Gas Chromatograph GC-901A

Model : GC-901A

Hydrogen Flame (FID) : ≤0.2mv
Thermal Conductivity Cell (TCD) : ≤20uv
Shipping Size(W×D×H)(mm) : 630x560x530
 
Availability:
Quantity:

Gas Chromatograph Specifications:

ModelGC-901A
DetectorSensitivity / Detection LimitDrift (30min)Linearity
Hydrogen Flame (FID)DFID≤3×10-12g/s (N-hexadecane / Isooctane)≤0.2mv>107
Thermal Conductivity Cell (TCD)S≥10000mv.ml/mg (Benzene/Toluene)≤20uv>105
Electron Capture (ECD)DECD≤1×10-14g/ml (γ-666)<15uv>106
Flame Luminosity (FPD)DFPD(S)≤2×10-11g/st (S in methyl parathion)≤ 3% of full scale>103
DFPD(P)≤1×10-12g/s (P in methyl parathion)>104
Nitrogen and Phosphorus
(NPD)
DNPD(N)≤1×10-12g/s (Azobenzene)≤ 3% of full scale>102
DNPD(P)≤1×10-12g/s (Malathion)>103
Power SupplyAC220V±10%, 50/60Hz
Shipping Size (W×D×H)(mm)630x560x530
N.W./G.W. (kg)48/68

Gas Chromatograph Feature:

  1. The inlet port adopts a new design, and the dual-column compensation function not only solves the baseline drift caused by programmed temperature rise but also reduces the influence of background noise to obtain a lower detection limit.

  2. The compact design of the vapor chamber makes the volume smaller;

  3. Replacement of accessories such as feed pads and nozzles can be done with one hand; the main parts, such as filled columns, TCD, FID detector, etc., can be disassembled entirely with only one plate hand, making maintenance very convenient.

  4. Intelligent rear door opens to control the air volume of import and export, shortening the equilibrium time for system stability after programmed temperature rise/reduction.

  5. Up to 4 types of injection ports can be installed: packed column, capillary column, and shunt/non-shunt injection systems are available.

  6. The gas chromatograph has a 4.3-inch color LCD touchscreen and keyboard input for user-friendly operation.

  7. Adopt primary pressure regulator valve and flow regulator/pressure regulator valve double stable gas circuit design.

  8. Temperature control device to ensure that the temperature control accuracy is less than ± 0.1 ℃.

  9. Double over-temperature protection and power failure protection function

  10. Fault self-test and alarm function to ensure stable operation of the machine.


Previous: 
Next: 
Get Quotation/Become Distributor

About Company​​​​​​​

As a professional lab and medical equipment manufacturer, Scitek Global is certified by ISO 9001, ISO 13485, ISO 45001 and ISO 14001. Almost all our products are certified by ETL, CE and FDA .

Scitek Global looks forward to establishing cooperation with more distributors all over the world, and working together to create greater customer value.

Quick Links

Contact Us
Scitek Global Co.,Ltd
  No. 7000 Jingshi Road, Jinan City, Shandong Province, China
/  +86-531-82893797
  Inquiry: info@scitekglobal.com
Service: 
service@scitekglobal.com
Complaints: 

complaints@scitekglobal.com
 
Scitek Global Inc.
9999 Bellaire Blvd Ste 505, Houston, TX 77036, United States
  +1 (915) 4126735
info@scitekglobal.net
 
Scitek Ethiopia
 tsion@scitekglobal.com
Copyright © 2023 Scitek Global Co., Ltd. All rights reserved.  Sitemap  Privacy Policy