Model: IPC-8AS

Test Range: 1-700 μm
Minimum Injection Volume: ≥ 0.1 mL
Counting Range: 0-9,999,999 particles
Detectable Particle Concentration: 0-20,000 particles/mL
Stirring Speed: 0-2000 rpm
It enables reliable measurement of insoluble particles in intravenous injections, pharmaceutical packaging materials, anesthesia equipment, biological products, eye drops, etc.
Availability:
Quantity:

The IPC-8AS insoluble particle counter enables direct detection of the content and size of insoluble particles in injections, sterile powders, infusion sets, and pharmaceutical packaging materials. It adopts a high-performance imported laser light source and compensation circuit to ensure testing accuracy for both colorless and colored samples, supporting direct analysis of electrolyte-free articles. Sampling slits and pipelines are made of imported 316L stainless steel and PTFE materials, allowing direct detection of organic solvents, oil-based matrices, and other special solutions.

Insoluble Particle Counter Feature:

1. Features unlimited automatic channel calibration: automatically calibrates channel data and resolution without the need for on-site disassembly and calibration by manufacturer engineers, enabling users to obtain accurate data anytime.

2. 8-channel selection (full / partial channel setup) with user-defined volume sampling supports independent channel configuration, calibration, and testing.
3. A dedicated testing program for small-volume injections (ampoules). Injection volume can be set according to ampoule specifications, and the system automatically converts test results into particle size and count per container, complying with international universal requirements. Standard configuration includes a 10 mL precision high-pressure syringe pump for sampling power, meeting diverse experimental needs.  

4. An imported high-pressure syringe pump sampling system, injection volume can be set according to sample types, featuring high injection precision to meet the testing requirements of high-viscosity samples.
5. Capable of detecting insoluble particles in intravenous injections, pharmaceutical packaging materials, anesthesia equipment, biological products, eye drops, etc.
6. Utilizes a propeller-type glass stirrer with adjustable constant speed: stir speed is real-time monitorable, ensuring uniform particle dispersion in the container and improving data accuracy.

7. Unaffected by geographical factors, it is suitable for use in regions with different altitudes.
8. Built-in injection drug names from the Chinese Pharmacopoeia (ChP) for on-demand retrieval and printing. Users can customize and save test protocols for direct recall in subsequent use.

9. Computers are included as standard equipment, with an optional tablet available. The tablet can be mounted on the upper section of it to optimize space utilization.
10. Data storage and query functions to facilitate paperless office. Professional software ensures data protection with no risk of data loss.
11. Automatic test data processing with multiple printing modes for all sample types, meeting the requirements of different sample test reports.
12. Full computer software control, fully complying with GMP computerized management requirements. Features five-level permission management, with user access period setting and password expiration reminder functions.
13. Supports work log retrieval and export, enabling automatic scheduled backup or manual backup. Equipped with a computerized audit trail system workstation: realizes unlimited storage of experimental data and behavioral data with automatic scheduled backup, effectively ensuring data validity.

Insoluble Particle Counter Specification:

Model

IPC-8AS

Optical System

Laser light obscuration method

Test Range

1-700 μm

Detection Channel

8 channels

Channel Setting

≥ 2 µm, ≥ 5 µm, ≥ 8 µm, ≥ 10 µm, ≥ 12 µm, ≥ 20 µm, ≥ 25 µm, ≥ 50 µm

Pharmacopoeial Standard Dedicated Channel

≥ 10 μm, ≥ 25 μm

Minimum Injection Volume

0.1 mL

Injection Volume

Any volume ≥ 0.1 mL

Counting Range

0-9,999,999 particles

Detectable Particle Concentration

0-20,000 particles/mL

Relative Standard Deviation (RSD)

≤ 1.5% (for standard particles ≥ 1000 particles/mL)

Sampling Time

< 5 seconds (5 mL), < 3 minutes (100 mL)

Accuracy

Within ±4% of the specified value

Channel Resolution

≥ 95% (for ≥ 10 μm channel)

Stirring Speed

0-2000 rpm

Operating Temperature

0-40 ℃

Power Supply

AC 220 V ± 10%, 50 Hz

Power

≤ 90 W

External Size (W×D×H)

352×329×423 mm

Shipping Size (W×D×H)

450×450×620 mm

Previous: 
Next: 
Get Quotation/Become Distributor

About Company​​​​​​​

As a professional lab and medical equipment manufacturer, Scitek Global is certified by ISO 9001, ISO 13485, ISO 45001 and ISO 14001. Almost all our products are certified by ETL, CE and FDA .

Scitek Global looks forward to establishing cooperation with more distributors all over the world, and working together to create greater customer value.

Quick Links

Contact Us
Scitek Global Co.,Ltd
  No. 7000 Jingshi Road, Jinan City, Shandong Province, China
/  +86-531-82893797
  Inquiry: info@scitekglobal.com
 

9999 Bellaire Blvd Ste 505, Houston, TX 77036, United States
  +1 (915) 4126735
info@scitekglobal.net
 
Copyright © 2023 Scitek Global Co., Ltd. All rights reserved.  Sitemap  Privacy Policy