| Availability: | |
|---|---|
| Quantity: | |
In accordance with Archimedes principle water buoyancy method, GB/T1423 of precious metals testing standard, and so on.
The high-precision gold purity tester will not damage the sample, can quickly, easily, and accurately distinguish and test the K value of gold, the PT value of platinum, the purity percentage of other precious metals, and their density. It is suitable for the jewelry shop,pawn broking, bank, precious-metals recovery, jewelry factory, Gemstone Testing Center, precious metals researching laboratories.etc. It can measure precious metals such as gold, karat gold, platinum, platinum, and silver.
1. Quickly test the purity of gold, platinum, and other precious metals, distinguish fakes.
2. Non-destructive testing, clean and environmentally friendly, with no damage to the original sample.
3. Fast and convenient testing, just need 10 seconds, stable and accurate.
4. Multi-mode: freely switch between gold, platinum, and other precious metal modes.
5. Multi-function: it can measure the purity of other precious metals, such as tin, copper, and silver, can also be used as a precision balance.
6. With upper and lower limit functions:it displays OK, HI, LO based on the status of qualified, exceed,less with an alarm.
7. Cannot measure hollow samples or samples inlaid with gemstones.
8. With fully automatic zero tracking, buzzer alarm, and overload alarm functions.
9. Uses water as the medium, other liquids are also acceptable. The actual water temperature can be set.
10. Compared to traditional drop-in-water methods, this unit utilizes a single-piece, large-capacity measuring instrument. The water tank is corrosion-resistant, drop-resistant, and break-resistant, and the hanging wire will not affect the measurement results.
11. Standard with RS-232 output port.
12. Printer is optional,can print the testing result directly.
13. Standard with dedicated windproof and dust-proof cover,easy assembly.
14. High-precision, suitable for small samples and demanding applications.
| Model | DME-120PM | DME-200PM | DME-300PM | DME-600PM | DME-900PM | DME-1200PM | DME-2000PM | DME-3000PM | |
| Capacity (g) | 120 | 200 | 300 | 600 | 900 | 1200 | 2000 | 3000 | |
| Display | LCD display | ||||||||
| Weight Resolution (g) | 0.001 | 0.001 | 0.005 (0.01 g optional) | 0.005 | 0.01 | 0.01 | 0.01 | 0.01 | |
| Necessary Weight for Density (g) | 2 | 2 | 4 | 4 | 5 | 5 | 5 | 5 | |
| Density Resolution | 0.001 g/cm3 | ||||||||
| Measuring Time | 10 S | ||||||||
| Testing Board | Completed high-capacity plastic testing board | ||||||||
| Measuring Type | Traditional gold and platinum jewelry, necklace, bracelet, ring, large bullion, craft, and gold, silver, copper, cadmium, nickel, tin. etc. | ||||||||
| Gold Mode | Display K Value | The K value of mixture of gold, silver, and copper | |||||||
| The K value of mixture of gold and copper | |||||||||
| The K value of mixture of gold and silver | |||||||||
Display Purity Percent | The purity percentage of mixture of gold, silver and copper | ||||||||
| The purity percentage of mixture of gold and copper | |||||||||
| The purity percentage of mixture of gold and silver | |||||||||
| K Value Range | 10~24 K | ||||||||
Copper and Silver Proportion Setting | Cycle seting (default 7:3) | ||||||||
| Testing Error | Default as ±1K; also can be set up as 0.1 K, 0.01 K, need to confirm with factory firstly | ||||||||
| Platinum | Display Value | PT percent, density value, volume | |||||||
| Mode | PT Value Range | Pt600 - Pt1000 | |||||||
| Other Precious Metals | Function | Only for DME-120PM and DME-200PM: measure the purity percentage of main materials in two kinds of mixture | |||||||
| Display Value | Only for DME-120PM and DME-200PM: density value, volume, content percentage | ||||||||
| setting | Only for DME-120PM and DME-200PM: density value of main materials and secondary materials setting | ||||||||
| Measuring Container | Completed injection forming transparent professional measuring tank (size (L×W×H): 169×98×83 mm) | ||||||||
| Parameter Setting | Water temperature setting, measuring medium density setting | ||||||||
| Principle | Archimedes principle | ||||||||
| Memory Method | Two procedures | ||||||||
| Correction Method | Auto calibration with one key, auto detection. | ||||||||
| Output Method | Output and print testing data conveniently with standard communication interface of RS-232C. | ||||||||
| Standard Accessories | Host, tank, test board, tweezer, thermometer, weight, wind and dust cover, a set of measuring particle parts, a set of measuring floating body parts, power transformer | ||||||||
| Wind and Dust Cover | Adopt the unicase dedicated wind and dust cover | ||||||||
| Option Accessories | Printer | ||||||||
| Power | Default as AC 100 V–240 V (Europe standard),based on destination country which standards be took. | ||||||||
| Main Features | Simple operation, digital display, accurate measuring, stable, durable. | ||||||||
| External Size (W×D×H) | 195×230×197 mm | ||||||||
| Shipping Size (W×D×H) | 440×180×345 mm | ||||||||
| N.W./G.W. (kg) | 1.6 / 4.5 | 1.8 / 4.5 | 1.8 / 5 | 1.9 / 5.5 | |||||
In accordance with Archimedes principle water buoyancy method, GB/T1423 of precious metals testing standard, and so on.
The high-precision gold purity tester will not damage the sample, can quickly, easily, and accurately distinguish and test the K value of gold, the PT value of platinum, the purity percentage of other precious metals, and their density. It is suitable for the jewelry shop,pawn broking, bank, precious-metals recovery, jewelry factory, Gemstone Testing Center, precious metals researching laboratories.etc. It can measure precious metals such as gold, karat gold, platinum, platinum, and silver.
1. Quickly test the purity of gold, platinum, and other precious metals, distinguish fakes.
2. Non-destructive testing, clean and environmentally friendly, with no damage to the original sample.
3. Fast and convenient testing, just need 10 seconds, stable and accurate.
4. Multi-mode: freely switch between gold, platinum, and other precious metal modes.
5. Multi-function: it can measure the purity of other precious metals, such as tin, copper, and silver, can also be used as a precision balance.
6. With upper and lower limit functions:it displays OK, HI, LO based on the status of qualified, exceed,less with an alarm.
7. Cannot measure hollow samples or samples inlaid with gemstones.
8. With fully automatic zero tracking, buzzer alarm, and overload alarm functions.
9. Uses water as the medium, other liquids are also acceptable. The actual water temperature can be set.
10. Compared to traditional drop-in-water methods, this unit utilizes a single-piece, large-capacity measuring instrument. The water tank is corrosion-resistant, drop-resistant, and break-resistant, and the hanging wire will not affect the measurement results.
11. Standard with RS-232 output port.
12. Printer is optional,can print the testing result directly.
13. Standard with dedicated windproof and dust-proof cover,easy assembly.
14. High-precision, suitable for small samples and demanding applications.
| Model | DME-120PM | DME-200PM | DME-300PM | DME-600PM | DME-900PM | DME-1200PM | DME-2000PM | DME-3000PM | |
| Capacity (g) | 120 | 200 | 300 | 600 | 900 | 1200 | 2000 | 3000 | |
| Display | LCD display | ||||||||
| Weight Resolution (g) | 0.001 | 0.001 | 0.005 (0.01 g optional) | 0.005 | 0.01 | 0.01 | 0.01 | 0.01 | |
| Necessary Weight for Density (g) | 2 | 2 | 4 | 4 | 5 | 5 | 5 | 5 | |
| Density Resolution | 0.001 g/cm3 | ||||||||
| Measuring Time | 10 S | ||||||||
| Testing Board | Completed high-capacity plastic testing board | ||||||||
| Measuring Type | Traditional gold and platinum jewelry, necklace, bracelet, ring, large bullion, craft, and gold, silver, copper, cadmium, nickel, tin. etc. | ||||||||
| Gold Mode | Display K Value | The K value of mixture of gold, silver, and copper | |||||||
| The K value of mixture of gold and copper | |||||||||
| The K value of mixture of gold and silver | |||||||||
Display Purity Percent | The purity percentage of mixture of gold, silver and copper | ||||||||
| The purity percentage of mixture of gold and copper | |||||||||
| The purity percentage of mixture of gold and silver | |||||||||
| K Value Range | 10~24 K | ||||||||
Copper and Silver Proportion Setting | Cycle seting (default 7:3) | ||||||||
| Testing Error | Default as ±1K; also can be set up as 0.1 K, 0.01 K, need to confirm with factory firstly | ||||||||
| Platinum | Display Value | PT percent, density value, volume | |||||||
| Mode | PT Value Range | Pt600 - Pt1000 | |||||||
| Other Precious Metals | Function | Only for DME-120PM and DME-200PM: measure the purity percentage of main materials in two kinds of mixture | |||||||
| Display Value | Only for DME-120PM and DME-200PM: density value, volume, content percentage | ||||||||
| setting | Only for DME-120PM and DME-200PM: density value of main materials and secondary materials setting | ||||||||
| Measuring Container | Completed injection forming transparent professional measuring tank (size (L×W×H): 169×98×83 mm) | ||||||||
| Parameter Setting | Water temperature setting, measuring medium density setting | ||||||||
| Principle | Archimedes principle | ||||||||
| Memory Method | Two procedures | ||||||||
| Correction Method | Auto calibration with one key, auto detection. | ||||||||
| Output Method | Output and print testing data conveniently with standard communication interface of RS-232C. | ||||||||
| Standard Accessories | Host, tank, test board, tweezer, thermometer, weight, wind and dust cover, a set of measuring particle parts, a set of measuring floating body parts, power transformer | ||||||||
| Wind and Dust Cover | Adopt the unicase dedicated wind and dust cover | ||||||||
| Option Accessories | Printer | ||||||||
| Power | Default as AC 100 V–240 V (Europe standard),based on destination country which standards be took. | ||||||||
| Main Features | Simple operation, digital display, accurate measuring, stable, durable. | ||||||||
| External Size (W×D×H) | 195×230×197 mm | ||||||||
| Shipping Size (W×D×H) | 440×180×345 mm | ||||||||
| N.W./G.W. (kg) | 1.6 / 4.5 | 1.8 / 4.5 | 1.8 / 5 | 1.9 / 5.5 | |||||