| Model | BA-200E | |
|---|---|---|
| Efficiency Speed | 200 tests/hour | |
| System Functions | Analysis Methods: End-point, kinetic, two-point, double-reagent, double-wavelength, multi-standard etc, open to various reagents | |
| Max reaction Time | 10 minutes | |
| Reaction Volume | 180~400μl | |
| Reaction Cuvettes | 60 pcs reusable plastic cuvettes | |
| Absorbance Range | 0~5.0 Abs | |
| Halogen Light Source Using Time | 2000h | |
| Wavelength | 340-690nm, 9 wavelengths, precision ±1.5nm | |
| Absorbance Range | 0~5.0 Abs | |
| Resolution | 0.0001 Abs | |
| Reaction Temperature | 37±0.1℃ | |
| Temperature Fluctuation | ±0.1℃ | |
| Sizes(W×D×H)(mm) | 548x422x383 | |
| N.W(kg) | ≤23kg | |
| Sample/ Reagents Handling | Sample volume | 1.6-50ul, 0.1μl step |
| Sample Dilution | Automatic/Manual pre-dilution, with dilution ratio up to 1:100 | |
| Reagent Position | 40 pcs | |
| Reagent Volume | 10-500μl, 0.5ul step | |
| Sample/Reagent/Mixing Probe | Automatic liquid level detect, Collision protection function, Probe internal/external washing, Independent mixing probe | |
| 7-Step Auto Cleaning System | Automatic 7-step washing, Hi-tech washing station to ensure accurate results, With low water consumption: 1-2L/H | |
| Calibration | Calibration: Linear/nonlinear multi-points calibration | |
| Re-test: Retest the sample automatically when the result is out of the linearity range or the sample is not sufficient | ||
| Working Condition | Power Supply: 100-240V, 50/60Hz, 300VA | |
| Temperature: 10-35℃ | ||
| Humidity: ≤90%, no dew | ||
| Operation System | Windows 10 or Windows 7 | |
| Input and Output | Input: RS-232 interface/computer | |
| Output: Multi-format printout | ||
| Sample/Reagent Position | ![]() |
| |
| Reaction Cuvettes | ![]() |
| |
| Sample/Reagent/Mixing Probe | ![]() |
| |
| 7-Step Auto Cleaning System | ![]() |
| |
| Intellective software | ![]() |
| |
| Optimum calibration cuvette | ![]() |
| |
| Dynamic and Real-time display of running status | ![]() |
| |
| Automatic dilute and re-test | ![]() |
|
40pcs sample position, Reagent refrigerated function, 40pcs reagent position
Efficiency speed 200 tests/hour
Utility of reagents decreased: 300ul/test
User friendly: Smart and easy-operating software
High Accuracy: Minimal operating/random errors
This auto biochemistry analyzer from Scitek is designed to analyze a variety of test samples. This includes blood, plasma, serum, urine and more. It supports the simultaneous execution of multiple tests and offers a wider range of tests. Greatly simplifies your workflow.
| Model | BA-200E | |
|---|---|---|
| Efficiency Speed | 200 tests/hour | |
| System Functions | Analysis Methods: End-point, kinetic, two-point, double-reagent, double-wavelength, multi-standard etc, open to various reagents | |
| Max reaction Time | 10 minutes | |
| Reaction Volume | 180~400μl | |
| Reaction Cuvettes | 60 pcs reusable plastic cuvettes | |
| Absorbance Range | 0~5.0 Abs | |
| Halogen Light Source Using Time | 2000h | |
| Wavelength | 340-690nm, 9 wavelengths, precision ±1.5nm | |
| Absorbance Range | 0~5.0 Abs | |
| Resolution | 0.0001 Abs | |
| Reaction Temperature | 37±0.1℃ | |
| Temperature Fluctuation | ±0.1℃ | |
| Sizes(W×D×H)(mm) | 548x422x383 | |
| N.W(kg) | ≤23kg | |
| Sample/ Reagents Handling | Sample volume | 1.6-50ul, 0.1μl step |
| Sample Dilution | Automatic/Manual pre-dilution, with dilution ratio up to 1:100 | |
| Reagent Position | 40 pcs | |
| Reagent Volume | 10-500μl, 0.5ul step | |
| Sample/Reagent/Mixing Probe | Automatic liquid level detect, Collision protection function, Probe internal/external washing, Independent mixing probe | |
| 7-Step Auto Cleaning System | Automatic 7-step washing, Hi-tech washing station to ensure accurate results, With low water consumption: 1-2L/H | |
| Calibration | Calibration: Linear/nonlinear multi-points calibration | |
| Re-test: Retest the sample automatically when the result is out of the linearity range or the sample is not sufficient | ||
| Working Condition | Power Supply: 100-240V, 50/60Hz, 300VA | |
| Temperature: 10-35℃ | ||
| Humidity: ≤90%, no dew | ||
| Operation System | Windows 10 or Windows 7 | |
| Input and Output | Input: RS-232 interface/computer | |
| Output: Multi-format printout | ||
| Sample/Reagent Position | ![]() |
| |
| Reaction Cuvettes | ![]() |
| |
| Sample/Reagent/Mixing Probe | ![]() |
| |
| 7-Step Auto Cleaning System | ![]() |
| |
| Intellective software | ![]() |
| |
| Optimum calibration cuvette | ![]() |
| |
| Dynamic and Real-time display of running status | ![]() |
| |
| Automatic dilute and re-test | ![]() |
|
40pcs sample position, Reagent refrigerated function, 40pcs reagent position
Efficiency speed 200 tests/hour
Utility of reagents decreased: 300ul/test
User friendly: Smart and easy-operating software
High Accuracy: Minimal operating/random errors