Availability: | |
---|---|
Quantity: | |
The syringe pump is suitable for biological laboratory, electrophysiology, chemistry, pharmaceutical and many other general fields.
The SP-11Y micro syringe pump is ideal for biological labs, offering single-channel perfusion/extraction. It accommodates various syringe and injector sizes, perfect for precise, low-flow liquid delivery.
Syringe selection is effortless with the option to choose from a list or input the syringe inner diameter directly.
User-friendly interface features a large LCD display and intuitive digital knobs and membrane buttons for easy operation.
Benefit from power-down memory function: Settings are saved in EEPROM, eliminating the need for reconfiguration after power restoration.
Includes traffic jam protection: Halts operation and alerts with a whistle alarm if the pump encounters blockages.
Connects via RS485 communication for seamless integration with host computers and control via background software.
External control interface supports input/output control functions.
Achieve precise flow rates with liquid volume calibration function.
Prevent syringe damage with the syringe protection function, adjustable via a limit block
Mode | SP-11Y |
---|---|
Working Mode | Working mode (perfusion) |
Execution Unit Quantity | 1 |
Stroke Resolution | 0.156 um |
Linear Velocity Range | 5μm/min-130 mm/min (Flow rate = linear velocity x internal cross-sectional area of syringe) |
Stroke Control Accuracy | The error≤0.5% (Trip≥30% of the maximum trip) |
Flow Correction | More accurate fluid levels are obtained through calibration procedures |
Syringe Selection | Built-in main manufacturer, model syringe for choice |
Applicable Power Supply | Broad voltage AC 90-265V.50 Hz/60 Hz |
Working Environment | Temperature 0~40°C, relative humidity <80% |
Drive Weight | 3.9 Kg |
Communication Interface | RS 485 (MODBUS Protocol) |
Power Consumption | <15W |
Control Type Input | 2 start and stop control inputs, 1 falling edge trigger signal control start and stop; 1 tTL level signal control start and stop |
Maximum Stroke | 140 mm |
Status Output | 2OCgate signal output, used to indicate the start, stop and direction status |
Rated Linear Thrust | >290N |
Display Parameter Setting | Fluid volume, flow rate, or linear velocity |
Linear Speed Adjustment Resolution | 5μm/min |
Operation Parameter Setting | Dispense fluid volume, syringe time, etc |
External Size(LxWxH)(mm) | 280x210x140 |
Syringe Customization | Can be directly input into the syringe |
Applicable syringe (or injector) specifications | Applicable syringe diameter (mm) | Reference flow range (ul/ min-ML /min) |
---|---|---|
10μl | 0.50 | 0.001-0.0128 |
25μl | 0.80 | 0.0025-0.0327 |
50μl | 1.10 | 0.0048-0.0618 |
100μl | 1.60 | 0.0101-0.1307 |
250μl | 2.30 | 0.0208-0.2701 |
500μl | 3.25 | 0.0415-0.5392 |
1ml | 4.72 | 0.0875-1.1373 |
2ml | 9.00 | 0.3181-4.1351 |
5ml | 13.10 | 0.6739-8.7608 |
10ml | 16.60 | 1.0821-14.068 |
20ml | 19.00 | 1.4176-18.429 |
30ml | 23.00 | 2.0774-27.006 |
60ml | 29.14 | 3.3346-43.349 |
The syringe pump is suitable for biological laboratory, electrophysiology, chemistry, pharmaceutical and many other general fields.
The SP-11Y micro syringe pump is ideal for biological labs, offering single-channel perfusion/extraction. It accommodates various syringe and injector sizes, perfect for precise, low-flow liquid delivery.
Syringe selection is effortless with the option to choose from a list or input the syringe inner diameter directly.
User-friendly interface features a large LCD display and intuitive digital knobs and membrane buttons for easy operation.
Benefit from power-down memory function: Settings are saved in EEPROM, eliminating the need for reconfiguration after power restoration.
Includes traffic jam protection: Halts operation and alerts with a whistle alarm if the pump encounters blockages.
Connects via RS485 communication for seamless integration with host computers and control via background software.
External control interface supports input/output control functions.
Achieve precise flow rates with liquid volume calibration function.
Prevent syringe damage with the syringe protection function, adjustable via a limit block
Mode | SP-11Y |
---|---|
Working Mode | Working mode (perfusion) |
Execution Unit Quantity | 1 |
Stroke Resolution | 0.156 um |
Linear Velocity Range | 5μm/min-130 mm/min (Flow rate = linear velocity x internal cross-sectional area of syringe) |
Stroke Control Accuracy | The error≤0.5% (Trip≥30% of the maximum trip) |
Flow Correction | More accurate fluid levels are obtained through calibration procedures |
Syringe Selection | Built-in main manufacturer, model syringe for choice |
Applicable Power Supply | Broad voltage AC 90-265V.50 Hz/60 Hz |
Working Environment | Temperature 0~40°C, relative humidity <80% |
Drive Weight | 3.9 Kg |
Communication Interface | RS 485 (MODBUS Protocol) |
Power Consumption | <15W |
Control Type Input | 2 start and stop control inputs, 1 falling edge trigger signal control start and stop; 1 tTL level signal control start and stop |
Maximum Stroke | 140 mm |
Status Output | 2OCgate signal output, used to indicate the start, stop and direction status |
Rated Linear Thrust | >290N |
Display Parameter Setting | Fluid volume, flow rate, or linear velocity |
Linear Speed Adjustment Resolution | 5μm/min |
Operation Parameter Setting | Dispense fluid volume, syringe time, etc |
External Size(LxWxH)(mm) | 280x210x140 |
Syringe Customization | Can be directly input into the syringe |
Applicable syringe (or injector) specifications | Applicable syringe diameter (mm) | Reference flow range (ul/ min-ML /min) |
---|---|---|
10μl | 0.50 | 0.001-0.0128 |
25μl | 0.80 | 0.0025-0.0327 |
50μl | 1.10 | 0.0048-0.0618 |
100μl | 1.60 | 0.0101-0.1307 |
250μl | 2.30 | 0.0208-0.2701 |
500μl | 3.25 | 0.0415-0.5392 |
1ml | 4.72 | 0.0875-1.1373 |
2ml | 9.00 | 0.3181-4.1351 |
5ml | 13.10 | 0.6739-8.7608 |
10ml | 16.60 | 1.0821-14.068 |
20ml | 19.00 | 1.4176-18.429 |
30ml | 23.00 | 2.0774-27.006 |
60ml | 29.14 | 3.3346-43.349 |