| Availability: | |
|---|---|
| Quantity: | |
This auto biochemistry analyzer from Scitek is designed to analyze a variety of test samples. This includes blood, plasma, serum, urine and more. It supports the simultaneous execution of multiple tests and offers a wider range of tests. Greatly simplifies your workflow.
| Model | BA-260 |
|---|---|
| Throughput/Efficiency speed | 260 tests/hour |
| Analysis Method | End-point, kinetic, two-point, double-reagents, double-wavelength, multi-standard etc, open to various reagents |
| Reaction System | Reaction Cuvette: 90 pcs made of special material |
| Optical Length of Cuvette: 6mm | |
| Reaction Volume: 200~500µl | |
| Reaction Time: 0--10 minutes | |
| Reaction Temperature: 37℃±0.1℃ | |
| Mixing System: Independent mixing probe | |
| Sample/Reagents Handling | Sample Position: 40 pcs (Include standard,QC,STAT positions) |
| Sample volume: 2-50µl, 0.1µl step | |
| Sample Probe Cleaning: Automatic internal & external washing | |
| Reagent Position: 40 pcs (With refrigerated function, 2℃-8℃) | |
| Reagent Volume:10-500µl, 1µl step | |
| Optical System | Light Source: halogen-tungsten lamp |
| Wavelength: 340-690nm, 9 wavelengths, precision ±1.5nm | |
| Absorbance Range: 0-5.0Abs | |
| Resolution: 0.0001Abs | |
| Spectrophotometry: Rear spectrophotometry | |
| Cleaning System | 8-step automatic washing, automatic cuvette dry function |
| Water Consumption: 4L/hour | |
| Power Supply | 100-240V, 50/60Hz, 1KVA |
| Temperature | 10℃-35℃ |
| Humidity | ≤90% |
| Operation System | Windows Operating System |
| Input | RS-232 interface / keyboard / computer |
| Output | Multi-format printout |
| Upper Cabinet Size (W×D×H)(mm) | 700×650×530 |
| Bottom Cabinet Size (W×D×H)(mm) | 700×705×620 |
| Upper Cabinet Packing Size (W×D×H)(mm) | 830×880×732 |
| Bottom Cabinet Packing Size (W×D×H)(mm) | 800×880×855 |
| Upper Cabinet N.W./G.W. (kg) | 62/95 |
| Bottom Cabinet N.W./G.W. (kg) | 47/74 |
| Sample/Reagent Position | ![]() |
| |
| Reaction Cuvettes | ![]() |
| |
| 8-step auto cleaning System | ![]() |
| |
| ![]() |
| ![]() |
| ![]() |
| ![]() |
| ![]() |
Fully automatically, discrete, random STAT function
Online test items: At most 40 testing items
Data Processing: Memory up to 200,000 patients’ data
Sample Dilution: Automatic/Manual pre-dilution, with dilution ratio up to 1:100
Reagent Probe: Automatic liquid level detect, with collision protection function
Reagent Probe Cleaning: Automatic internal & external washing
The biochemistry analyzer is packed in a plywood wooden case.
QC: Various QC managements, insert QC randomly; save, display & print QC chart; define different QC in advance
Calibration: Linear/nonlinear multi-points calibration
Re-test: Retest the sample automatically when the result is out of the linearity range or the sample is not sufficient
This auto biochemistry analyzer from Scitek is designed to analyze a variety of test samples. This includes blood, plasma, serum, urine and more. It supports the simultaneous execution of multiple tests and offers a wider range of tests. Greatly simplifies your workflow.
| Model | BA-260 |
|---|---|
| Throughput/Efficiency speed | 260 tests/hour |
| Analysis Method | End-point, kinetic, two-point, double-reagents, double-wavelength, multi-standard etc, open to various reagents |
| Reaction System | Reaction Cuvette: 90 pcs made of special material |
| Optical Length of Cuvette: 6mm | |
| Reaction Volume: 200~500µl | |
| Reaction Time: 0--10 minutes | |
| Reaction Temperature: 37℃±0.1℃ | |
| Mixing System: Independent mixing probe | |
| Sample/Reagents Handling | Sample Position: 40 pcs (Include standard,QC,STAT positions) |
| Sample volume: 2-50µl, 0.1µl step | |
| Sample Probe Cleaning: Automatic internal & external washing | |
| Reagent Position: 40 pcs (With refrigerated function, 2℃-8℃) | |
| Reagent Volume:10-500µl, 1µl step | |
| Optical System | Light Source: halogen-tungsten lamp |
| Wavelength: 340-690nm, 9 wavelengths, precision ±1.5nm | |
| Absorbance Range: 0-5.0Abs | |
| Resolution: 0.0001Abs | |
| Spectrophotometry: Rear spectrophotometry | |
| Cleaning System | 8-step automatic washing, automatic cuvette dry function |
| Water Consumption: 4L/hour | |
| Power Supply | 100-240V, 50/60Hz, 1KVA |
| Temperature | 10℃-35℃ |
| Humidity | ≤90% |
| Operation System | Windows Operating System |
| Input | RS-232 interface / keyboard / computer |
| Output | Multi-format printout |
| Upper Cabinet Size (W×D×H)(mm) | 700×650×530 |
| Bottom Cabinet Size (W×D×H)(mm) | 700×705×620 |
| Upper Cabinet Packing Size (W×D×H)(mm) | 830×880×732 |
| Bottom Cabinet Packing Size (W×D×H)(mm) | 800×880×855 |
| Upper Cabinet N.W./G.W. (kg) | 62/95 |
| Bottom Cabinet N.W./G.W. (kg) | 47/74 |
| Sample/Reagent Position | ![]() |
| |
| Reaction Cuvettes | ![]() |
| |
| 8-step auto cleaning System | ![]() |
| |
| ![]() |
| ![]() |
| ![]() |
| ![]() |
| ![]() |
Fully automatically, discrete, random STAT function
Online test items: At most 40 testing items
Data Processing: Memory up to 200,000 patients’ data
Sample Dilution: Automatic/Manual pre-dilution, with dilution ratio up to 1:100
Reagent Probe: Automatic liquid level detect, with collision protection function
Reagent Probe Cleaning: Automatic internal & external washing
The biochemistry analyzer is packed in a plywood wooden case.
QC: Various QC managements, insert QC randomly; save, display & print QC chart; define different QC in advance
Calibration: Linear/nonlinear multi-points calibration
Re-test: Retest the sample automatically when the result is out of the linearity range or the sample is not sufficient