Application:
The Microvolume UV-Vis Spectrophotometer is designed for the rapid and accurate quantification of microvolumes in genomics, proteomics, molecular biology, biotechnology, pharmaceuticals and life sciences research. The instrument also includes a built-in fluorescence module, capable of measuring fluorescence intensity, supporting Ion Sphere mode, and providing customizable options like excitation/emission light sources and fluorescence kinetics. Perfect for high-throughput labs and those requiring small sample volumes, it ensures accurate results with minimal sample waste.
Advantage:
1. Supports USB data output, can connect to Ethernet, Bluetooth and WI-FI
2. Output ports: Equipped with 2 USB-A interfaces, 1 Type C interface, 1 HDMI, and 1 Ethernet port, it can be used to connect with various devices such as mice, keyboards, desktop computers, etc
3. Spectral chart function with one click export of scan detection results
4. Fluorescence detection has a custom standard curve module, which can be more freely compatible with more reagent kits and experimental methods
5. Fluorescence detection has a kinetic module that can perform fluorescence kinetic detection and draw kinetic curves
6. The colloidal gold module has a unique automatic peak detection function, which can automatically search for the characteristic wavelengths of colloidal gold with different particle sizes
7. The standard curve has multiple fitting methods to meet diverse experimental needs
Specification:
| Model | SP-MUV5900I | |
| Performance Parameter | Light source | Longevity lifeline xenon flashing light (10⁹ times) |
| Detector | 2048 (coms) linear image sensor | |
| Detection wavelength range | 190–850 nm | |
| Xenon lamp photometric range | 185–2000 nm | |
| Wavelength accuracy | ±1 nm | |
| Wavelength resolution | 2 nm (FWHM at Hg 254 nm) | |
| Accuracy of absorbance | 1% (0.988 absorbance at 257 nm) | |
| Monitor | 10.1-inch touch screen, multi-point capacitive touch screen | |
| Detection time | Less than 3 seconds | |
| Optical path | Ultra trace mode 1, 0.4, 0.1, 0.04, 0.02 mm (optical path automatic conversion) | |
| Cuvette mode 10, 5, 2, 1 mm | ||
| Volume requirements | Ultra trace 0.3–2 μL | |
| Cuvette dish ≥ 1000 μL (10 mm optical path) | ||
| Range of absorbance | Ultra trace mode 0–800 Abs (equivalent to 10 mm optical path) | |
| Cuvette mode 0–16 Abs (equivalent to 10 mm optical path) | ||
| Concentration measurement range | Ultra trace: 2–40000 ng/μL (dsDNA) | |
| Cuvette (10 mm): 0.2–80 ng/μL (dsDNA) | ||
| Detecting repeatability | 0.002 A (1 mm optical path) or 1% CV | |
| Equipped with automatic measurement and zero adjustment functions, the detection arm can be lowered to achieve real-time detection; | ||
| Equipped with intelligent sample detection function, it provides information prompts and pollutant types upon discovering pollutants. The types of pollutants that can be identified include at least: protein, nucleic acid, phenol, guanidine isothiocyanate, and guanidine hydrochloride. And it has a result correction function, which can provide the original concentration of the sample, the corrected concentration, and the type of pollutant. Ensure the accurate concentration and quality of the sample, and guarantee the accuracy and best experimental results of the experiment | ||
| The nucleic acid testing module includes | dsDNA, SsDNA, RNA, User settings oligoDNA, oligoRNA , Gene chip module | |
| The protein detection module includes | A280, Peptide, protein chip, BCA, Bradford, Lowry, Pierce660 module | |
| The 0D600 module includes | Cell fluid module | |
| Custom modules include | Full wavelength, standard curve, colloidal gold, kinetic module | |
| The standard curve has multiple curve fitting functions | Linear, interpolation, second-order polynomial, third-order polynomial | |
| Can perform full wavelength colorimetric dish absorption light detection | ||
| Flexible dynamic module that can achieve dynamic detection in 5 stages, with customizable delay time, interval time, and detection frequency | ||
| Fluorescent Module | Excitation wavelength range | 190–1000 nm |
| Emission wavelength range | 280–850 nm | |
| Excitation filter | Standard configuration 355, 485, 544, 646 nm | |
| Emission filter | Standard configuration 460, 538, 590, 678 nm | |
| Detector | Photodiode (320–1100 nm) | |
| Sample flux | 1 piece | |
| Sample dosage | 1–20 μL | |
| Tube type | 0.5 mL PCR tube | |
| Tube sampling volume | ≥100 μL | |
| Warm-up time | No preheating required | |
| Measurement speed | 3s/tube | |
| Linear | R²≥0.995 | |
| Linear range | 5 orders of magnitude | |
| Built in reagent calculator to calculate the required amount of dye and buffer solution for the working solution | ||
| Equipped with a fluorescence meter mode, it can directly measure the fluorescence intensity of the sample | ||
| Including lon sphere mode | ||
| Including fluorescence standard curve module, allowing for free selection of excitation and emission light sources, curve type, standard volume, and total reagent volume | ||
| Including fluorescence kinetics module, customizable delay time, interval time, and detection frequency for up to 5 stages | ||
| Optional Function | Mixing in a colorimetric dish | The mixing speed can be adjusted to 10 levels, and the mixing time can be configured |
| Print function | Built in thermal printer | |
| Liquid column monitoring function | The equipment has a monitoring function for the sample liquid column, which can monitor whether there are bubbles or other abnormalities in the sample liquid column, ensuring the reliability of the detection | |
| Audit tracking function | Once the audit trail is enabled, it cannot be closed; Having hierarchical permission management, different user groups have different permissions; It can record and query user operation information. Meet users' requirements for electronic record traceability. | |
| External Size (W×D×H) | 200×300×200 mm | |
| Shipping Size (W×D×H) | 360×290×330 mm | |
| N.W/G.W. | 3.5/4.5 kg | |
Application:
The Microvolume UV-Vis Spectrophotometer is designed for the rapid and accurate quantification of microvolumes in genomics, proteomics, molecular biology, biotechnology, pharmaceuticals and life sciences research. The instrument also includes a built-in fluorescence module, capable of measuring fluorescence intensity, supporting Ion Sphere mode, and providing customizable options like excitation/emission light sources and fluorescence kinetics. Perfect for high-throughput labs and those requiring small sample volumes, it ensures accurate results with minimal sample waste.
Advantage:
1. Supports USB data output, can connect to Ethernet, Bluetooth and WI-FI
2. Output ports: Equipped with 2 USB-A interfaces, 1 Type C interface, 1 HDMI, and 1 Ethernet port, it can be used to connect with various devices such as mice, keyboards, desktop computers, etc
3. Spectral chart function with one click export of scan detection results
4. Fluorescence detection has a custom standard curve module, which can be more freely compatible with more reagent kits and experimental methods
5. Fluorescence detection has a kinetic module that can perform fluorescence kinetic detection and draw kinetic curves
6. The colloidal gold module has a unique automatic peak detection function, which can automatically search for the characteristic wavelengths of colloidal gold with different particle sizes
7. The standard curve has multiple fitting methods to meet diverse experimental needs
Specification:
| Model | SP-MUV5900I | |
| Performance Parameter | Light source | Longevity lifeline xenon flashing light (10⁹ times) |
| Detector | 2048 (coms) linear image sensor | |
| Detection wavelength range | 190–850 nm | |
| Xenon lamp photometric range | 185–2000 nm | |
| Wavelength accuracy | ±1 nm | |
| Wavelength resolution | 2 nm (FWHM at Hg 254 nm) | |
| Accuracy of absorbance | 1% (0.988 absorbance at 257 nm) | |
| Monitor | 10.1-inch touch screen, multi-point capacitive touch screen | |
| Detection time | Less than 3 seconds | |
| Optical path | Ultra trace mode 1, 0.4, 0.1, 0.04, 0.02 mm (optical path automatic conversion) | |
| Cuvette mode 10, 5, 2, 1 mm | ||
| Volume requirements | Ultra trace 0.3–2 μL | |
| Cuvette dish ≥ 1000 μL (10 mm optical path) | ||
| Range of absorbance | Ultra trace mode 0–800 Abs (equivalent to 10 mm optical path) | |
| Cuvette mode 0–16 Abs (equivalent to 10 mm optical path) | ||
| Concentration measurement range | Ultra trace: 2–40000 ng/μL (dsDNA) | |
| Cuvette (10 mm): 0.2–80 ng/μL (dsDNA) | ||
| Detecting repeatability | 0.002 A (1 mm optical path) or 1% CV | |
| Equipped with automatic measurement and zero adjustment functions, the detection arm can be lowered to achieve real-time detection; | ||
| Equipped with intelligent sample detection function, it provides information prompts and pollutant types upon discovering pollutants. The types of pollutants that can be identified include at least: protein, nucleic acid, phenol, guanidine isothiocyanate, and guanidine hydrochloride. And it has a result correction function, which can provide the original concentration of the sample, the corrected concentration, and the type of pollutant. Ensure the accurate concentration and quality of the sample, and guarantee the accuracy and best experimental results of the experiment | ||
| The nucleic acid testing module includes | dsDNA, SsDNA, RNA, User settings oligoDNA, oligoRNA , Gene chip module | |
| The protein detection module includes | A280, Peptide, protein chip, BCA, Bradford, Lowry, Pierce660 module | |
| The 0D600 module includes | Cell fluid module | |
| Custom modules include | Full wavelength, standard curve, colloidal gold, kinetic module | |
| The standard curve has multiple curve fitting functions | Linear, interpolation, second-order polynomial, third-order polynomial | |
| Can perform full wavelength colorimetric dish absorption light detection | ||
| Flexible dynamic module that can achieve dynamic detection in 5 stages, with customizable delay time, interval time, and detection frequency | ||
| Fluorescent Module | Excitation wavelength range | 190–1000 nm |
| Emission wavelength range | 280–850 nm | |
| Excitation filter | Standard configuration 355, 485, 544, 646 nm | |
| Emission filter | Standard configuration 460, 538, 590, 678 nm | |
| Detector | Photodiode (320–1100 nm) | |
| Sample flux | 1 piece | |
| Sample dosage | 1–20 μL | |
| Tube type | 0.5 mL PCR tube | |
| Tube sampling volume | ≥100 μL | |
| Warm-up time | No preheating required | |
| Measurement speed | 3s/tube | |
| Linear | R²≥0.995 | |
| Linear range | 5 orders of magnitude | |
| Built in reagent calculator to calculate the required amount of dye and buffer solution for the working solution | ||
| Equipped with a fluorescence meter mode, it can directly measure the fluorescence intensity of the sample | ||
| Including lon sphere mode | ||
| Including fluorescence standard curve module, allowing for free selection of excitation and emission light sources, curve type, standard volume, and total reagent volume | ||
| Including fluorescence kinetics module, customizable delay time, interval time, and detection frequency for up to 5 stages | ||
| Optional Function | Mixing in a colorimetric dish | The mixing speed can be adjusted to 10 levels, and the mixing time can be configured |
| Print function | Built in thermal printer | |
| Liquid column monitoring function | The equipment has a monitoring function for the sample liquid column, which can monitor whether there are bubbles or other abnormalities in the sample liquid column, ensuring the reliability of the detection | |
| Audit tracking function | Once the audit trail is enabled, it cannot be closed; Having hierarchical permission management, different user groups have different permissions; It can record and query user operation information. Meet users' requirements for electronic record traceability. | |
| External Size (W×D×H) | 200×300×200 mm | |
| Shipping Size (W×D×H) | 360×290×330 mm | |
| N.W/G.W. | 3.5/4.5 kg | |