts, etc.) and provides contamination alerts, type identification, and original concentration result correction functions.
Provides reports on the original concentration, corrected concentration, and contaminant type, fundamentally ensuring sample quality and data accuracy, and helping you obtain optimal experimental results.
Nucleic Acid Analysis: dsDNA, ssDNA, RNA, Oligos, and gene chips
Protein Quantification: Protein assay & purity analysis (260/280 ratio). BCA, Bradford, Lowry, and Pierce 660.
Integrated Reagent Calculator (Fluorescence Mode): Automatically calculates dye and buffer dosages, compatible with various reagent kits and experimental protocols.
Quantification and Analysis: UV and fluorescence channels both feature powerful kinetic capabilities, supporting up to five customizable detection stages and multiple fitting methods to meet diverse quantitative needs.
Extended Applications: Colloidal gold analysis, microarray application, OD600 Cell fluid module.
Detection time < 3 seconds with multi-point capacitive touchscreen available in sizes from 7 to 10.1 inches,offering smooth and intuitive operation.
Features Auto-Zero Function, instantly completes measurement upon lowering the detection arm.
Optional accessories: temperature-controlled cuvette holder, adjustable-speed magnetic stirrer, built-in thermal printer, and sample loading column monitoring system.
Superior Connectivity and Data Output: Equipped with abundant interfaces and Wi-Fi, with a built-in hotspot, enabling convenient data transfer and multi-screen collaboration. One-click export of detection spectra and professional reports in various formats significantly improves work efficiency.
Comprehensive data integrity support: Capable of providing full audit trail functionality and a hierarchical permission management system to ensure data traceability.
Model | NP-5600FL | NP-5800FL | NP-5900FL | |
Light Source | Longevity lifeline xenon flashing light (10⁹ times) | |||
Detector | 3864 Element Linear Silicon CCD Array | 2048-element CMOS Linear Image Sensor | ||
Volume Requirements | Ultra trace: 0.3–2 μL | |||
Detection Wavelength Range | 220–800 nm | 200–850 nm | ||
Spectral Resolution (Bandwidth) | 2 nm (FWHM at Hg 546 nm) | |||
Wavelength Accuracy | ±1 nm | |||
Absorbance accuracy | 0.002 Abs | |||
Detecting repeatability | 0.002 A (1 mm optical path) or 1% CV | |||
Optical Path | Ultra trace mode: 1, 0.2, 0.1, 0.03, 0.02 mm (optical path automatic conversion) Cuvette mode: 10/5/2/1 mm | Ultra trace mode: 1, 0.4, 0.1, 0.04, 0.02 mm (optical path automatic conversion) Cuvette mode: 10/5/2/1 mm | Ultra trace mode: 1, 0.4, 0.1, 0.04, 0.01 mm (optical path automatic conversion) Cuvette mode: 10/5/2/1 mm | |
Concentration Measurement Range | Ultra trace: 2–30000 ng/μL (dsDNA); 0.06–895 mg/mL (BSA); | Ultra trace: 2–37500 ng/μL (dsDNA); 0.06–1119 mg/mL (BSA); 0.03–547 mg/mL (IgG); 0.02–284 mg/mL (Lysozyme); | Ultra trace:2–40000 ng/μl (dsDNA); 0.06–1194 mg/mL (BSA); 0.03–584 mg/mL (IgG); 0.02–303 mg/mL (Lysozyme); | |
Range of Absorbance | Ultra trace mode 0–600 Abs (equivalent to 10 mm optical path) | Ultra trace mode 0–600 Abs (equivalent to 10 mm optical path) | Ultra trace mode 0–800 Abs (equivalent to 10 mm optical path) | |
Pollutant Identification Function | No | Yes | Yes | |
Fluorescent Module | Light Source | Blue LED light, Red LED light (Standard); UV LED light, Green LED (Optional); | Longevity lifeline xenon flashing light (10⁹ times) | |
Detector | Photodiode | |||
Linear | R² ≥0.995 | |||
Optional Function | Cuvette Stirring Function | ● | ● | ● |
Print Function | ● | ● | ● | |
Liquid Column Monitoring Function | × | ● | ● | |
Audit Tracking Function | × | ● | ● | |
Supported Language | Chinese, English, French, German, Arabic, Spanish, Russian, Japanese, and Korean (Language can be customized) | |||
Data Management | 2 USB-A ports, 1 Type-C port, 1 HDMI port, and 1 Ethernet port, enabling connection to various devices such as mice, keyboards, and desktop computers; Measurement results are automatically saved in spreadsheet mode, and data can be exported via USB; Supports remote control; | |||
Display | 7-inch /8-inch /10.1-inch touch screen multi-point capacitive touch screen | |||
Power Supply | VAC 100–240 V, 50/60 Hz | |||
External Size (W×D×H) | 200×300×200 mm | |||
Shipping Size (W×D×H) | 360×290×330 mm | |||
N.W/G.W. | 3.5/4.5 kg | |||
Enhanced Dynamic Range Detection: Covers samples from trace to high concentrations without dilution.
Intelligent Contamination Correction: Exclusive contaminant identification technology ensures data integrity from the source.
Minimalist operation experience: <3-second detection + auto-zeroing + large touchscreen display, making experiments flow seamlessly.
Unlimited Expansion: Extensive cuvette accessories and temperature-controlled stirring options support advanced applications
NanoPrime UV-FLSeries-Beyond Measurement, Empower Discovery!
For research use only!
A Precise and Intelligent Analysis Platform
The NanoPrime UV-FL series is a high-performance spectrophotometer integrating ultra-micro detection, fluorescence analysis, intelligent diagnostics, and high scalability, providing accurate and efficient analytical solutions for life sciences, biopharmaceuticals, materials research, and R&D quality control. Featuring superior performance, flexible application expansion and a user-friendly design, NanoPrime UV-FL series aims to become an essential, multifunctional core analytical tool for laboratories, enhancing the efficiency and reliability of modern laboratories performing analysis on nucleic acids, proteins, cells and various specialised samples.
Dual-channel full-wavelength detection for microvolume and cuvette modes addresses broader absorption spectrum research needs.
Capable of measuring 2–37,500 ng/μL (dsDNA); 0.06–1194 mg/mL (BSA). With 2 nm wavelength resolution and 0.002 Abs absorbance accuracy, it precisely measures concentrations across the entire range from ultra-trace levels to high-concentration samples.
NP-5800FL and NP-5900FL Equipped with an exclusive and advanced intelligent sample detection system that automatically identifies common contaminants in samples (such as proteins, nucleic acids, phenols, guanidine salts, etc.) and provides contamination alerts, type identification, and original concentration result correction functions.
Provides reports on the original concentration, corrected concentration, and contaminant type, fundamentally ensuring sample quality and data accuracy, and helping you obtain optimal experimental results.
Nucleic Acid Analysis: dsDNA, ssDNA, RNA, Oligos, and gene chips
Protein Quantification: Protein assay & purity analysis (260/280 ratio). BCA, Bradford, Lowry, and Pierce 660.
Integrated Reagent Calculator (Fluorescence Mode): Automatically calculates dye and buffer dosages, compatible with various reagent kits and experimental protocols.
Quantification and Analysis: UV and fluorescence channels both feature powerful kinetic capabilities, supporting up to five customizable detection stages and multiple fitting methods to meet diverse quantitative needs.
Extended Applications: Colloidal gold analysis, microarray application, OD600 Cell fluid module.
Detection time < 3 seconds with multi-point capacitive touchscreen available in sizes from 7 to 10.1 inches,offering smooth and intuitive operation.
Features Auto-Zero Function, instantly completes measurement upon lowering the detection arm.
Optional accessories: temperature-controlled cuvette holder, adjustable-speed magnetic stirrer, built-in thermal printer, and sample loading column monitoring system.
Superior Connectivity and Data Output: Equipped with abundant interfaces and Wi-Fi, with a built-in hotspot, enabling convenient data transfer and multi-screen collaboration. One-click export of detection spectra and professional reports in various formats significantly improves work efficiency.
Comprehensive data integrity support: Capable of providing full audit trail functionality and a hierarchical permission management system to ensure data traceability.
Model | NP-5600FL | NP-5800FL | NP-5900FL | |
Light Source | Longevity lifeline xenon flashing light (10⁹ times) | |||
Detector | 3864 Element Linear Silicon CCD Array | 2048-element CMOS Linear Image Sensor | ||
Volume Requirements | Ultra trace: 0.3–2 μL | |||
Detection Wavelength Range | 220–800 nm | 200–850 nm | ||
Spectral Resolution (Bandwidth) | 2 nm (FWHM at Hg 546 nm) | |||
Wavelength Accuracy | ±1 nm | |||
Absorbance accuracy | 0.002 Abs | |||
Detecting repeatability | 0.002 A (1 mm optical path) or 1% CV | |||
Optical Path | Ultra trace mode: 1, 0.2, 0.1, 0.03, 0.02 mm (optical path automatic conversion) Cuvette mode: 10/5/2/1 mm | Ultra trace mode: 1, 0.4, 0.1, 0.04, 0.02 mm (optical path automatic conversion) Cuvette mode: 10/5/2/1 mm | Ultra trace mode: 1, 0.4, 0.1, 0.04, 0.01 mm (optical path automatic conversion) Cuvette mode: 10/5/2/1 mm | |
Concentration Measurement Range | Ultra trace: 2–30000 ng/μL (dsDNA); 0.06–895 mg/mL (BSA); | Ultra trace: 2–37500 ng/μL (dsDNA); 0.06–1119 mg/mL (BSA); 0.03–547 mg/mL (IgG); 0.02–284 mg/mL (Lysozyme); | Ultra trace:2–40000 ng/μl (dsDNA); 0.06–1194 mg/mL (BSA); 0.03–584 mg/mL (IgG); 0.02–303 mg/mL (Lysozyme); | |
Range of Absorbance | Ultra trace mode 0–600 Abs (equivalent to 10 mm optical path) | Ultra trace mode 0–600 Abs (equivalent to 10 mm optical path) | Ultra trace mode 0–800 Abs (equivalent to 10 mm optical path) | |
Pollutant Identification Function | No | Yes | Yes | |
Fluorescent Module | Light Source | Blue LED light, Red LED light (Standard); UV LED light, Green LED (Optional); | Longevity lifeline xenon flashing light (10⁹ times) | |
Detector | Photodiode | |||
Linear | R² ≥0.995 | |||
Optional Function | Cuvette Stirring Function | ● | ● | ● |
Print Function | ● | ● | ● | |
Liquid Column Monitoring Function | × | ● | ● | |
Audit Tracking Function | × | ● | ● | |
Supported Language | Chinese, English, French, German, Arabic, Spanish, Russian, Japanese, and Korean (Language can be customized) | |||
Data Management | 2 USB-A ports, 1 Type-C port, 1 HDMI port, and 1 Ethernet port, enabling connection to various devices such as mice, keyboards, and desktop computers; Measurement results are automatically saved in spreadsheet mode, and data can be exported via USB; Supports remote control; | |||
Display | 7-inch /8-inch /10.1-inch touch screen multi-point capacitive touch screen | |||
Power Supply | VAC 100–240 V, 50/60 Hz | |||
External Size (W×D×H) | 200×300×200 mm | |||
Shipping Size (W×D×H) | 360×290×330 mm | |||
N.W/G.W. | 3.5/4.5 kg | |||
Enhanced Dynamic Range Detection: Covers samples from trace to high concentrations without dilution.
Intelligent Contamination Correction: Exclusive contaminant identification technology ensures data integrity from the source.
Minimalist operation experience: <3-second detection + auto-zeroing + large touchscreen display, making experiments flow seamlessly.
Unlimited Expansion: Extensive cuvette accessories and temperature-controlled stirring options support advanced applications
NanoPrime UV-FLSeries-Beyond Measurement, Empower Discovery!