| Availability: | |
|---|---|
| Quantity: | |
Traditional micro-volume spectrophotometers typically treat optical performance as a fixed factory-set parameter. SCITEK Nano Prime series features user-controlled optical performance management. With built-in light intensity monitoring and user-adjustable compensation mechanisms, the series ensures long-term measurement stability and reduces the burden of routine maintenance. Offering flexible measurement modes, including automatic pathlength adjustment and user-defined fixed pathlength settings, fully meets the diverse quantification and analysis needs of nucleic acid, protein, and general laboratory research.
Smart Optical Monitoring
Multiple Assay Module
1. Open-architecture light intensity diagnosis and compensation module allows users to read the optical system's real-time energy distribution and perform precise adjustments (Complete autonomy over maintenance).
2. 7 inches touchscreen available in sizes, offering smooth and intuitive operation.
3. Dual-channel full-wavelength detection for micro-volume and cuvette mode from 200–850 nm.
4. Extended detection range capable of measuring 2–15000 ng/µL (dsDNA) and 0.06–400 mg/mL (BSA).
5. Ultra-trace mode supports automatic optical path adjustment and user-defined fixed path length settings to meet diverse research and analysis needs.
Nucleic Acid Analysis: dsDNA, ssDNA, RNA, Oligos, and gene chips
Protein Quantification: Protein assay & purity analysis (260/280 ratio). BCA, Bradford, Lowry, and Pierce 660.
UV analysis: Full wavelength scanning, purity and impurity analysis, kinetic quantification fulfill diverse analytical demands. Embedded sensors and digital image analysis ensure detection integrity.
Extended Applications: Colloidal gold analysis, OD600 Cell fluid module.
| Model | NP-5500-KTM | |
| Display | 7" touch screen | |
| Light Source | Longevity lifeline xenon flashing light (10⁹ times) | |
| Volume Requirement | Ultra trace: 0.3–2 μL | |
| Wavelength Range | 200–850 nm (Ultra Trace and Cuvette) | |
| Detector | 2048-element CMOS Linear Image Sensor | |
| Ultra Trace Optical Path | 1, 0.5, 0.05 mm (Both Automatic and Adjustable) | |
| Cuvette Optical Path | No Cuvette Mode | |
| Concentration Measurement Range | 2–15000 ng/µL (dsDNA), 0.06–400 mg/mL (BSA) | |
| Wavelength and Absorbance Accuracy | ±1 nm, 0.002 Abs | |
| Detection Time | Less than 3 seconds | |
| Spectral Resolution (Bandwidth) | 2 nm (FWHM at Hg 546 nm) | |
| Detection Repeatability | Detecting repeatability: 0.002 A (1 mm optical path) or 1% CV | |
| Pollutant Identification Function | No | |
| Optional Function | Mixing function | × |
| Print function | × | |
| Liquid Column Monitoring Function | × | |
| Audit Tracking Function | × | |
| Supported Language | Chinese, English, French, German, Arabic, Spanish, Russian, Japanese, and Korean (Language can be customized) | |
| Interface | 2 USB-A ports | |
| Data Management | Supports USB flash drive data output, Bluetooth, and Wi-Fi connectivity | |
| Power Supply | AC 100–240 V, 50/60 Hz | |
| External Size (W×D×H) | 200×300×200 mm | |
| Shipping Size (W×D×H) | 360×290×330 mm | |
| N.W/G.W. | 3.5/4.5 kg | |