| Availability: | |
|---|---|
| Quantity: | |
Empowering innovation and redefining the performance boundaries of micro-sample analysis
The Nano Prime series Microvolume UV-Vis Spectrophotometer redefines the precision and efficiency in analytical workflows. Utilizing advanced dual-channel technology and intelligent detection systems, the NanoPrime series seamlessly adapts to diverse research, quality control, and compliance requirements—from academic laboratories to pharmaceutical manufacturing. Whether for nucleic acid/protein quantification, colorimetric analysis, kinetic studies, colloidal gold detection, or other diverse applications, the NanoPrime series delivers reliable, accurate results with a rapid workflow and professional data management.
Dual-channel full-wavelength detection for microvolume and cuvette modes addresses broader absorption spectrum research needs.
With 2 nm wavelength resolution and 0.002 Abs absorbance accuracy, capable of measuring 2–15000/2–30000/2–37500 ng/μL (dsDNA). it precisely measures concentrations across the entire range from ultra-trace levels to high-concentration samples.
NP-5800 and NP-5800C Equipped with an exclusive and advanced intelligent sample detection system that automatically identifies common contaminants in samples (such as proteins, nucleic acids, phenols, guanidine salts, etc.) and provides contamination alerts, type identification, and original concentration result correction functions.
Provides reports on the original concentration, corrected concentration, and contaminant type, fundamentally ensuring sample quality and data accuracy, and helping you obtain optimal experimental results.
Nucleic Acid Analysis: dsDNA, ssDNA, RNA, Oligos, and gene chips
Protein Quantification: Protein assay & purity analysis (260/280 ratio). BCA, Bradford, Lowry, and Pierce 660.
UV analysis: Full wavelength scanning, purity and impurity analysis, kinetic quantification fulfill diverse analytical demands. Embedded sensors and digital image analysis ensure detection integrity.
Extended Applications: Colloidal gold analysis, OD600 Cell fluid module.
Detection time < 3 seconds with multi-point capacitive touchscreen available in sizes from 7 to 10.1 inches,offering smooth and intuitive operation.
Features Auto-Zero Function, instantly completes measurement upon lowering the detection arm.
Optional accessories: temperature-controlled cuvette holder, adjustable-speed magnetic stirrer, built-in thermal printer, and sample loading column monitoring system.
Superior Connectivity and Data Output: Equipped with abundant interfaces, enabling convenient data transfer and multi-screen collaboration. One-click export of detection spectra and professional reports in various formats significantly improves work efficiency.
Comprehensive data integrity support: Capable of providing full audit trail functionality and a hierarchical permission management system to ensure data traceability.
Model | NP-5500 | NP-5500C | NP-5600 | NP-5600C | NP-5800 | NP-5800C | |
Light Source | Longevity lifeline xenon flashing light (10⁹ times) | ||||||
Volume Requirements | Ultra trace: 0.3–2 μL | ||||||
Detector | 2048-element CMOS Linear Image Sensor | 3864 Element Linear Silicon CCD Array | 2048-element CMOS Linear Image Sensor | ||||
Detection Wavelength Range | 200–850 nm | 200–800 nm | 200–850 nm | ||||
Wavelength and Absorbance Accuracy | ±1 nm, 0.002 Abs | ||||||
Spectral Resolution (Bandwidth) | 2 nm (FWHM at Hg 546 nm) | ||||||
Operating System | Win 10 | LINUX | |||||
Monitor | 7-inch high-definition touch screen display | 8-inch touch screen | 10.1-inch touch screen, multi-point capacitive touch screen | ||||
Detection Time | Less than 3 seconds | ||||||
Optical Path | Ultra trace mode: 1, 0.5, 0.05 mm (Three optical path automatic conversion) | Ultra trace mode: 1, 0.2, 0.1, 0.03, 0.02 mm (Five optical path automatic conversion) | Ultra trace mode 1, 0.4, 0.1, 0.04, 0.02 mm (Five optical path automatic conversion) | ||||
No | Cuvette mode: 10/5/2/1 mm | No | Cuvette mode: 10/5/2/1 mm | No | Cuvette mode: 10/5/2/1 mm | ||
| Detecting repeatability | Detecting repeatability: 0.002 A (1 mm optical path) or 1% CV | ||||||
Pollutant Identification Function | Ultra trace: 2–15000 ng/µL (dsDNA); | Ultra trace: 2–30000 ng/μL(dsDNA); 0.06–895 mg/mL(BSA); | Ultra trace: 0.06–1194 mg/mL(BSA); 0.03–584 mg/mL (IgG); 0.02–303 mg/mL (Lysozyme); | ||||
Optional Function | Mixing function | × | × | × | ● | × | ● |
Print function | × | × | ● | ● | ● | ● | |
Liquid Column Monitoring Function | × | × | × | × | ● | ● | |
Audit Tracking Function | × | × | × | × | ● | ● | |
Supported Languages | Chinese, English, French, German, Arabic, Spanish, Russian, Japanese, and Korean; | ||||||
Data Management | Equipped with 2 USB-A ports, Supports USB flash drive data output, Bluetooth, and Wi-Fi connectivity; | Supports USB flash drive data output, Ethernet, Bluetooth, and Wi-Fi connectivity; | |||||
Enhanced Dynamic Range Detection: Covers samples from trace to high concentrations without dilution.
Intelligent Contamination Correction: Exclusive contaminant identification technology ensures data integrity from the source.
Minimalist operation experience: <3-second detection + auto-zeroing + large touchscreen display, making experiments flow seamlessly.
Unlimited Expansion: Extensive cuvette accessories and temperature-controlled stirring options support advanced applications
NanoPrime Series-Beyond Measurement, Empower Discovery!
For research use only!
Empowering innovation and redefining the performance boundaries of micro-sample analysis
The Nano Prime series Microvolume UV-Vis Spectrophotometer redefines the precision and efficiency in analytical workflows. Utilizing advanced dual-channel technology and intelligent detection systems, the NanoPrime series seamlessly adapts to diverse research, quality control, and compliance requirements—from academic laboratories to pharmaceutical manufacturing. Whether for nucleic acid/protein quantification, colorimetric analysis, kinetic studies, colloidal gold detection, or other diverse applications, the NanoPrime series delivers reliable, accurate results with a rapid workflow and professional data management.
Dual-channel full-wavelength detection for microvolume and cuvette modes addresses broader absorption spectrum research needs.
With 2 nm wavelength resolution and 0.002 Abs absorbance accuracy, capable of measuring 2–15000/2–30000/2–37500 ng/μL (dsDNA). it precisely measures concentrations across the entire range from ultra-trace levels to high-concentration samples.
NP-5800 and NP-5800C Equipped with an exclusive and advanced intelligent sample detection system that automatically identifies common contaminants in samples (such as proteins, nucleic acids, phenols, guanidine salts, etc.) and provides contamination alerts, type identification, and original concentration result correction functions.
Provides reports on the original concentration, corrected concentration, and contaminant type, fundamentally ensuring sample quality and data accuracy, and helping you obtain optimal experimental results.
Nucleic Acid Analysis: dsDNA, ssDNA, RNA, Oligos, and gene chips
Protein Quantification: Protein assay & purity analysis (260/280 ratio). BCA, Bradford, Lowry, and Pierce 660.
UV analysis: Full wavelength scanning, purity and impurity analysis, kinetic quantification fulfill diverse analytical demands. Embedded sensors and digital image analysis ensure detection integrity.
Extended Applications: Colloidal gold analysis, OD600 Cell fluid module.
Detection time < 3 seconds with multi-point capacitive touchscreen available in sizes from 7 to 10.1 inches,offering smooth and intuitive operation.
Features Auto-Zero Function, instantly completes measurement upon lowering the detection arm.
Optional accessories: temperature-controlled cuvette holder, adjustable-speed magnetic stirrer, built-in thermal printer, and sample loading column monitoring system.
Superior Connectivity and Data Output: Equipped with abundant interfaces, enabling convenient data transfer and multi-screen collaboration. One-click export of detection spectra and professional reports in various formats significantly improves work efficiency.
Comprehensive data integrity support: Capable of providing full audit trail functionality and a hierarchical permission management system to ensure data traceability.
Model | NP-5500 | NP-5500C | NP-5600 | NP-5600C | NP-5800 | NP-5800C | |
Light Source | Longevity lifeline xenon flashing light (10⁹ times) | ||||||
Volume Requirements | Ultra trace: 0.3–2 μL | ||||||
Detector | 2048-element CMOS Linear Image Sensor | 3864 Element Linear Silicon CCD Array | 2048-element CMOS Linear Image Sensor | ||||
Detection Wavelength Range | 200–850 nm | 200–800 nm | 200–850 nm | ||||
Wavelength and Absorbance Accuracy | ±1 nm, 0.002 Abs | ||||||
Spectral Resolution (Bandwidth) | 2 nm (FWHM at Hg 546 nm) | ||||||
Operating System | Win 10 | LINUX | |||||
Monitor | 7-inch high-definition touch screen display | 8-inch touch screen | 10.1-inch touch screen, multi-point capacitive touch screen | ||||
Detection Time | Less than 3 seconds | ||||||
Optical Path | Ultra trace mode: 1, 0.5, 0.05 mm (Three optical path automatic conversion) | Ultra trace mode: 1, 0.2, 0.1, 0.03, 0.02 mm (Five optical path automatic conversion) | Ultra trace mode 1, 0.4, 0.1, 0.04, 0.02 mm (Five optical path automatic conversion) | ||||
No | Cuvette mode: 10/5/2/1 mm | No | Cuvette mode: 10/5/2/1 mm | No | Cuvette mode: 10/5/2/1 mm | ||
| Detecting repeatability | Detecting repeatability: 0.002 A (1 mm optical path) or 1% CV | ||||||
Pollutant Identification Function | Ultra trace: 2–15000 ng/µL (dsDNA); | Ultra trace: 2–30000 ng/μL(dsDNA); 0.06–895 mg/mL(BSA); | Ultra trace: 0.06–1194 mg/mL(BSA); 0.03–584 mg/mL (IgG); 0.02–303 mg/mL (Lysozyme); | ||||
Optional Function | Mixing function | × | × | × | ● | × | ● |
Print function | × | × | ● | ● | ● | ● | |
Liquid Column Monitoring Function | × | × | × | × | ● | ● | |
Audit Tracking Function | × | × | × | × | ● | ● | |
Supported Languages | Chinese, English, French, German, Arabic, Spanish, Russian, Japanese, and Korean; | ||||||
Data Management | Equipped with 2 USB-A ports, Supports USB flash drive data output, Bluetooth, and Wi-Fi connectivity; | Supports USB flash drive data output, Ethernet, Bluetooth, and Wi-Fi connectivity; | |||||
Enhanced Dynamic Range Detection: Covers samples from trace to high concentrations without dilution.
Intelligent Contamination Correction: Exclusive contaminant identification technology ensures data integrity from the source.
Minimalist operation experience: <3-second detection + auto-zeroing + large touchscreen display, making experiments flow seamlessly.
Unlimited Expansion: Extensive cuvette accessories and temperature-controlled stirring options support advanced applications
NanoPrime Series-Beyond Measurement, Empower Discovery!
For research use only!