Model : BA-120; BA-160; BA-220; BA-280; BA-380; BA-480
 
Test Method : 1 point end, 2 point end, Fixed-Time, Kinetics
Machine Type : Random access, open reagent & locked reagent (optional)
Test Principle : Colorimetric method, turbidimetry
Sizes(W×D×H)(mm) : 750x550x490;750x475x535;780x565x1120;
                                    870x690x740;920x650x1120;1110x765x1150;
This biochemistry analyzer is suitable for analysing biochemical indicators in biological samples such as serum and urine to assist doctors in disease diagnosis and treatment monitoring.
Availability:
Quantity:

Fully Automatic Biochemistry Analyzer Specifications:

ModelBA-120BA-160BA-220BA-280BA-380BA-480
Machine TypeRandom access, open reagent & locked reagent (optional)
Test Speed

Constant 120 tests/hour (Mono reagent or double reagent)

Constant 150 tests/hour 

(Mono reagent or double reagent)

Constant 200 tests/hour 

(Mono reagent or double reagent)

Constant 200 tests/hour 

(Mono reagent or double reagent)

Constant 300 tests/hour 

(Mono reagent or double reagent)

Constant 400 tests/hour 

(Mono reagent or double reagent)

Test PrincipleColorimetric method, turbidimetry
Test Method1 point end, 2 point end, Fixed-Time, Kinetics
Calibration TypeLinear & nonlinear
Sample Unit
Sample Tray40 sample positions70 sample positions120 sample positions
Sample TubeMicro cup & test tube & blood collection tube can be used. (Φ12 -13)mmx(25-100 )mm
Sample Volume2-30µL step by 0.1µL
Sample ProbeLiquid surface detection, timely tracking for liquid volume. Collision avoidance
Sample BarcodeSample barcode reader (optional)
Reagent Unit
Reagent Tray80 reagent positions (40 for Rl & 40 for R2), Non-stop cooling system with peltier pad inside, 24 hours 2℃-14℃, open system, could accept any reagent70 reagent positions, Non-stop cooling system with peltier pad inside, 24 hours 2℃-14℃, open system, could accept any reagent90 reagent positions, Non-stop cooling system with peltier pad inside, 24 hours 2℃-14℃, open system, could accept any reagent
Reagent Volume20-300µL, step by 1µL
Reagent NeedleLiquid surface detection, timely tracking for liquid volume. Collision avoidance
Regent BarcodeRegent barcode reader (optional)
Reaction Unit
Reaction Tray50 reaction cuvettes, new amorphous optical plastics reaction cups, perfect transmittance.44 reaction cuvettes, new amorphous optical plastics reaction cups, perfect transmittance.90 reaction cuvettes, new amorphous optical plastics reaction cups, perfect transmittance
Reaction Volume150uL-330uL
Reaction Time10 minutes
TemperaturePeltier pad incubation system, reaction temperature (37℃ ±0.1℃)
Mixing System
MixerPaddle-type mixing, effective reducing of carry-over
Optical System
Light SourceHalogen lamp
Wavelength340nm; 405nm; 450nm; 505nm; 546nm; 578nm; 630nm;700nm(4 more options)
Absorbance Range0-4.0 Abs
Resolution0.0001 Abs
Operating System
Operation SystemWindows XP, Windows 7, Windows 8, Windows 10
Report Printing6 formats optional, support custom pattern
InterfaceTCP/IP network interface
Working Conditions
Power SupplyAC 220/110V ±10%, 50/60Hz, 650W
Water Consumption6L/hour(maximum)8L/hour(maximum)12L/hour (maximum)15L/hour (maximum)
LanguageAll languages
Sizes(WxDxH)(mm)750x550x490750x475x535780x565x1120870x690x740920x650x11201110x765x1150
Shipping Size (WxDxH)(mm)890x710x760890x740x1390890x710x7601050x800x13801240x910x1360
N.W./G.W. (kg)70/8068/8896/14570/85127/180165/220

Data processing : Automatic calibration, test combination, effective time management of reagents, serum index, whole process detection, linear expansion of enzyme, blank deduction,dirty cuvette memory, cross infection prevention, patient information memory and association input, automatic report audit, data fuzzy query, report statistics and printing, reference range grading, alarm information classification, user operation privilege classification management.

Fully Automatic Biochemistry Analyzer Features:

  1. Internal and external mirror polishing, internal and external probe cleaning.

  2. Standard mixing programme for excellent mixing results

  3. 80 reagent positions, 40 sample positions

  4. Uninterrupted cooling system with built-in Peltier pads, 24 hours 2°C-14°C

  5. The user-friendly software interface is simple and easy to operate

  6. Automatic sample dilution (decrease, increase, normal)

  7. Automatic reaction result checking and alarm, automatic calibration result checking and alarm logging

  8. Linear and non-linear calibration, up to 8-point multi-point calibration

  9. Quality control applies to westbound, LT charts, cumulative

  10. A dedicated sampling probe equipped with a sensitive liquid sensor for timely reagent and sample residue feedback.

  11. Teflon coating mixer. No water droplets (reduced residue)


Previous: 
Next: 
Get Quotation/Become Distributor

About Company​​​​​​​

As a professional lab and medical equipment manufacturer, Scitek Global is certified by ISO 9001, ISO 13485, ISO 45001 and ISO 14001. Almost all our products are certified by ETL, CE and FDA .

Scitek Global looks forward to establishing cooperation with more distributors all over the world, and working together to create greater customer value.

Quick Links

Contact Us
Scitek Global Co.,Ltd
  No. 7000 Jingshi Road, Jinan City, Shandong Province, China
/  +86-531-82893797
  Inquiry: info@scitekglobal.com
Service: 
service@scitekglobal.com
Complaints: 

complaints@scitekglobal.com
 
Scitek Global Inc.
9999 Bellaire Blvd Ste 505, Houston, TX 77036, United States
  +1 (915) 4126735
info@scitekglobal.net
 
Scitek Ethiopia
 tsion@scitekglobal.com
Copyright © 2023 Scitek Global Co., Ltd. All rights reserved.  Sitemap  Privacy Policy