The CO2 incubator has been specifically designed to provide performance reliability, ease of operation and to meet a range of incubation needs from basic research to demanding cutting edge applications.
Precise temperature control--Six-sided heating
High-precision infrared (IR) CO2 sensor
Fast recovery of environment in the incubator
7-inch smart touch screen--real-time monitoring, alarm prompt
180℃ dry heat sterilization
In-situ sterilized HEPA filter--The cleanliness level of the culture room reaches Class A (Class 100 cleanliness) within 5 minutes after closing the door
Antimicrobial powder coating, one-piece inner tank, rounded corner design, no frame, no slide rails, no screws inside, easy to clean
| Model | ICB-C60AH | ICB-C190AH | ICB-C270AH | |
|---|---|---|---|---|
| Capacity(L) | 55 | 185 | 260 | |
| Internal Size (W×D×H)(mm) | 310×380×470 | 500×570×650 | 555×570×832 | |
| External Size (W×D×H)(mm) | 530×635×690 | 715×820×870 | 775×820×1055 | |
| Heating mode | Six-sided heating | |||
| Temperature control range | RT+3~60℃ | |||
| Temperature uniformity | ±0.25℃ | |||
| Temperature fluctuation | ±0.05℃ | |||
| Temperature accuracy | ±0.1℃ | |||
| Temperature recovery (after opening door for 30s) | ≤ 3 min | ≤ 3 min | ≤4 min | |
| Ambient temperature range | 18~34℃ | |||
| CO2 sensor | Infrared (IR) sensor | |||
| CO2 concentration control range | 0~20% | |||
| CO2 control accuracy | ±0.1% | |||
| CO2 concentration recovery (after opening door for 30s) | ≤3 min | ≤3 min | ≤4 min | |
| CO2 inlet pressure | 0.8~1.2bar | |||
| Humidification mode | Natural evaporation | |||
| Relative humidity range | ≥90%RH | |||
| Sterilization mode | 180℃ Dry heat | 180℃ Dry heat | 180℃ Dry heat | |
| Sterilization duration | < 10 hours | |||
| Air intake filter | ≤0.2μm | |||
| Display | 7-inch LCD touch screen | |||
| Door opening method | Left and right interchange | |||
| Material | Internal | 304 mirror stainless steel | ||
| External | Antimicrobial powder coating | |||
| Test hole | Φ32mm | |||
| Shelves | 2 pcs | 3 pcs | 3 pcs | |
| Shelf size (mm) | 305×270 | 496×440 | 550×460 | |
| Shelf load (kg) | 15 | |||
| Power supply | 115/220V, 50/60Hz | |||
| Electricity Consumption (W) | 600 | 1300 | 1600 | |
| Shipping Size (W×D×H)(mm) | 580x690x860 | 770x870x1040 | 835x865x1222 | |
| N.W./G.W. (kg) | 60/70 | 85/105 | 110/120 | |
| Data output interface | USB, RS485 | |||
| Over-temperature protection | Available | |||
| Alarm | High and low temperature alarm, gas concentration alarm, door opening alarm, fault alarm, etc. | |||
| IOT monitoring | Available | |||
Calibration involves temperature and CO₂ concentration. For temperature: place a high-precision thermometer (±0.1°C) inside, let it stabilize, compare readings, and adjust the setpoint if needed (tolerance: ±0.2°C). For CO₂: connect a calibrated CO₂ analyzer to the sampling port, compare its reading to the display, and adjust (tolerance: ±0.1% CO₂). Always let the incubator stabilize for 30 min before calibration. Refer to the manufacturer's manual for specific procedures.
First, turn off power and CO₂ supply, and remove all cultures, shelves, and water pan. Wipe all interior surfaces, door gasket, and shelves with 70% ethanol or mild soap solution. Rinse with sterile distilled water to remove residue. Clean the water pan weekly — empty, wipe with 70% ethanol, and refill with sterile distilled water. For deep decontamination, use a high-temperature sterilization cycle (if available) or wipe with 3‰ benzalkonium chloride, then rinse thoroughly.
CO₂ incubators are primarily used for cell and tissue culture in biomedical research. They maintain a controlled environment at 37°C, 5% CO₂, and ~95% humidity, creating optimal pH (7.2–7.4) for mammalian cell growth. Common applications include cancer research, IVF, stem cell engineering, vaccine production, drug screening, and hybridoma antibody production. They are essential in hospitals, university labs, pharmaceutical, and biotechnology industries.