Availability: | |
---|---|
Quantity: | |
Model | BII-1000/BII-1000S |
---|---|
Temp. Setting Range | 0℃~100℃ |
Temp. Control Range | RT+5℃~100℃ |
Time Range | 1min~99h59min |
Temp. Accuracy | ≤±0.3℃ |
Display. Accuracy | 0.1℃ |
Temp. Uniformity | ≤±0.3℃ |
Heating Time | ≤12min (From 25℃ to 100℃) |
Automatic Running | Yes |
Capacity | See optional block |
Consumption | 150W |
Power Supply | AC220/110V, 50/60Hz |
Size(W×D×H)(mm) | 260x195x150 |
Shipping Size(W×D×H)(mm) | 410x320x320 |
N.W./G.W. (kg) | 2.5/4 |
Optional Blocks | |
Type | Capacity |
RCO2044001 | 35xΦ9mm Only for BII-1000 |
RCO2044002 | 35xΦ10mm Only for BII-1000 |
RC02 044 003 | 28xΦ12mm Only for BII-1000S |
BII-1000/BII-1000S is a sample incubation equipment based on PID automatic control and thermofilm heating technology. The constant temperature and independent timer function improve the efficiency of laboratory work and are ideal for bio-indicator incubation.
Easy to set up and use. All information and parameters can be set in real-time.
High-precision temperature control provides a stable temperature environment for the incubator.
Wide time range for different types of bio-indicator incubations
Up to 7 groups of samples can be incubated at a time, and each group can be counted down independently to improve significantly the reliability of the bio-indicator.
Autorun function simplifies the operation process and human intervention, ensuring the consistency of the experiment.
Temperature calibration function ensures that the temperature inside the incubator is consistent with the set value.
Built-in software and hardware over-temperature protection devices for more reliable use.
Model | BII-1000/BII-1000S |
---|---|
Temp. Setting Range | 0℃~100℃ |
Temp. Control Range | RT+5℃~100℃ |
Time Range | 1min~99h59min |
Temp. Accuracy | ≤±0.3℃ |
Display. Accuracy | 0.1℃ |
Temp. Uniformity | ≤±0.3℃ |
Heating Time | ≤12min (From 25℃ to 100℃) |
Automatic Running | Yes |
Capacity | See optional block |
Consumption | 150W |
Power Supply | AC220/110V, 50/60Hz |
Size(W×D×H)(mm) | 260x195x150 |
Shipping Size(W×D×H)(mm) | 410x320x320 |
N.W./G.W. (kg) | 2.5/4 |
Optional Blocks | |
Type | Capacity |
RCO2044001 | 35xΦ9mm Only for BII-1000 |
RCO2044002 | 35xΦ10mm Only for BII-1000 |
RC02 044 003 | 28xΦ12mm Only for BII-1000S |
BII-1000/BII-1000S is a sample incubation equipment based on PID automatic control and thermofilm heating technology. The constant temperature and independent timer function improve the efficiency of laboratory work and are ideal for bio-indicator incubation.
Easy to set up and use. All information and parameters can be set in real-time.
High-precision temperature control provides a stable temperature environment for the incubator.
Wide time range for different types of bio-indicator incubations
Up to 7 groups of samples can be incubated at a time, and each group can be counted down independently to improve significantly the reliability of the bio-indicator.
Autorun function simplifies the operation process and human intervention, ensuring the consistency of the experiment.
Temperature calibration function ensures that the temperature inside the incubator is consistent with the set value.
Built-in software and hardware over-temperature protection devices for more reliable use.