The Fully Automatic Biochemistry Analyser is a diagnostic tool used in clinical laboratories, hospitals and research facilities for the accurate and efficient testing of biochemistry. It automates the entire testing process and is suitable for analysing a wide range of clinical samples, including blood, urine and serum. It measures key biomarkers such as enzymes, electrolytes, glucose and lipids, delivering accurate and timely results.
1. Optimal Performance: ideal replacement for semi-automatic chemistry analyzers.
2. Minimal Labor Requirements: designed to reduce the need for manual intervention, allowing for more efficient operations.
3. Independent Mixing Probe: features an independent mixing probe for enhanced accuracy and consistency.
4. Reduced Reagent Usage: reagent consumption is minimized, using only 300µL per test.
5. High Efficiency: fast and efficient processing speeds for improved throughput.
6. User-Friendly Interface: equipped with smart, easy-to-operate software for seamless use.
7. High Accuracy: delivers precise results with minimal operating or random errors.
8. Trusted by Clinics: highly regarded and well-reputed in clinical settings.
9. Advanced Calibration and Re-testing: automatic re-testing feature for samples outside the linearity range or when the sample is insufficient.
Model | BA-260I | BA-260II |
Test Speed | Constant 200 tests/hour | |
Test Principle | Absorbance photometry, immunoturbidimetric | |
Test Methodology | End-point, Fixed-time, Kinetic, Single/Double Reagent Chemistry | |
Calibration Type | Linear/nonlinear multi-points calibration | |
Calibration Model | Single point, Two point, Multiple point, Logitlog, Segment line, Exponential 5p, Polynomial, Poly4, Spline, Logistic | |
Sample Volume | 1.6–50 µL, 0.1 µL step | |
Sample Dilution | Automatic/manual pre-dilution, with dilution ratio up to 1:100 | |
Sample Tray | 40 positions | |
| Reagent Volume | 10–300 µL, 0.1 µL step | |
Reagent Tray | Internal barcode reader, 40 positions for reagents, reagent tray in 24 hour refrigerated compartment (2–8 ℃) | Internal barcode reader, 40 positions for reagents, reagent tray in 24 hour refrigerated compartment (2–8 ℃); |
Reagent/Sample Probe | Liquid level detection, vertical collision protection, inventory checking | |
Probe Cleaning | Automatic washing for interior & exterior/carry over < 0.1% | |
Reaction tray | 60 reusable cuvettes | |
| Reaction volume | 120–300 µL | |
| Reaction time | 10 minutes | |
| Reaction temperature | 37±0.1 ℃ | |
| Optical length of cuvette | 5 mm | |
Mixing Unit | Independent mixing bar | |
Cuvette Washing | Automatic 7-step washing washing system | 8-stage, dual-step automatic rinsing; high-concentration cleaning solutions; |
Optical System | Photometry system: rear spectrophotometry | |
Light source: halogen-tungsten lamp | ||
Wavelength: 340–700 nm, 9 wavelengths (340, 405, 450, 510, 546, 578, 620, 660, 700 nm), precision ±1.5 nm | ||
Absorbance range: 0–3.0 Abs | ||
Resolution: 0.0001 Abs/Automatic dilution and re-test when ABS and Linear out of range | ||
Control Rule | One key calibrator import function westgard multi-rule | |
Analysis Method | End-point, kinetic, two-point, double-reagent, double-wavelength, multi-standard etc, open to various reagents | |
| Operation system | Windows 7 or above | |
Input | RS-232 interface/computer | |
Output | Multi-format printout | |
Interface | RS-232 | |
Temperature | 10–35 ℃ | |
Humidity | ≤90%, no dew | |
Power Supply | 110 /220 V, 350 W | |
Lower Water Consumption | 5 L/H | |
Size (W×D×H)(mm) | 590×420×330 | 640×440×420 |
Packing Size (W×D×H)(mm) | 650×480×580 | 880×550×600 |
N.W/G.W (kg) | 36 /40 | 42/60 |
The Fully Automatic Biochemistry Analyser is a diagnostic tool used in clinical laboratories, hospitals and research facilities for the accurate and efficient testing of biochemistry. It automates the entire testing process and is suitable for analysing a wide range of clinical samples, including blood, urine and serum. It measures key biomarkers such as enzymes, electrolytes, glucose and lipids, delivering accurate and timely results.
1. Optimal Performance: ideal replacement for semi-automatic chemistry analyzers.
2. Minimal Labor Requirements: designed to reduce the need for manual intervention, allowing for more efficient operations.
3. Independent Mixing Probe: features an independent mixing probe for enhanced accuracy and consistency.
4. Reduced Reagent Usage: reagent consumption is minimized, using only 300µL per test.
5. High Efficiency: fast and efficient processing speeds for improved throughput.
6. User-Friendly Interface: equipped with smart, easy-to-operate software for seamless use.
7. High Accuracy: delivers precise results with minimal operating or random errors.
8. Trusted by Clinics: highly regarded and well-reputed in clinical settings.
9. Advanced Calibration and Re-testing: automatic re-testing feature for samples outside the linearity range or when the sample is insufficient.
Model | BA-260I | BA-260II |
Test Speed | Constant 200 tests/hour | |
Test Principle | Absorbance photometry, immunoturbidimetric | |
Test Methodology | End-point, Fixed-time, Kinetic, Single/Double Reagent Chemistry | |
Calibration Type | Linear/nonlinear multi-points calibration | |
Calibration Model | Single point, Two point, Multiple point, Logitlog, Segment line, Exponential 5p, Polynomial, Poly4, Spline, Logistic | |
Sample Volume | 1.6–50 µL, 0.1 µL step | |
Sample Dilution | Automatic/manual pre-dilution, with dilution ratio up to 1:100 | |
Sample Tray | 40 positions | |
| Reagent Volume | 10–300 µL, 0.1 µL step | |
Reagent Tray | Internal barcode reader, 40 positions for reagents, reagent tray in 24 hour refrigerated compartment (2–8 ℃) | Internal barcode reader, 40 positions for reagents, reagent tray in 24 hour refrigerated compartment (2–8 ℃); |
Reagent/Sample Probe | Liquid level detection, vertical collision protection, inventory checking | |
Probe Cleaning | Automatic washing for interior & exterior/carry over < 0.1% | |
Reaction tray | 60 reusable cuvettes | |
| Reaction volume | 120–300 µL | |
| Reaction time | 10 minutes | |
| Reaction temperature | 37±0.1 ℃ | |
| Optical length of cuvette | 5 mm | |
Mixing Unit | Independent mixing bar | |
Cuvette Washing | Automatic 7-step washing washing system | 8-stage, dual-step automatic rinsing; high-concentration cleaning solutions; |
Optical System | Photometry system: rear spectrophotometry | |
Light source: halogen-tungsten lamp | ||
Wavelength: 340–700 nm, 9 wavelengths (340, 405, 450, 510, 546, 578, 620, 660, 700 nm), precision ±1.5 nm | ||
Absorbance range: 0–3.0 Abs | ||
Resolution: 0.0001 Abs/Automatic dilution and re-test when ABS and Linear out of range | ||
Control Rule | One key calibrator import function westgard multi-rule | |
Analysis Method | End-point, kinetic, two-point, double-reagent, double-wavelength, multi-standard etc, open to various reagents | |
| Operation system | Windows 7 or above | |
Input | RS-232 interface/computer | |
Output | Multi-format printout | |
Interface | RS-232 | |
Temperature | 10–35 ℃ | |
Humidity | ≤90%, no dew | |
Power Supply | 110 /220 V, 350 W | |
Lower Water Consumption | 5 L/H | |
Size (W×D×H)(mm) | 590×420×330 | 640×440×420 |
Packing Size (W×D×H)(mm) | 650×480×580 | 880×550×600 |
N.W/G.W (kg) | 36 /40 | 42/60 |