Availability: | |
---|---|
Model | ST-VM56 ST-VY56 | ST-VM80 ST-VY80 | ST-VM75/ST-VY75 | ST-VM105/ST-VY105 | ST-VM120/ST-VY120 | ST-VM95/ST-VY95 | ST-VM135/ST-VY135 | ST-VM150/ST-VY150 |
---|---|---|---|---|---|---|---|---|
ST-VM Series: Normal Type ST-VY Series: Drying Function Type | ||||||||
Capacity | 56L | 80L | 75L | 105L | 120L | 95L | 135L | 150L |
External Size (WxDxH)(mm) | 680x600 x895 | 680x600 x1145 | 680x600 x895 | 680x600x 1145 | 680x600 x1235 | 680x600 x895 | 680x600 x1145 | 680x600 x1145 |
Chamber Size (ØxH)(mm) | Ø350x645 | Ø350x895 | Ø400x661 | Ø400x911 | Ø400x1001 | Ø450x677 | Ø450x927 | Ø450x1017 |
Chamber Material | S30408 | |||||||
Sterilization Temperature | 105~135 ℃ | |||||||
Designed Temperature | 138℃ | |||||||
Max.Working Temperature | 135℃ | |||||||
Dissolution Temperature | 60~100℃ | |||||||
Warming Temperature | 45~65℃ | |||||||
Unlock Temperature | 60~95℃ | |||||||
Temp.Accuracy | 0.1℃ | |||||||
Designed Pressure | 0.42Mpa | 0.42Mpa | 0.38Mpa | 0.38Mpa | 0.38Mpa | 0.35Mpa | 0.35Mpa | 0.35Mpa |
Max.Sterilization Pressure | 0.24Mpa | |||||||
Sterilization Time Range | 1~9999min | |||||||
Temp. Controller | PID control by microprocessor | |||||||
Display | LED screen | |||||||
Drying Function | 3 Optional Drying Solutions (Select 1): Thermal control drying drying Positive pressure drying Vacuum drying | |||||||
Drying Time | 10~300min (Optional) | |||||||
Sterilization Program | ●Liquid program ●Liquid & insulation program ●Bagged waste ●Dissolution & insulation program ●Instrument program ●Self-cleaning program ●Safety valve test program ●Leakage test program ●B-D test program | |||||||
Water Injection Method | Build-in water tank Optional: Water supply pipeline+automatic replenishment, filtered pure water+automatic replenishment, positive pressure automatic drainage in the chamber, automatic detection and removal of discharged wastewater | |||||||
Power Consumption | 2500W | 3800W | 2500W | 3800W | 3800W | 3800W | 3800W | 3800W |
Power Supply | 220V 50/60Hz 10A/16A | 220V 50/60Hz 16A | 220V 50/60Hz 16A | 220V 50/60Hz 25A | 220V 50/60Hz 25A | 220V 50/60Hz 25A | 220V 50/60Hz 25A | 220V 50/60Hz 25A |
Standard | ●USB port ●Buli-in water tank ●User management | |||||||
Optional | ●Printer (Impact) ●PTFE filter ●Sample temperature sensor ●Electric drainage ●Water supply pipe ●Bulid-in waste tank ●Positive pressure compensation ●Auto un-lock and door open ●Leakage test module ●Vacuum test module ●Water cooling system | |||||||
Drying Power Consumption | 700W | 900W | 1200W | 1400W | 1600W | 1200W | 1400W | 1600W |
Automatically detect the position of the door lock and provide voice-guided instructions for easy operation.
Blue breathing light indicates standby, alert, and power outage statuses.
Safety valve calibration prompts, with the ability to send notification messages to a WeChat public account through cloud-based pushing.
Dual-hold electromagnetic locks ensure automatic locking under high temperature or pressure. Unlock conditions are met for automatic release, and the lid can be opened directly by lifting the lever.
No steam leakage: Internal integration of copper pipe steam condenser converts high-temperature steam into water before discharging it into the waste steam collection tank.
Voice prompts and guidance for user-friendly operation.
Optional sterilization report USB export and online storage of sterilization reports.
Free computer software provided for generating sterilization reports, allowing data exported from the USB drive to be output as PDF reports. Can generate reports in both graphical and data formats.
PHM/PHY models are equipped with online sterilization quality control functions such as "FO value calculation, FO value process calculation, FO value aging treatment."
Full automatic water replenishment, built-in current detection module to monitor the operation status of the heater in real-time, preventing dry heating online.
Standard configuration: Dual over-temperature protection + dual over-pressure protection for the heating system, ensuring enhanced safety.
Expandable + optional: For positive waste sterilization, an optional PTFE filter can be added to prevent exhaust pollution and potential personnel poisoning.
Reservation and preheating: Time reservation for automatic sterilization. Preheating capability prevents condensation due to temperature drop after drying.
Rapidly Cooling: Standard Configuration: Dual-cycle air cooling can shorten the cooling time. For fragile objects, when combined with positive pressure, maintaining pressure and quick air cooling can enhance efficiency. The FO value is automatically calculated to determine if sterilization is effective. Sterilization completion can be determined based on FO value rather than time.
Disinfection packages with moisture content greater than 3% are referred to as wet packs. Wet packs cannot be used and must be re-sterilized. The reason is that the moisture in the air forms a wet channel for bacterial contamination, leading to internal infection.
Replaces the need for an oven, saving space.
Simplifies complexity, saving time.
Eliminates secondary contamination during the transfer process.
Model | ST-VM56 ST-VY56 | ST-VM80 ST-VY80 | ST-VM75/ST-VY75 | ST-VM105/ST-VY105 | ST-VM120/ST-VY120 | ST-VM95/ST-VY95 | ST-VM135/ST-VY135 | ST-VM150/ST-VY150 |
---|---|---|---|---|---|---|---|---|
ST-VM Series: Normal Type ST-VY Series: Drying Function Type | ||||||||
Capacity | 56L | 80L | 75L | 105L | 120L | 95L | 135L | 150L |
External Size (WxDxH)(mm) | 680x600 x895 | 680x600 x1145 | 680x600 x895 | 680x600x 1145 | 680x600 x1235 | 680x600 x895 | 680x600 x1145 | 680x600 x1145 |
Chamber Size (ØxH)(mm) | Ø350x645 | Ø350x895 | Ø400x661 | Ø400x911 | Ø400x1001 | Ø450x677 | Ø450x927 | Ø450x1017 |
Chamber Material | S30408 | |||||||
Sterilization Temperature | 105~135 ℃ | |||||||
Designed Temperature | 138℃ | |||||||
Max.Working Temperature | 135℃ | |||||||
Dissolution Temperature | 60~100℃ | |||||||
Warming Temperature | 45~65℃ | |||||||
Unlock Temperature | 60~95℃ | |||||||
Temp.Accuracy | 0.1℃ | |||||||
Designed Pressure | 0.42Mpa | 0.42Mpa | 0.38Mpa | 0.38Mpa | 0.38Mpa | 0.35Mpa | 0.35Mpa | 0.35Mpa |
Max.Sterilization Pressure | 0.24Mpa | |||||||
Sterilization Time Range | 1~9999min | |||||||
Temp. Controller | PID control by microprocessor | |||||||
Display | LED screen | |||||||
Drying Function | 3 Optional Drying Solutions (Select 1): Thermal control drying drying Positive pressure drying Vacuum drying | |||||||
Drying Time | 10~300min (Optional) | |||||||
Sterilization Program | ●Liquid program ●Liquid & insulation program ●Bagged waste ●Dissolution & insulation program ●Instrument program ●Self-cleaning program ●Safety valve test program ●Leakage test program ●B-D test program | |||||||
Water Injection Method | Build-in water tank Optional: Water supply pipeline+automatic replenishment, filtered pure water+automatic replenishment, positive pressure automatic drainage in the chamber, automatic detection and removal of discharged wastewater | |||||||
Power Consumption | 2500W | 3800W | 2500W | 3800W | 3800W | 3800W | 3800W | 3800W |
Power Supply | 220V 50/60Hz 10A/16A | 220V 50/60Hz 16A | 220V 50/60Hz 16A | 220V 50/60Hz 25A | 220V 50/60Hz 25A | 220V 50/60Hz 25A | 220V 50/60Hz 25A | 220V 50/60Hz 25A |
Standard | ●USB port ●Buli-in water tank ●User management | |||||||
Optional | ●Printer (Impact) ●PTFE filter ●Sample temperature sensor ●Electric drainage ●Water supply pipe ●Bulid-in waste tank ●Positive pressure compensation ●Auto un-lock and door open ●Leakage test module ●Vacuum test module ●Water cooling system | |||||||
Drying Power Consumption | 700W | 900W | 1200W | 1400W | 1600W | 1200W | 1400W | 1600W |
Automatically detect the position of the door lock and provide voice-guided instructions for easy operation.
Blue breathing light indicates standby, alert, and power outage statuses.
Safety valve calibration prompts, with the ability to send notification messages to a WeChat public account through cloud-based pushing.
Dual-hold electromagnetic locks ensure automatic locking under high temperature or pressure. Unlock conditions are met for automatic release, and the lid can be opened directly by lifting the lever.
No steam leakage: Internal integration of copper pipe steam condenser converts high-temperature steam into water before discharging it into the waste steam collection tank.
Voice prompts and guidance for user-friendly operation.
Optional sterilization report USB export and online storage of sterilization reports.
Free computer software provided for generating sterilization reports, allowing data exported from the USB drive to be output as PDF reports. Can generate reports in both graphical and data formats.
PHM/PHY models are equipped with online sterilization quality control functions such as "FO value calculation, FO value process calculation, FO value aging treatment."
Full automatic water replenishment, built-in current detection module to monitor the operation status of the heater in real-time, preventing dry heating online.
Standard configuration: Dual over-temperature protection + dual over-pressure protection for the heating system, ensuring enhanced safety.
Expandable + optional: For positive waste sterilization, an optional PTFE filter can be added to prevent exhaust pollution and potential personnel poisoning.
Reservation and preheating: Time reservation for automatic sterilization. Preheating capability prevents condensation due to temperature drop after drying.
Rapidly Cooling: Standard Configuration: Dual-cycle air cooling can shorten the cooling time. For fragile objects, when combined with positive pressure, maintaining pressure and quick air cooling can enhance efficiency. The FO value is automatically calculated to determine if sterilization is effective. Sterilization completion can be determined based on FO value rather than time.
Disinfection packages with moisture content greater than 3% are referred to as wet packs. Wet packs cannot be used and must be re-sterilized. The reason is that the moisture in the air forms a wet channel for bacterial contamination, leading to internal infection.
Replaces the need for an oven, saving space.
Simplifies complexity, saving time.
Eliminates secondary contamination during the transfer process.