Model | BII-80 | |
---|---|---|
Temp. Control Range | RT+5~100℃ | |
Timing Range | 1min~999h | |
Temp. Accuracy | ≤±0.3℃ | |
Display Accuracy | 0.1℃ | |
Heating Time | ≤6min (From 20℃ to 56℃) | |
Ambient Temperature | 5℃~35℃ | |
Consumption | 40W | |
Power Supply | AC220/110V, 50/60Hz | |
Size (W×D×H)(mm) | 145×113×110 | |
Shipping Size (W×D×H)(mm) | 290x250x220 | |
N.W./G.W. (kg) | 0.5/2 | |
Optional Blocks | ||
Type | Diameter | Capacity |
MD40 | Φ10mm | 15 |
MD41 | Φ12mm | 12 |
MD42 | Φ15mm | 8 |
MD43 | Φ16mm | 8 |
MD45 | Φ9mm | 18 |
BII-80 bioindicator indicator incubator is versatile, compact, reliable and easy to use. Designed for single-temperature incubation of EO bioindicators. Thermometer is included in the incubator for easy verification of incubation temperature.
Energy-efficient design greatly reduces operating costs and energy waste
Temperature control is accurate to ±0.3°C, ensuring accurate and reliable incubation of bioindicators
Visualization of the experimental process allows real-time detection of the bioindicator incubation situation
Electronic calibration ensures that the temperature inside the incubator is the same as the set value, improving the reproducibility of experiments
Customized to fit any sample rack for greater operational flexibility
Power supply is UL, CSA and CE certified
Model | BII-80 | |
---|---|---|
Temp. Control Range | RT+5~100℃ | |
Timing Range | 1min~999h | |
Temp. Accuracy | ≤±0.3℃ | |
Display Accuracy | 0.1℃ | |
Heating Time | ≤6min (From 20℃ to 56℃) | |
Ambient Temperature | 5℃~35℃ | |
Consumption | 40W | |
Power Supply | AC220/110V, 50/60Hz | |
Size (W×D×H)(mm) | 145×113×110 | |
Shipping Size (W×D×H)(mm) | 290x250x220 | |
N.W./G.W. (kg) | 0.5/2 | |
Optional Blocks | ||
Type | Diameter | Capacity |
MD40 | Φ10mm | 15 |
MD41 | Φ12mm | 12 |
MD42 | Φ15mm | 8 |
MD43 | Φ16mm | 8 |
MD45 | Φ9mm | 18 |
BII-80 bioindicator indicator incubator is versatile, compact, reliable and easy to use. Designed for single-temperature incubation of EO bioindicators. Thermometer is included in the incubator for easy verification of incubation temperature.
Energy-efficient design greatly reduces operating costs and energy waste
Temperature control is accurate to ±0.3°C, ensuring accurate and reliable incubation of bioindicators
Visualization of the experimental process allows real-time detection of the bioindicator incubation situation
Electronic calibration ensures that the temperature inside the incubator is the same as the set value, improving the reproducibility of experiments
Customized to fit any sample rack for greater operational flexibility
Power supply is UL, CSA and CE certified