Model | MPI-500 |
---|---|
Temp. Display Range | 0℃~80℃ |
Temp Control Range | RT.+5~80℃ |
Time Range | 1min~99h59min |
Temp. Accuracy | ≤±0.5℃ |
Display Accuracy | 0.1℃ |
Temp Uniformity | ≤±0.5℃ |
Heating Time | ≤10min (From 25℃ to 80℃) |
Auto Preheating | Yes |
Auto Resume to Run | Yes |
Capacity | 4 Microplates or Deep well plates |
Consumption | 300W |
Power Supply | AC220V/110V, 50/60Hz |
Size(W×D×H)(mm) | 340x320x200 |
Shipping Size(W×D×H)(mm) | 500x470x330 |
N.W./G.W. (kg) | 6.5/8 |
DH500 microplate incubator adopts PID fuzzy control technology, which can accurately ensure the precision of temperature control and automatically adjust the rate of temperature rise to reduce the waiting time. It is the preferred tool for sample preservation, mixing, incubation and other catalytic reaction processes.
It supports standard microplates and deep-well plates, providing a wider choice of experimental applications to meet the needs of different types of experiments.
Automatic warm-up function saves time and improves efficiency.
Auto power-off recovery function automatically restores the previously set parameters after a power failure, avoiding experiment interruption and data loss.
Temperature calibration function improves the accuracy of temperature measurement.
Built-in hardware and software over-temperature protection devices can monitor and control the temperature to prevent the temperature from exceeding the safety range.
Model | MPI-500 |
---|---|
Temp. Display Range | 0℃~80℃ |
Temp Control Range | RT.+5~80℃ |
Time Range | 1min~99h59min |
Temp. Accuracy | ≤±0.5℃ |
Display Accuracy | 0.1℃ |
Temp Uniformity | ≤±0.5℃ |
Heating Time | ≤10min (From 25℃ to 80℃) |
Auto Preheating | Yes |
Auto Resume to Run | Yes |
Capacity | 4 Microplates or Deep well plates |
Consumption | 300W |
Power Supply | AC220V/110V, 50/60Hz |
Size(W×D×H)(mm) | 340x320x200 |
Shipping Size(W×D×H)(mm) | 500x470x330 |
N.W./G.W. (kg) | 6.5/8 |
DH500 microplate incubator adopts PID fuzzy control technology, which can accurately ensure the precision of temperature control and automatically adjust the rate of temperature rise to reduce the waiting time. It is the preferred tool for sample preservation, mixing, incubation and other catalytic reaction processes.
It supports standard microplates and deep-well plates, providing a wider choice of experimental applications to meet the needs of different types of experiments.
Automatic warm-up function saves time and improves efficiency.
Auto power-off recovery function automatically restores the previously set parameters after a power failure, avoiding experiment interruption and data loss.
Temperature calibration function improves the accuracy of temperature measurement.
Built-in hardware and software over-temperature protection devices can monitor and control the temperature to prevent the temperature from exceeding the safety range.