Availability: | |
---|---|
Quantity: | |
Model | DB-120S | ||
---|---|---|---|
Functions | Heating | ||
Temperature Setting Range (℃) | 25~120 | ||
Temperature Range | RT.+5~120°C | ||
Temperature Control Accuracy (At 37°C) | ± 0.5°C | ||
Temperature Uniformity (At 37°C) | ± 0.5°C | ||
Timer | 0~99h30min | ||
Display | LED | ||
Poer Supply | AC220/110V, 50/60Hz | ||
Consumption | 160W | ||
Size(W×D×H)(mm) | 370x280x180 | ||
Shipping Size(W×D×H)(mm) | 510x370x280 | ||
N.W./G.W. (kg) | 3/5 | ||
Optional blocks | |||
Cat. No. | Block types | Capacity | Diameter |
Depth | |||
Standard: 18900218 Thin: 18900274 | 54×0.2 mL | 6.4 mm 15 mm | |
Standard: 18900219 Thin: 18900275 | 40×0.5 mL | 8.2 mm 26.4 mm | |
Standard: 18900253 Thin: 18900276 | 40×1.5 mL | 11 mm 34.7 mm | |
Standard: 18900220 Thin: 18900277 | 40×2 mL | ||
Standard: 18900221 | 28×5/15 mL | 17 mm 48 mm | |
Standard: 18900546 | 45×5 mL blood collection tube | 13.5 mm 48 mm | |
Standard: 18900222 | 8×50 mL | 29.8 mm 48 mm | |
Standard: 18900224 Thin: 18900278 | 18×0.2mL+18×0.5mL +18×1.5/2mL | \ | |
Standard: 18900223 Thin: 18900279 | 96 or 284 well microplate | \ | |
Thin: 18900504 | 0.2mLx8PCR strips or 0.2mLx96 PCR microplate | \ | |
Thin:18900523 | Two-in-one block, bead bath/water bath | \ |
Wide range of temperature control up to 120°C to meet a wide range of experimental needs
Timer controls up to 99+ hours; users can pre-set the time without continuously monitoring the equipment, improving the convenience and efficiency of experiments.
Various types of optional blocks are available to provide highly accurate temperature control, ensuring the efficiency and accuracy of experiments.
Overheat protection automatically stops heating when the temperature exceeds the set range, minimizing accidents during experiments and protecting the integrity of the samples and the accuracy of the results.
Lid protection prevents sample spillage.
Insulation function ensures the stability and repeatability of the samples during the experiment.
Model | DB-120S | ||
---|---|---|---|
Functions | Heating | ||
Temperature Setting Range (℃) | 25~120 | ||
Temperature Range | RT.+5~120°C | ||
Temperature Control Accuracy (At 37°C) | ± 0.5°C | ||
Temperature Uniformity (At 37°C) | ± 0.5°C | ||
Timer | 0~99h30min | ||
Display | LED | ||
Poer Supply | AC220/110V, 50/60Hz | ||
Consumption | 160W | ||
Size(W×D×H)(mm) | 370x280x180 | ||
Shipping Size(W×D×H)(mm) | 510x370x280 | ||
N.W./G.W. (kg) | 3/5 | ||
Optional blocks | |||
Cat. No. | Block types | Capacity | Diameter |
Depth | |||
Standard: 18900218 Thin: 18900274 | 54×0.2 mL | 6.4 mm 15 mm | |
Standard: 18900219 Thin: 18900275 | 40×0.5 mL | 8.2 mm 26.4 mm | |
Standard: 18900253 Thin: 18900276 | 40×1.5 mL | 11 mm 34.7 mm | |
Standard: 18900220 Thin: 18900277 | 40×2 mL | ||
Standard: 18900221 | 28×5/15 mL | 17 mm 48 mm | |
Standard: 18900546 | 45×5 mL blood collection tube | 13.5 mm 48 mm | |
Standard: 18900222 | 8×50 mL | 29.8 mm 48 mm | |
Standard: 18900224 Thin: 18900278 | 18×0.2mL+18×0.5mL +18×1.5/2mL | \ | |
Standard: 18900223 Thin: 18900279 | 96 or 284 well microplate | \ | |
Thin: 18900504 | 0.2mLx8PCR strips or 0.2mLx96 PCR microplate | \ | |
Thin:18900523 | Two-in-one block, bead bath/water bath | \ |
Wide range of temperature control up to 120°C to meet a wide range of experimental needs
Timer controls up to 99+ hours; users can pre-set the time without continuously monitoring the equipment, improving the convenience and efficiency of experiments.
Various types of optional blocks are available to provide highly accurate temperature control, ensuring the efficiency and accuracy of experiments.
Overheat protection automatically stops heating when the temperature exceeds the set range, minimizing accidents during experiments and protecting the integrity of the samples and the accuracy of the results.
Lid protection prevents sample spillage.
Insulation function ensures the stability and repeatability of the samples during the experiment.