Quantity: | |
Model | ST-B45B |
Capacity | 45L |
External Size(WxDxH) | 870x600x520mm |
Chamber Size(ØxH) | Ø316x590mm |
Chamber Material | SUS304 |
Sterilization Temperature | 105~136 ℃ |
Designed Temperature | 150℃ |
Max.Working Temperature | 136 ℃ |
Temp.Accuracy | 0.1℃ |
Temp.Uniformity | ≤±0.5℃ |
Designed Pressure | -0.1/0.3Mpa |
Sterilization Pressure | 0.23Mpa |
Pressure Resoluiton | 0.1KPa |
Ultimate Vacuum | -0.096MPa |
Temp. Controller | PID control by microprocessor |
Display | LCD touch screen |
Drying Function | YES |
Drying Time | 15min |
Sterilization Program | ●Medical instrument program Sterilization of medical dressing, medical Instruments, Instruments with cavity, Rubber, liquids plus 4 user-customized programs BD Test and vacuum test. |
Water Injection Method | Built-in water tank |
Power Consumption | 3.6KW |
Power Supply | 220V 50Hz |
Standard Sterilization Shelf | 1pcs SS shelf |
Optional Accessories | printer |
Net Weight | 65kg |
Gross Weight | 120kg |
Shipping Size(WxDxH) | 1150x700x700mm |
Overheat protection: Automatically cutting off heating with audible and visual alarming when the autoclave is overheated.
Interlock safety: Preventing from starting a cycle if door is not properly locked or from door opening if the chamber is pressurized.
Anti-burning protection: Automatically cutting off heating with audible and visual indication when the autoclave is lack of water.
Steam pressure safety valve: Automatically works when the chamber pressure exceeds the limit.
Automatic operation from sterilization to drying (Pre-vacuum sequence, heating, sterilization, steam discharge and post-vacuum drying) can be easily set and monitored by LCD touch screen.
Built-in vacuum pump provides 3-time pulsed vacuum process,extracting the air out of the medical dressing and the A degree hollow medical instrument efficiently.
Built-in steam generator prevents the media from contamination.
Post-vacuum drying function offers efficient drying results.
Positive pulsing function removes the air efficiently.
With 0.22µm air filter, blocks all microorganisms from exiting the chamber during the air removal phase.
Optional printer, real-time record sterilization process, error and alarm information.
Model | ST-B45B |
Capacity | 45L |
External Size(WxDxH) | 870x600x520mm |
Chamber Size(ØxH) | Ø316x590mm |
Chamber Material | SUS304 |
Sterilization Temperature | 105~136 ℃ |
Designed Temperature | 150℃ |
Max.Working Temperature | 136 ℃ |
Temp.Accuracy | 0.1℃ |
Temp.Uniformity | ≤±0.5℃ |
Designed Pressure | -0.1/0.3Mpa |
Sterilization Pressure | 0.23Mpa |
Pressure Resoluiton | 0.1KPa |
Ultimate Vacuum | -0.096MPa |
Temp. Controller | PID control by microprocessor |
Display | LCD touch screen |
Drying Function | YES |
Drying Time | 15min |
Sterilization Program | ●Medical instrument program Sterilization of medical dressing, medical Instruments, Instruments with cavity, Rubber, liquids plus 4 user-customized programs BD Test and vacuum test. |
Water Injection Method | Built-in water tank |
Power Consumption | 3.6KW |
Power Supply | 220V 50Hz |
Standard Sterilization Shelf | 1pcs SS shelf |
Optional Accessories | printer |
Net Weight | 65kg |
Gross Weight | 120kg |
Shipping Size(WxDxH) | 1150x700x700mm |
Overheat protection: Automatically cutting off heating with audible and visual alarming when the autoclave is overheated.
Interlock safety: Preventing from starting a cycle if door is not properly locked or from door opening if the chamber is pressurized.
Anti-burning protection: Automatically cutting off heating with audible and visual indication when the autoclave is lack of water.
Steam pressure safety valve: Automatically works when the chamber pressure exceeds the limit.
Automatic operation from sterilization to drying (Pre-vacuum sequence, heating, sterilization, steam discharge and post-vacuum drying) can be easily set and monitored by LCD touch screen.
Built-in vacuum pump provides 3-time pulsed vacuum process,extracting the air out of the medical dressing and the A degree hollow medical instrument efficiently.
Built-in steam generator prevents the media from contamination.
Post-vacuum drying function offers efficient drying results.
Positive pulsing function removes the air efficiently.
With 0.22µm air filter, blocks all microorganisms from exiting the chamber during the air removal phase.
Optional printer, real-time record sterilization process, error and alarm information.