| Availability: | |
|---|---|
| Quantity: | |
Application:
The PCR-TC96M thermal cycler was engineered for researchers who require absolute accuracy,
reproducibility, and efficiency in their molecular biology workflows.
Advantage:
1. 10-inch LCD touch screen, easy to use and fast response. Real-time display of program running status,
can be used independently without a computer.
2. Rapid temperature rise and fall, effectively shortening the experiment time.
3. Customize experimental temperature according to needs, with temperature control and maintenance functions.
4. Powerful program editing function to meet different reagent requirements.
5. Before the test is run, the hot cover is closed to confirm the prompt function.
Specification:
| Model | PCR-TC96M |
| Capacity | 96×0.2 mL; 8×0.2 mL; PCR strip tubes |
| Sample Volume | 10-200 uL |
| Temperature Range | 4 ℃~105 ℃ |
| Thermal Cycle Mode | Peltier |
| Max. Heating Rate | 4.0 ℃/s |
| Uniformity | ﹤0.3 ℃ |
| Temperature Accuracy | ±0.3 ℃ |
| Display Resolution | ±0.1 ℃ |
| Temperature Control | Block\Tube |
| Gradient Temp. Range | 30~99 ℃ |
| Gradient Spread | 1~42 ℃ |
| Hot Lid Temperature | 30℃~110 ℃ |
| Number of Programs | >100 |
| Max. No. of Step | 30 |
| Max. No. of Cycle | 99 |
| Power Supply | AC 220/110 V, 50/60 Hz |
| Consumption | 500 W |
| External Size (W×D×H) | 280×398×257 mm |
| Shipping Size (W×D×H) | 380×495×380 mm |
| N.W/G.W. | 8 kg/12 kg |
Application:
The PCR-TC96M thermal cycler was engineered for researchers who require absolute accuracy,
reproducibility, and efficiency in their molecular biology workflows.
Advantage:
1. 10-inch LCD touch screen, easy to use and fast response. Real-time display of program running status,
can be used independently without a computer.
2. Rapid temperature rise and fall, effectively shortening the experiment time.
3. Customize experimental temperature according to needs, with temperature control and maintenance functions.
4. Powerful program editing function to meet different reagent requirements.
5. Before the test is run, the hot cover is closed to confirm the prompt function.
Specification:
| Model | PCR-TC96M |
| Capacity | 96×0.2 mL; 8×0.2 mL; PCR strip tubes |
| Sample Volume | 10-200 uL |
| Temperature Range | 4 ℃~105 ℃ |
| Thermal Cycle Mode | Peltier |
| Max. Heating Rate | 4.0 ℃/s |
| Uniformity | ﹤0.3 ℃ |
| Temperature Accuracy | ±0.3 ℃ |
| Display Resolution | ±0.1 ℃ |
| Temperature Control | Block\Tube |
| Gradient Temp. Range | 30~99 ℃ |
| Gradient Spread | 1~42 ℃ |
| Hot Lid Temperature | 30℃~110 ℃ |
| Number of Programs | >100 |
| Max. No. of Step | 30 |
| Max. No. of Cycle | 99 |
| Power Supply | AC 220/110 V, 50/60 Hz |
| Consumption | 500 W |
| External Size (W×D×H) | 280×398×257 mm |
| Shipping Size (W×D×H) | 380×495×380 mm |
| N.W/G.W. | 8 kg/12 kg |