Availability: | |
---|---|
Quantity: | |
Complies with European Class B standard for effective sterilization.
Automatic door switch for convenient and safe operation.
Microcomputer control with LED display ensures precise and reliable sterilization.
Equipped with BD test, HELIX test, and Vacuum test for comprehensive sterilization performance.
Standard test interface for convenient testing and validation.
Automatic protection function includes over temperature, over pressure, low water level, anti dry burning, and safety door lock.
Safety interlocking device for secure operation.
Three times pre-vacuum enhances sterilization efficiency.
Buzzer reminder and automatic stop after sterilization cycle completion.
Automatic discharge of cold air and steam exhaust for efficient and safe operation.
Built-in steam generator provides quick production of saturated steam.
Built-in printer for record-keeping and documentation.
Model | ST-BA18B | ST-BA24B | ST-BA45B |
Volume | 18L | 24L | 45L |
Power | 2.2kw | 2.2kw | 3.5kw |
Voltage | 220V110V;50/60Hz | ||
Design Pressure | 0.25Mpa | ||
Design Temperature | 139℃ | ||
Rated Working Pressure | 0.22Mpa | ||
Rated Working Temperature | 134℃ | ||
Chamber Volume | Ø250x370 | Ø250x470 | Ø316x615 |
Sizes(WxDxH)(mm) | 620x505x450 | 710x505x450 | 870x657x575 |
Shipping Size(WxDxH)(mm) | 670x560x510 | 760x560x510 | 980x750x630 |
N.W./G.W. (kg) | 53/62 | 58/65 | 105/142 |
Class B autoclave front view
Class B autoclave chamber
Display
Filter and salety valve
2 Years Limited Warranty
1-2 Days Handling and 7-30 Days Shipping
Our Class B autoclaves can typically complete a full sterilisation cycle in approximately 30 minutes. This time may vary slightly depending on the type and quantity of items being processed.
Yes, our benchtop class B autoclave complies with the international EN 13060 standard for effective sterilisation of all types of microorganisms, including bacteria, viruses, fungi and spores.
We provide comprehensive after-sales service support, including maintenance, training, technical support and spare parts supply, etc., to ensure that your class B autoclave is always in the best condition.
Autoclaves usually do not have a fixed time limit for use, but rather a service life based on factors such as the design of the equipment, the materials and the manufacturing process. However, regular maintenance and servicing are important to extend the life of the equipment. It is recommended that you follow the recommendations we have provided for maintenance and strictly follow the instructions in the operating manual during use.
Complies with European Class B standard for effective sterilization.
Automatic door switch for convenient and safe operation.
Microcomputer control with LED display ensures precise and reliable sterilization.
Equipped with BD test, HELIX test, and Vacuum test for comprehensive sterilization performance.
Standard test interface for convenient testing and validation.
Automatic protection function includes over temperature, over pressure, low water level, anti dry burning, and safety door lock.
Safety interlocking device for secure operation.
Three times pre-vacuum enhances sterilization efficiency.
Buzzer reminder and automatic stop after sterilization cycle completion.
Automatic discharge of cold air and steam exhaust for efficient and safe operation.
Built-in steam generator provides quick production of saturated steam.
Built-in printer for record-keeping and documentation.
Model | ST-BA18B | ST-BA24B | ST-BA45B |
Volume | 18L | 24L | 45L |
Power | 2.2kw | 2.2kw | 3.5kw |
Voltage | 220V110V;50/60Hz | ||
Design Pressure | 0.25Mpa | ||
Design Temperature | 139℃ | ||
Rated Working Pressure | 0.22Mpa | ||
Rated Working Temperature | 134℃ | ||
Chamber Volume | Ø250x370 | Ø250x470 | Ø316x615 |
Sizes(WxDxH)(mm) | 620x505x450 | 710x505x450 | 870x657x575 |
Shipping Size(WxDxH)(mm) | 670x560x510 | 760x560x510 | 980x750x630 |
N.W./G.W. (kg) | 53/62 | 58/65 | 105/142 |
Class B autoclave front view
Class B autoclave chamber
Display
Filter and salety valve
2 Years Limited Warranty
1-2 Days Handling and 7-30 Days Shipping
Our Class B autoclaves can typically complete a full sterilisation cycle in approximately 30 minutes. This time may vary slightly depending on the type and quantity of items being processed.
Yes, our benchtop class B autoclave complies with the international EN 13060 standard for effective sterilisation of all types of microorganisms, including bacteria, viruses, fungi and spores.
We provide comprehensive after-sales service support, including maintenance, training, technical support and spare parts supply, etc., to ensure that your class B autoclave is always in the best condition.
Autoclaves usually do not have a fixed time limit for use, but rather a service life based on factors such as the design of the equipment, the materials and the manufacturing process. However, regular maintenance and servicing are important to extend the life of the equipment. It is recommended that you follow the recommendations we have provided for maintenance and strictly follow the instructions in the operating manual during use.