Availability: | |
---|---|
Quantity: | |
7-inch color touch screen
Direct reading of concentration
Flameout protection device
Automatic calculation of correlation coefficients
Supports cloud connectivity, PC connection and printing
Model | SP-FPI6450 | SP-FPI6440 | SP-FP6432 | SP-FPI6431 | SP-FPI6430 | SP-FPI6410 | SP-FP6400 | |
---|---|---|---|---|---|---|---|---|
Display | 7-inch color touch screen | |||||||
Display Results | Concentration value/Energy | |||||||
Reading Range | 0.000-9999/0-65535 | |||||||
Testable | K, Na, Li, Ca, Ba | K, Na, Li, Ca | K, Na, Ba | K, Na, Ca | K, Na, Li | K, Na | K, Na | |
Channel Qty | 5 | 4 | 3 | 3 | 3 | 2 | 2 | |
Range (ppm) | K | 0-200 | 0-200 | 0-200 | 0-200 | 0-200 | 0-200 | 0-200 |
Na | 0-200 | 0-200 | 0-200 | 0-200 | 0-200 | 0-200 | 0-200 | |
Li | 0-200 | 0-200 | / | / | 0-200 | / | / | |
Ca | 0-1000 | 0-1000 | / | 0-1000 | / | / | / | |
Ba | 0-3000 | / | 0-3000 | / | / | / | / | |
Detection Limit (ppm) | K | ≤0.16 | ||||||
Na | ≤0.18 | |||||||
Li | ≤0.105 | ≤0.105 | / | / | ≤0.105 | / | / | |
Ca | ≤2 | ≤2 | / | ≤2 | / | / | / | |
Ba | ≤0.6 | / | ≤0.6 | / | / | / | / | |
Linear Error | K | ≤0.2 | ||||||
Na | ≤0.7 | |||||||
Li | ≤0.147 | ≤0.147 | / | / | ≤0.147 | / | / | |
Ca | ≤3 | ≤3 | / | ≤3 | / | / | / | |
Ba | ≤9 | / | ≤9 | / | / | / | / | |
Response Time | <8s | |||||||
Sample Uptake | <6ml/min | |||||||
Stability | <3% drift over 15s when continuous sampling | |||||||
Reproducibility | <3% coefficient of variation for 7 consecutive samples | |||||||
Curve Graph | Yes | Yes | Yes | Yes | Yes | No | No | |
Bluetooth Printer | Yes | Optional | ||||||
Output | USB port | |||||||
Standard Accessory | Air compressor | |||||||
Power Supply | AC 220/110V, 50/60Hz | |||||||
External Size (WxDxH)(mm) | 480x260x330 | |||||||
Shipping Size (WxDxH)(mm) | 710x380x515 | |||||||
N.W./G.W.(kg) | 16/20 |
7-inch color touch screen
Direct reading of concentration
Flameout protection device
Automatic calculation of correlation coefficients
Supports cloud connectivity, PC connection and printing
Model | SP-FPI6450 | SP-FPI6440 | SP-FP6432 | SP-FPI6431 | SP-FPI6430 | SP-FPI6410 | SP-FP6400 | |
---|---|---|---|---|---|---|---|---|
Display | 7-inch color touch screen | |||||||
Display Results | Concentration value/Energy | |||||||
Reading Range | 0.000-9999/0-65535 | |||||||
Testable | K, Na, Li, Ca, Ba | K, Na, Li, Ca | K, Na, Ba | K, Na, Ca | K, Na, Li | K, Na | K, Na | |
Channel Qty | 5 | 4 | 3 | 3 | 3 | 2 | 2 | |
Range (ppm) | K | 0-200 | 0-200 | 0-200 | 0-200 | 0-200 | 0-200 | 0-200 |
Na | 0-200 | 0-200 | 0-200 | 0-200 | 0-200 | 0-200 | 0-200 | |
Li | 0-200 | 0-200 | / | / | 0-200 | / | / | |
Ca | 0-1000 | 0-1000 | / | 0-1000 | / | / | / | |
Ba | 0-3000 | / | 0-3000 | / | / | / | / | |
Detection Limit (ppm) | K | ≤0.16 | ||||||
Na | ≤0.18 | |||||||
Li | ≤0.105 | ≤0.105 | / | / | ≤0.105 | / | / | |
Ca | ≤2 | ≤2 | / | ≤2 | / | / | / | |
Ba | ≤0.6 | / | ≤0.6 | / | / | / | / | |
Linear Error | K | ≤0.2 | ||||||
Na | ≤0.7 | |||||||
Li | ≤0.147 | ≤0.147 | / | / | ≤0.147 | / | / | |
Ca | ≤3 | ≤3 | / | ≤3 | / | / | / | |
Ba | ≤9 | / | ≤9 | / | / | / | / | |
Response Time | <8s | |||||||
Sample Uptake | <6ml/min | |||||||
Stability | <3% drift over 15s when continuous sampling | |||||||
Reproducibility | <3% coefficient of variation for 7 consecutive samples | |||||||
Curve Graph | Yes | Yes | Yes | Yes | Yes | No | No | |
Bluetooth Printer | Yes | Optional | ||||||
Output | USB port | |||||||
Standard Accessory | Air compressor | |||||||
Power Supply | AC 220/110V, 50/60Hz | |||||||
External Size (WxDxH)(mm) | 480x260x330 | |||||||
Shipping Size (WxDxH)(mm) | 710x380x515 | |||||||
N.W./G.W.(kg) | 16/20 |