| Availability: | |
|---|---|
| Quantity: | |
1. Corrosion Resistance: Aluminum alloy centrifuge chamber with Teflon coating.
2. Easy operation: One button start/stop function enables automatic operation.
3. Sample safety: Automatic vacuum release after power off to protect sample safety.
4. Completely Accessories: Over 12 rotors are available as optional configurations.
5. Speed adjustable: The speed is adjustable from 300 rpm to 1800 rpm, which helps prevent sample boiling.
6. User-friendly design: The device has a height of 24 cm, making it convenient for sample retrieval and placement.
7. Temperature quick settings: Room temperature, 30 ℃, 45 ℃ and 60 ℃, ensuring efficient and safe for sample concentration.
8. Vacuum Delayed Start: The vacuum delayed start function initiates vacuum extraction after the preset speed is reached.
9. Automatic alarm for inadequate vacuum value, ensuring sample safety.
10. Specially designed intake filtration components to keep samples away from cross contamination.
Model | VCC-V200 |
Speed Range | 300–1800 rpm |
Maximum Centrifugal Force | 430 ×g |
Time Range | 0–9999 mins |
Temperature Control Range | RT + 5 ℃ to 80 ℃ |
Ultimate Vacuum Value | ≤ 30 Pa (≤ 0.3 mbar) |
Noise | ≤ 60 dB (A) |
Standard Rotor | 90×1.5/2 mL |
Power | 1100 W |
Power Supply | AC 220/110 V, 50/60 Hz, 10 A |
Overall Size (W×D×H) | 520×360×240 mm |
Shipping Size (W×D×H) | 630×450×550 mm |
N.W/G.W | 25.8/31 kg |
| Optional | Rotor |
| Recommended Equipment (excluding) | Cold Trap (CT-M50/CT-M80), Diaphragm Vacuum Pump (DVP-M480) |
Type | Aperture (Number and Capacity of Sample Tube) |
Standard | 90×1.5/2 mL |
Optional | 24×5 mL+66×1.5 mL |
54×1.5 mL+48×0.6 mL | |
24×8×0.2 mL | |
40×10 mL | |
20×10 mL(Round bottom) | |
8×50 mL+8×10 mL | |
8×50 mL(Conical bottom) | |
20×15 mL(Conical bottom) | |
64×2 mL(Glass vial) | |
8×40 mL+8×10 mL | |
16×20 mL (Glass vial) | |
2×96 Microplate |


| Model | CT-M50 | CT-M80 |
| Temperature | -50 ℃ | -80 ℃ |
| Cold Trap Capacity | 2000 mL | 4500 mL |
| Coil Way | External coil | Internal coil |
| Cover Material | Polypropylene | |
| Power | 900 W | 1800 W |
| Power Supply | AC 110/220 V, 50/60 Hz, 10 A | |
| Size (D×W×H) | 500×210×470 mm | 600×360×630 mm |
| Shipping size (D×W×H) | 590×300×560 mm | 670×430×710 mm |
| N.W./G.W. | 32/39.5 kg | 70/82 kg |

| Model | DVP-M480 |
| Pumping Speed (L/min) | 35 L/min |
| Ultimate Vacuum (MPa) | ≤ 8 mbar |
| Noise | ≤ 50 dB |
| Power (W) | 200 W |
| Power Supply | AC 110/220 V, 50/60 Hz, 10 A |
| Size (D×W×H) | 266×163×257 mm |
| Shipping size (D×W×H) | 370×330×370 mm |
| N.W./G.W. | 9.2/13 kg |
1. Corrosion Resistance: Aluminum alloy centrifuge chamber with Teflon coating.
2. Easy operation: One button start/stop function enables automatic operation.
3. Sample safety: Automatic vacuum release after power off to protect sample safety.
4. Completely Accessories: Over 12 rotors are available as optional configurations.
5. Speed adjustable: The speed is adjustable from 300 rpm to 1800 rpm, which helps prevent sample boiling.
6. User-friendly design: The device has a height of 24 cm, making it convenient for sample retrieval and placement.
7. Temperature quick settings: Room temperature, 30 ℃, 45 ℃ and 60 ℃, ensuring efficient and safe for sample concentration.
8. Vacuum Delayed Start: The vacuum delayed start function initiates vacuum extraction after the preset speed is reached.
9. Automatic alarm for inadequate vacuum value, ensuring sample safety.
10. Specially designed intake filtration components to keep samples away from cross contamination.
Model | VCC-V200 |
Speed Range | 300–1800 rpm |
Maximum Centrifugal Force | 430 ×g |
Time Range | 0–9999 mins |
Temperature Control Range | RT + 5 ℃ to 80 ℃ |
Ultimate Vacuum Value | ≤ 30 Pa (≤ 0.3 mbar) |
Noise | ≤ 60 dB (A) |
Standard Rotor | 90×1.5/2 mL |
Power | 1100 W |
Power Supply | AC 220/110 V, 50/60 Hz, 10 A |
Overall Size (W×D×H) | 520×360×240 mm |
Shipping Size (W×D×H) | 630×450×550 mm |
N.W/G.W | 25.8/31 kg |
| Optional | Rotor |
| Recommended Equipment (excluding) | Cold Trap (CT-M50/CT-M80), Diaphragm Vacuum Pump (DVP-M480) |
Type | Aperture (Number and Capacity of Sample Tube) |
Standard | 90×1.5/2 mL |
Optional | 24×5 mL+66×1.5 mL |
54×1.5 mL+48×0.6 mL | |
24×8×0.2 mL | |
40×10 mL | |
20×10 mL(Round bottom) | |
8×50 mL+8×10 mL | |
8×50 mL(Conical bottom) | |
20×15 mL(Conical bottom) | |
64×2 mL(Glass vial) | |
8×40 mL+8×10 mL | |
16×20 mL (Glass vial) | |
2×96 Microplate |


| Model | CT-M50 | CT-M80 |
| Temperature | -50 ℃ | -80 ℃ |
| Cold Trap Capacity | 2000 mL | 4500 mL |
| Coil Way | External coil | Internal coil |
| Cover Material | Polypropylene | |
| Power | 900 W | 1800 W |
| Power Supply | AC 110/220 V, 50/60 Hz, 10 A | |
| Size (D×W×H) | 500×210×470 mm | 600×360×630 mm |
| Shipping size (D×W×H) | 590×300×560 mm | 670×430×710 mm |
| N.W./G.W. | 32/39.5 kg | 70/82 kg |

| Model | DVP-M480 |
| Pumping Speed (L/min) | 35 L/min |
| Ultimate Vacuum (MPa) | ≤ 8 mbar |
| Noise | ≤ 50 dB |
| Power (W) | 200 W |
| Power Supply | AC 110/220 V, 50/60 Hz, 10 A |
| Size (D×W×H) | 266×163×257 mm |
| Shipping size (D×W×H) | 370×330×370 mm |