You are here: Home » Products » Clinical Analyzers and Reagents » Blood Gas and Electrolyte Analyzer » Blood Gas Analyzer, Automatic Calibration

Blood Gas Analyzer, Automatic Calibration

Model : BGE-95I
 
Test Items : pH, pCO2, pO2, Hct
Analysis Time : <90s
Sizes(W×D×H)(mm) : 400x574x344
 
Availability:
Quantity:

How to Instruction of Blood Gas Analyzer:

Blood Gas and Electrolyte Analyzer Specification:

Model BGE-95I
Analyte Measuring range Unit
Hydrogen Ion Activity(pH) 6.000―9.000 pH scale
Carbon Dioxide 0.667―26.67 kPa
partial Pressure(pO2) 5.0―200.0 mmHg
Oxygen Partial Pressure (pCO2) 0―106.7 kPa
0―800.0 mmHg
Hct 12.0―65.0 %
B.P. 500―800 mmHg
Derived(Calculated) Parameters:
pH(TC) pH temperature corrected
pCO2 (TC) pCO2 temperature corrected
pO2 (TC) pO2 temperature corrected
TCO2 0-50mmol/L
HCO3 0-50mmol/L
Beb -25.0-25mmol/L
Beecf -25.0-25mmol/L
SBC 0-50mmol/L
SO2 40-100.0%
RI 0.0-70.0
AaDO2 0-700mmHg
O2SAT Oxygen Saturation
tHb(c) Hemoglobin(Calculated)
Sample Whole blood, Serum, Plasma, Dialysate, CSF
Test Items pH, pCO2, pO2, Hct
Input Parameter Patient temperature
Hemoglobin
FiO
Interface Serial Line RS-232
TCP/IP interface
USB port
Integrated Bar-code reader
Analysis Time <90s
Sample Volume 95μL Whole blood
50μL Capillary blood
Calibration Automatic, programmable1-point and 2-point calibration
Data Storage >10000
Display 10.4” TFT touch screen
Battery Nickel-metal hydride battery 3.0Ah
Printer Build-in Thermal printer70mm
Barcode Reader Up to 14 kinds barcode type
Work Environment 15℃~30℃
Storage Environment 5℃~40℃
Power Supply 100-240V~50/60Hz
CAL PAK 258x180x70
AUTOQC 103x180x70
Sizes(W×D×H)(mm) 400x574x344
Shipping Size(W×D×H)(mm) 940x670x620
N.W./G.W. (kg) 30/60

Blood Gas and Electrolyte Analyzer Features:

The BGE-95I is an easy-to-use portable blood gas analyzer that provides accurate blood gas, electrolyte and critical care biochemistry results and is widely used in the healthcare industry.

  1. Multiple combinations can test multiple parameters  at once

  2. Maintenance-free electrodes, saving maintenance cost and time

  3. Capillary 50 UL, whole blood 95 UL, suitable for syringes and capillaries

  4. Fast detection time can produce results in a short period

  5. Automatic alarm in case of malfunction

  6. Data storage >10,000 items, you can easily view the monitoring data

  7. High-resolution color touch screen, user-friendly operation interface

  8. Built-in thermal printer for real-time printing of test data

  9. Equipped with a battery backup, even if the power outage can work normally

FAQ

What types of samples can the Blood Gas and Electrolyte Analyzer test?

It is suitable for whole blood samples, including arterial blood, venous blood, and capillary blood. Specific sample types and volume requirements vary depending on the instrument model and configuration; please refer to the device’s operating manual for guidance.

How long does the test take?

Most blood gas and electrolyte analyzers can produce results within minutes, meeting the need for rapid diagnosis in emergency departments, intensive care units (ICUs), operating rooms, and clinical laboratories, and supporting immediate clinical decision-making.

What is the clinical significance of blood gas and electrolyte testing?

This test helps clinicians assess a patient’s respiratory function, metabolic status, electrolyte balance, and tissue oxygenation, making it an indispensable laboratory tool in critical care and emergency medicine.

Is this Blood Gas and Electrolyte Analyzer suitable for point-of-care testing (POCT)?

Yes. Blood gas and electrolyte analyzers are typically compact, provide rapid results, and are easy to operate, making them ideal for point-of-care testing in clinical departments. This reduces sample turnaround time and improves diagnostic and treatment efficiency.

What routine maintenance does a Blood Gas and Electrolyte Analyzer require?

Routine maintenance typically includes electrode calibration, reagent replacement, tubing cleaning, and quality control verification. Modern analyzers often feature automated maintenance functions, which can effectively reduce the workload on operators.

How should one select a suitable blood gas and electrolyte analyzer?

When selecting a model, the following factors should be comprehensively considered: range of test parameters, sample processing capacity, testing speed, level of automation, ability to integrate with information systems, maintenance costs, and actual clinical needs. Choose a configuration that matches the scale of your hospital’s clinical services and the specific requirements of your department.


Previous: 
Next: 
Get Quotation/Become Distributor

About Company​​​​​​​

As a professional lab and medical equipment manufacturer, Scitek Global is certified by ISO 9001, ISO 13485, ISO 45001 and ISO 14001. Almost all our products are certified by ETL, CE and FDA .

Scitek Global looks forward to establishing cooperation with more distributors all over the world, and working together to create greater customer value.

Quick Links

Contact Us
Scitek Global Co.,Ltd
  No. 7000 Jingshi Road, Jinan City, Shandong Province, China
/  +86-531-82893797
  Inquiry: info@scitekglobal.com
 
Scitek Global Inc.
9999 Bellaire Blvd Ste 505, Houston, TX 77036, United States
  +1 (915) 4126735
info@scitekglobal.net
 