| Availability: | |
|---|---|
| Model | SP-18AB | SP-24AB |
|---|---|---|
| Input power/ frequency | 220V/50Hz | 220V/50Hz |
| Power (KW) | 2KW | 2KW |
| Volume (L) | 18L | 24L |
| Working pressure (MPa) | 0.142MPa | 0.142MPa |
| Maximum pressure (MPa) | 0.165MPa | 0.165MPa |
| Working temperature (℃) | 126 | 126 |
| Maximum sterilization temperature (℃) | 129 | 129 |
| Pressure display mode | Pressure gauge display/dual scale pressure gauge | Pressure gauge display/dual scale pressure gauge |
| Temperature display mode | LED display | LED display |
| Heating method | electricity to prevent dry burning | electricity to prevent dry burning |
| Sterilization time range min | 0-60min | 0-60min |
| Sterilization chamber size | Φ280x235mm | Φ280x340mm |
| Packaging size (L×W×H)(mm) | 400x400x540 | 400x400x670 |
| Net weight | 12.5Kg | 13.5Kg |
| Gross weight | 16kg | 17Kg |
| Material (stainless steel type) | Inner liner: 201 stainless steel, outer bucket : 304 stainless steel | Inner liner: 201 stainless steel, outer bucket : 304 stainless steel |
| Usage environment | Temperature 5 ℃ -40 ℃, humidity ≤ 80% | Temperature 5 ℃ -40 ℃, humidity ≤ 80% |
| Power cord length | 1.7-1.8m | 1.7-1.8m |
Thickened stainless steel material, with a barrel thickness of 2mm, durable and long-lasting;
Microcomputer intelligent control, capable of regulating temperature and time; The display screen shows the sterilization temperature and time clearly and distinctly. Automatically stop heating and sound an alarm at the end of sterilization, easy to operate;
The safety interlock displacement quick opening cover structure cannot be opened under internal pressure, making it safe and convenient to use;
Portable autoclave is equipped with a liquid level gauge and a low water level alarm function, it automatically stops heating and alarms when the water level is low, effectively protecting the equipment;
Equipped with a dual scale pressure gauge, it displays both internal pressure and temperature simultaneously, providing intuitive and accurate readings of parameters;
Equipped with a fully open safety valve and a relief valve, it can automatically release overpressure and maintain constant pressure, ensuring safety and reliability;
Portable autoclave is equipped with over temperature and over pressure protection devices, the circuit board has over voltage protection device and automatic power-off alarm function when the temperature reaches the upper limit, with high safety;
Adopting immersion stainless steel electric heating tube for longer service life;
Self expanding sealing ring, safer and more convenient;
Adopting faucet drainage; Avoid burns;