GC-901 Gas Chromatograph

Model : GC-901

Oven Temp. Accuracy : ≤±0.01℃
Oven Temp. Program : 16-phase
Oven Time Range : 0-999.9min
Size(W×D×H)(mm) : 560x560x485
 
Availability:
Quantity:

Gas Chromatograph Specifications:

ModelGC-901
OvenTemp. RangeRT+5~450℃
Temp. Accuracy≤±0.01℃
Temp. Program16-phase
Max. Temp. Heating Rate40℃/min
Time Range0-999.9min
DetectorHydrogen Flame Ionization Detector (FID)Detection limit: ≤5×10-12g/s (100ng/ul n-hexadecane-isooctane solution)
Temperature 450℃
Compatible with packed and capillary columns
Baseline drift: ≤2x10-13A/30min
Baseline noise: 3×10-14A
Dynamic range: ≥107
Thermal Conductivity Detector (TCD)Sensitivity: >5000mv.ml/mg (50mg/ml toluene-benzene solution)
Temperature 400℃
Baseline drift: ≤0.1mV/30min
Baseline noise: 0.03mV
Dynamic range: ≥105(±10%)
Electron Capture Detector (ECD)Detection limit: ≤1×10-14g/ml (Sample: n-hexadecane δ-666)
Dynamic range: ≥104
Flame Photometric Detector (FPD)Detection limit: ≤5×10-12g/s (S of 10ng/uL methyl parathion-ethanol solution)
Detection limit: ≤4×10-12g/s (P of 10ng/uL methyl parathion-ethanol solution)
Dynamic range: ≥S 103
Dynamic range: ≥P 104
Temperature 350℃
Nitrogen and Phosphorus Detector (NPD)Detection limit: ≤1×10-12g/s (Azobenzene)
Detection limit: ≤1×10-12g/s (Marla sulfur phosphorous)
Dynamic range: ≥103
Injection MethodCapillary column split/splitless sampling (with diaphragm purging function), packed column sampling, valve sampling, gas/liquid automatic sampling system, etc.
Inlet1~4, up to 3 capillary column inlets
Injection TypePacked column injection, capillary column injection. (Flow setting range: 0~1000ml/min)
Control AccuracyPressure: 0.01KPa; Flow: 0.01ml/min
Maximum Split Ratio1:999
Pressure SensorAccuracy: <2% of full scale;
Repeatability: <± 0.05KPa;
Range: 0~0.6MPa
Flow SensorsAccuracy: < 5% of full scale;
Repeatability: 0.5K Pa (full scale);
Output offset (accuracy): ±5%
Sampling ValveCan be equipped with multiple imported automatic control valves, which can run automatically in sequence
Power SupplyAC220V±10%, 50/60Hz
Standard AccessoryFID detector, Chromatography workstation software, Capillary sampler
Optional AccessorySample injection system, TCD, ECD, FPD and NPD detector, Chromatographic column.
Sizes(W×D×H)(mm)560x560x485
Shipping Size (W×D×H)(mm)780x750x750
N.W./G.W. (kg)50/75

Application of Gas Chromatograph:

GC-901 gas chromatograph can realize full EPC electronic flow control, realize full computer control of the instrument, and can be equipped with a high-precision liquid automatic sampler. It can be widely used in many fields such as petroleum, chemical industry, environmental protection, food safety, disease control, education and scientific research, and can analyze the macro, micro and trace amounts of organic matter, inorganic matter and gas.

Gas Chromatograph Feature:

1. Color widescreen, unique design of touch keys

  • 7-inch industrial color LCD screen design, more complete display information, more reasonable interface operation

  • Two sets of operating systems in Chinese and English to meet different user needs

  • Adopting resistive touch screen, feel good, durable, double operation of screen and software to achieve seamless connection


2. Humanized software operating system

  • Adopting advanced 10/100M self-adaptive Ethernet communication interface, built-in IP protocol stack, easily form a local area network, realize long-distance transmission, remote control, and remote diagnosis.

  • Equipped with IBrainChrom workstation, which can support multiple chromatographs (253 sets) to work at the same time, realize data processing and reverse control.

  • Having complete audit trail, user rights management, electronic signature and other functions, so that data and documents meet GMP management requirements

  • The built-in Modbus/TCP server of IBrainChrom workstation can easily connect the analysis results to DCS (distributed control system)

  • 3 independent connection threads that can be connected to local, laboratory supervisors and authorities, allowing them to monitor the operation of the instrument and analyze the data in real time.


3. High-precision gas flow control system (EPC)

  • High-precision gas flow control, to ensure the accuracy of GC analysis, to ensure the efficiency of daily analysis, EPC control accuracy 0.01psi

  • It realizes the self-protection of gas circuit failure, automatic ignition, re-ignition, automatic opening of the gas circuit, and one-key start.

  • A variety of control combination modes of operation, automatic pressure and flow adjustment, control and display, can operate in gas-saving mode


4. Leading structural design

  • Modular structure design, easy to upgrade, can be equipped with a variety of high-performance detectors such as FID, TCD, ECD, FPD and NPD, etc., to meet the analysis needs of complex samples

  • Advanced sampler design, unique liner structure and special processing technology to ensure zero adsorption of samples

  • Adapting to a variety of sample injection methods such as: headspace sampler, thermal desorption analyzer, liquid automatic sampler, easily competent for the analysis of various sample types

  • Timed self-starting program can easily complete the laboratory online analysis of gas and liquid samples

Previous: 
Next: 
Get Quotation/Become Distributor

About Company​​​​​​​

As a professional lab and medical equipment manufacturer, Scitek Global is certified by ISO 9001, ISO 13485, ISO 45001 and ISO 14001. Almost all our products are certified by ETL, CE and FDA .

Scitek Global looks forward to establishing cooperation with more distributors all over the world, and working together to create greater customer value.

Quick Links

Contact Us
Scitek Global Co.,Ltd
  No. 7000 Jingshi Road, Jinan City, Shandong Province, China
/  +86-531-82893797
  Inquiry: info@scitekglobal.com
Service: 
service@scitekglobal.com
Complaints: 

complaints@scitekglobal.com
 
Scitek Global Inc.
9999 Bellaire Blvd Ste 505, Houston, TX 77036, United States
  +1 (915) 4126735
info@scitekglobal.net
 
Scitek Ethiopia
 tsion@scitekglobal.com
Copyright © 2023 Scitek Global Co., Ltd. All rights reserved.  Sitemap  Privacy Policy