Availability: | |
---|---|
Quantity: | |
Model | DB-H1000 | |
---|---|---|
Block | ES series | ESC series |
Temp Setting Range | 0℃~100℃ | -10℃~100℃ |
Temp Control Range | RT.+5℃~100℃ | Below RT.of 25 ℃~100℃ |
Time Range | 1sec~99min59sec | |
Temp. Accuracy | ≤±0.3℃ (At 37℃) | |
Display Accuracy | 0.1℃ | |
Temp. Uniformity | ≤±0.3℃ (At 37℃) | |
Heating Time | ≤12min (From 25℃ to 100℃) | |
Cooling Time 1 | \ | ≤12min (From 100℃ to 25℃) |
Cooling Time 2 | \ | ≤25min (From RT. to Below RT.of 25 ℃) |
Heating Lid Temp. Setting Range | OFF~+10℃ | |
Heating Lid Temp. Accuracy | ≤±0.5℃ | |
Heating Lid Heating Time | ≤10min (From 25℃ to 100℃) | |
Storage at 4℃ | \ | Yes |
Multi-points Running | Yes (Max 5 points) | |
Multi-cycle | Yes (Max 99 times) | |
Auto Running | Yes | |
Auto Heating | Yes | |
Auto Resume to Run | Yes | |
Capacity | See optional block | |
Consumption | 150W | |
Power Supply | AC220/110V, 50/60Hz | |
Size (W×D×H)(mm)(Without the Heating Block) | 200x300x210 | |
Shipping Size (W×D×H)(mm) | 400x320x330 | |
N.W./G.W. (kg) | 4/6 |
Precise and efficient temperature control ensures reliable and consistent results in experiments where temperature accuracy is critical.
Rapid cooling characteristics are essential for maintaining sample integrity and saving valuable time in the laboratory workflow.
Adjustable time ranges give users greater flexibility to meet the time requirements of different experiments.
Features a heated lid setting to provide a controlled sample environment, suitable for a wider range of experimental needs.
Temperature uniformity of ≤±0.3°C helps to improve the repeatability and accuracy of experiments.
Model | DB-H1000 | |
---|---|---|
Block | ES series | ESC series |
Temp Setting Range | 0℃~100℃ | -10℃~100℃ |
Temp Control Range | RT.+5℃~100℃ | Below RT.of 25 ℃~100℃ |
Time Range | 1sec~99min59sec | |
Temp. Accuracy | ≤±0.3℃ (At 37℃) | |
Display Accuracy | 0.1℃ | |
Temp. Uniformity | ≤±0.3℃ (At 37℃) | |
Heating Time | ≤12min (From 25℃ to 100℃) | |
Cooling Time 1 | \ | ≤12min (From 100℃ to 25℃) |
Cooling Time 2 | \ | ≤25min (From RT. to Below RT.of 25 ℃) |
Heating Lid Temp. Setting Range | OFF~+10℃ | |
Heating Lid Temp. Accuracy | ≤±0.5℃ | |
Heating Lid Heating Time | ≤10min (From 25℃ to 100℃) | |
Storage at 4℃ | \ | Yes |
Multi-points Running | Yes (Max 5 points) | |
Multi-cycle | Yes (Max 99 times) | |
Auto Running | Yes | |
Auto Heating | Yes | |
Auto Resume to Run | Yes | |
Capacity | See optional block | |
Consumption | 150W | |
Power Supply | AC220/110V, 50/60Hz | |
Size (W×D×H)(mm)(Without the Heating Block) | 200x300x210 | |
Shipping Size (W×D×H)(mm) | 400x320x330 | |
N.W./G.W. (kg) | 4/6 |
Precise and efficient temperature control ensures reliable and consistent results in experiments where temperature accuracy is critical.
Rapid cooling characteristics are essential for maintaining sample integrity and saving valuable time in the laboratory workflow.
Adjustable time ranges give users greater flexibility to meet the time requirements of different experiments.
Features a heated lid setting to provide a controlled sample environment, suitable for a wider range of experimental needs.
Temperature uniformity of ≤±0.3°C helps to improve the repeatability and accuracy of experiments.