Model | MWQ-B300I | |
---|---|---|
Parameters | pH/EC/ISE/Temp. (mV/ORP/pX/Resistivity/TDS/Sal.) | |
pH | Range | -2.00 to 20.00pH |
Resolution | 0.1, 0.01 pH | |
Accuracy | ±0.01 pH | |
Calibration Points | Up to 5 | |
Standard Customization | Yes | |
Standard Recognition | NIST, GB and DIN buffers | |
Slope Limit | Yes | |
mV | Range | -2000.0 to 2000.0 mV |
Resolution | 0.1 mV | |
Accuracy | ±0.3 mV or ±0.1% | |
pX | Range | -2.00 to 20.00 |
Resolution | 0.1, 0.01 pX | |
Accuracy | ±0.01 pX | |
Calibration Points | Up to 5 | |
ISE | Range | 1E-9 to 9.999E9 |
Unit | mol/L, mmol/L, g/L, mg/L, μg/L, ppm | |
Resolution | Up to 4 significant digits | |
Accuracy | ±0.5% | |
Calibration Points | Up to 5 | |
Conductivity | Range | 0.000 μS/cm to 1000 mS/cm |
Resolution | 0.001 μS/cm minimum, | |
various with range selection | ||
Accuracy | ±1.0% FS | |
Reference Temperature | 20, 25 ℃ | |
Calibration Points | Up to 3 | |
Standard Recognition | 84μS/cm, 1413μS/cm, 12.88mS/cm | |
Resistivity | Range | 5.00 Ω·cm~20.00 MΩ·cm |
Resolution | 0.01 Ω·cm minimum | |
Accuracy | ±1.0% FS | |
TDS | Range | 0.00mg/L~300g/L |
Resolution | 0.01mg/L minimum, various with range selection | |
Accuracy | ±1.0% FS | |
Salinity | Range | (0.00~8.00)% |
Resolution | 0.0001 | |
Accuracy | ±0.2% | |
Temperature | Range | -5 to 110 ℃, 23 to 230ºF |
Unit | ℃,ºF | |
Resolution | 0.1 | |
Accuracy | ±0.2 | |
Measurement | Reading Mode | Auto Read (Fast, Medium, Slow), Timed, Continuous |
Reading Prompts | Reading, Stable, Locked | |
Temp. Compensation | ATC, MTC | |
Data Management | Data Storage | 500 results each |
GLP Features | Yes | |
Inputs | pH Electrode | BNC(Q9) |
DO with Temp. Probe | 4-pin aviation connector | |
Conductivity with Temp. Probe | 5-pin aviation connector | |
Outputs | USB | USB 2.0 flash memory device, PC |
RS 232 | printer | |
Display Options | Backlight | Yes |
Auto Shutdown | 1~60 min, off | |
IP Rating | IP54 | |
Date and Time | Yes | |
General | Electricity | AC Adapter, 100-240V AC input, DC9V output |
Sizes(W×D×H) | 242x195x68 | |
Shipping Size (W×D×H)(mm) | 370×305×330 | |
N.W./G.W. (kg) | 0.9/6.5 |
Scitek's MWQ-B300I is a multiparameter water quality meter. It adopts high precision algorithm chip and electrode to ensure fast and accurate response. Ideal for drinking water, hydroponics, aquariums, aquaculture, laboratories, and food processing industries
The multiparameter water quality meter has a backlit LCD screen, so you don't have to worry about being unable to read the display at night or in low light.
Automatic Temperature Compensation (ATC) ensures accurate results at any temperature.
5.7 inch LCD
Multiple readings
The lightweight and convenient design allows you to take measurements anytime, anywhere
Support for USB or RS-232 communication.
Can save 500 groups of data for easy access and retrieval.
IP54 waterproof
Model | MWQ-B300I | |
---|---|---|
Parameters | pH/EC/ISE/Temp. (mV/ORP/pX/Resistivity/TDS/Sal.) | |
pH | Range | -2.00 to 20.00pH |
Resolution | 0.1, 0.01 pH | |
Accuracy | ±0.01 pH | |
Calibration Points | Up to 5 | |
Standard Customization | Yes | |
Standard Recognition | NIST, GB and DIN buffers | |
Slope Limit | Yes | |
mV | Range | -2000.0 to 2000.0 mV |
Resolution | 0.1 mV | |
Accuracy | ±0.3 mV or ±0.1% | |
pX | Range | -2.00 to 20.00 |
Resolution | 0.1, 0.01 pX | |
Accuracy | ±0.01 pX | |
Calibration Points | Up to 5 | |
ISE | Range | 1E-9 to 9.999E9 |
Unit | mol/L, mmol/L, g/L, mg/L, μg/L, ppm | |
Resolution | Up to 4 significant digits | |
Accuracy | ±0.5% | |
Calibration Points | Up to 5 | |
Conductivity | Range | 0.000 μS/cm to 1000 mS/cm |
Resolution | 0.001 μS/cm minimum, | |
various with range selection | ||
Accuracy | ±1.0% FS | |
Reference Temperature | 20, 25 ℃ | |
Calibration Points | Up to 3 | |
Standard Recognition | 84μS/cm, 1413μS/cm, 12.88mS/cm | |
Resistivity | Range | 5.00 Ω·cm~20.00 MΩ·cm |
Resolution | 0.01 Ω·cm minimum | |
Accuracy | ±1.0% FS | |
TDS | Range | 0.00mg/L~300g/L |
Resolution | 0.01mg/L minimum, various with range selection | |
Accuracy | ±1.0% FS | |
Salinity | Range | (0.00~8.00)% |
Resolution | 0.0001 | |
Accuracy | ±0.2% | |
Temperature | Range | -5 to 110 ℃, 23 to 230ºF |
Unit | ℃,ºF | |
Resolution | 0.1 | |
Accuracy | ±0.2 | |
Measurement | Reading Mode | Auto Read (Fast, Medium, Slow), Timed, Continuous |
Reading Prompts | Reading, Stable, Locked | |
Temp. Compensation | ATC, MTC | |
Data Management | Data Storage | 500 results each |
GLP Features | Yes | |
Inputs | pH Electrode | BNC(Q9) |
DO with Temp. Probe | 4-pin aviation connector | |
Conductivity with Temp. Probe | 5-pin aviation connector | |
Outputs | USB | USB 2.0 flash memory device, PC |
RS 232 | printer | |
Display Options | Backlight | Yes |
Auto Shutdown | 1~60 min, off | |
IP Rating | IP54 | |
Date and Time | Yes | |
General | Electricity | AC Adapter, 100-240V AC input, DC9V output |
Sizes(W×D×H) | 242x195x68 | |
Shipping Size (W×D×H)(mm) | 370×305×330 | |
N.W./G.W. (kg) | 0.9/6.5 |
Scitek's MWQ-B300I is a multiparameter water quality meter. It adopts high precision algorithm chip and electrode to ensure fast and accurate response. Ideal for drinking water, hydroponics, aquariums, aquaculture, laboratories, and food processing industries
The multiparameter water quality meter has a backlit LCD screen, so you don't have to worry about being unable to read the display at night or in low light.
Automatic Temperature Compensation (ATC) ensures accurate results at any temperature.
5.7 inch LCD
Multiple readings
The lightweight and convenient design allows you to take measurements anytime, anywhere
Support for USB or RS-232 communication.
Can save 500 groups of data for easy access and retrieval.
IP54 waterproof