| Availability: | |
|---|---|
| Quantity: | |
Advantage:
1. Automatic controlling procedure, time of power on/off can be reset in any time of each day weekly.
2. Adopted with new-type silastic heating element,heated quikly and evenly, energy-saving.
3. American DALLAS temperature-measuring chip,high precision,stable performance, display as icon in the state of working.
4. Paraffin chamber, paraffin distributor, thermal chamber, working table can be separately controlled, work independently. Five different modes of controlling temperature and multi-ply over-heating protection, safe, reliable, and energy-saving.
5. Automatic memorization and self-recovery reserving resetting temperature when starting up.
6. Embedded tissue can be freezed at small cooling plate with the instrument.
7. High capacity (5 liters) paraffin chamber can finish tissue-embedding one time.
8. Low-voltage lighting system, safe and reliable.
9. 2 modes of switch: automatic soft-touch and foot-operated.
10. Workstation and forceps holders can be heated, making it easy for embedding.
11. High-precision time indication,easy to reset.
Specification:
Model | TE-III&CS-III | |
Paraffin Chamber Capacity | 5 L | |
Temperature Range | Forceps Holder | RT-99 ℃ |
Paraffin Chamber | ||
Left Thermal Chamber | ||
Right Thermal Chamber | ||
Working Table | ||
Paraffin Distributor | ||
Cold Plate | +5 to -35 ℃ | |
Small Cooling Plate | < -5 ℃ | |
Temperature Control Precision | ± 1℃ | |
Paraffin Flow Control | Automatic soft-touch switch, foot-operated switch | |
Fully Programmable ON/OFF Control | Allows automatic system start and stop anytime weekly | |
Safety Protection | Double overheat protection device | |
Automatic Memory Recovery Function | Yes | |
Working Area Size | Thermal Chamber | 240×160×55 mm |
Working Table | 150×90 mm | |
Small Cooling Plate | 60×50 mm | |
Cold Plate | 330×322 mm | |
Power Supply | AC 220 V ± 10%, 50 Hz (standard model); AC 110 V ± 10%, 60 Hz | |
Power | 800 W (TE-III) | |
300 W (CS-III) | ||
Dimensions Size (W×D×H) | 650×580×450 mm (TE-III) | |
650×380×450 mm (CS-III) | ||
Shipping Size (W×D×H) | 770×690×610 mm (TE-III ) | |
800×480×580 mm (CS-III) | ||
N.W. /G.W. | 40/45 kg (TE-III) | |
29/36 kg (CS-III) | ||
Advantage:
1. Automatic controlling procedure, time of power on/off can be reset in any time of each day weekly.
2. Adopted with new-type silastic heating element,heated quikly and evenly, energy-saving.
3. American DALLAS temperature-measuring chip,high precision,stable performance, display as icon in the state of working.
4. Paraffin chamber, paraffin distributor, thermal chamber, working table can be separately controlled, work independently. Five different modes of controlling temperature and multi-ply over-heating protection, safe, reliable, and energy-saving.
5. Automatic memorization and self-recovery reserving resetting temperature when starting up.
6. Embedded tissue can be freezed at small cooling plate with the instrument.
7. High capacity (5 liters) paraffin chamber can finish tissue-embedding one time.
8. Low-voltage lighting system, safe and reliable.
9. 2 modes of switch: automatic soft-touch and foot-operated.
10. Workstation and forceps holders can be heated, making it easy for embedding.
11. High-precision time indication,easy to reset.
Specification:
Model | TE-III&CS-III | |
Paraffin Chamber Capacity | 5 L | |
Temperature Range | Forceps Holder | RT-99 ℃ |
Paraffin Chamber | ||
Left Thermal Chamber | ||
Right Thermal Chamber | ||
Working Table | ||
Paraffin Distributor | ||
Cold Plate | +5 to -35 ℃ | |
Small Cooling Plate | < -5 ℃ | |
Temperature Control Precision | ± 1℃ | |
Paraffin Flow Control | Automatic soft-touch switch, foot-operated switch | |
Fully Programmable ON/OFF Control | Allows automatic system start and stop anytime weekly | |
Safety Protection | Double overheat protection device | |
Automatic Memory Recovery Function | Yes | |
Working Area Size | Thermal Chamber | 240×160×55 mm |
Working Table | 150×90 mm | |
Small Cooling Plate | 60×50 mm | |
Cold Plate | 330×322 mm | |
Power Supply | AC 220 V ± 10%, 50 Hz (standard model); AC 110 V ± 10%, 60 Hz | |
Power | 800 W (TE-III) | |
300 W (CS-III) | ||
Dimensions Size (W×D×H) | 650×580×450 mm (TE-III) | |
650×380×450 mm (CS-III) | ||
Shipping Size (W×D×H) | 770×690×610 mm (TE-III ) | |
800×480×580 mm (CS-III) | ||
N.W. /G.W. | 40/45 kg (TE-III) | |
29/36 kg (CS-III) | ||