Availability: | |
---|---|
Quantity: | |
Model | ION-B600 | |
---|---|---|
Parameters | pH/ISE/Temp.(mV/ORP/pX) | |
pH | Range | -2.000 to 20.000 pH |
Resolution | 0.1, 0.01, 0.001pH | |
Accuracy | ±0.002 pH | |
Calibration Points | Up to 6 | |
Standard Customization | Yes | |
Calibration Reminder | Yes | |
Standard Recognition | NIST, GB, DIN buffers | |
Slope Limit | Yes | |
mV/ORP | Range | -2000.00 to 2000.00 mV |
Resolution | 0.1, 0.01 mV | |
Accuracy | ±0.1 mV or ±0.03% | |
EH ORP Mode | Yes | |
ORP Calibration Points | 1~2 custom point (relative mV) | |
pX | Range | -2.000 to 20.000 pX |
Resolution | 0.1, 0.01, 0.001 pX | |
Accuracy | ±0.002 pX | |
Calibration Points | Up to 6 | |
ISE | Range | 0~19990 |
Units | mol/L, mmol/L, g/L, mg/L, μg/L | |
Resolution | Up to 4 significant digits | |
Accuracy | ±0.3% | |
Calibration Points | Up to 6 | |
Temperature | Range | -5 to 130 ºC |
Unit | ºC | |
Resolution | 0.1 | |
Accuracy | ±0.1 | |
Measurement | Reading Mode | Auto Read (Fast, Medium, Slow), Timed, Continuous |
Reading Prompts | Reading, Stable, Locked | |
Temp. Compensation | ATC, MTC | |
Data management | Data Storage | 1000 Groups |
GLP Features | Yes | |
Log Management | Yes | |
Inputs | pH Electrode | BNC(Q9) |
Temp. Probe | 6-pin Mini-DIN | |
Outputs | USB, RS 232 | USB 2.0 flash memory device, printer, PC |
Display options | Backlight | Yes |
Auto Shutdown | 1~60 min, off | |
IP Rating | IP54 | |
Date and Time | Yes | |
General | Electricity | AC Adapter, 100-240V AC input, DC24V output |
Sizes(W×D×H) | 280×280×130 | |
Shipping size (W×D×H)(mm) | 370×305×330 | |
N.W./G.W. (kg) | 2.5/4.5 |
The benchtop ion meter accurately measures the concentration of N+ ions, including ammonium, bromine, cadmium, calcium, chlorine, copper, cyanide, fluoride, and lead. Measurements are accurate to 0.3% F.S., making it ideal for precision experiments.
Precision laboratory ion meter with large backlit LCD.
Up to 6 point calibration, including 10 concentration calibration points.
Direct reading of ion concentration values, eliminating tedious conversions and calculations.
Choose from ppm, mg/L and mol/L units.
Automatic temperature compensation ensures accurate measurements over the full range.
Automatic endpoint lockout keeps stable readings for easy viewing and recording.
Calibration due reminder, prompting the user to calibrate the meter regularly.
Automatic electrode diagnostics with calibration point and slope display.
Setup menu with customizable settings for multiple functions
Reset function automatically restores the meter to factory default settings.
Large memory, can store 500 sets of data.
USB interface, easy to transfer data
Model | ION-B600 | |
---|---|---|
Parameters | pH/ISE/Temp.(mV/ORP/pX) | |
pH | Range | -2.000 to 20.000 pH |
Resolution | 0.1, 0.01, 0.001pH | |
Accuracy | ±0.002 pH | |
Calibration Points | Up to 6 | |
Standard Customization | Yes | |
Calibration Reminder | Yes | |
Standard Recognition | NIST, GB, DIN buffers | |
Slope Limit | Yes | |
mV/ORP | Range | -2000.00 to 2000.00 mV |
Resolution | 0.1, 0.01 mV | |
Accuracy | ±0.1 mV or ±0.03% | |
EH ORP Mode | Yes | |
ORP Calibration Points | 1~2 custom point (relative mV) | |
pX | Range | -2.000 to 20.000 pX |
Resolution | 0.1, 0.01, 0.001 pX | |
Accuracy | ±0.002 pX | |
Calibration Points | Up to 6 | |
ISE | Range | 0~19990 |
Units | mol/L, mmol/L, g/L, mg/L, μg/L | |
Resolution | Up to 4 significant digits | |
Accuracy | ±0.3% | |
Calibration Points | Up to 6 | |
Temperature | Range | -5 to 130 ºC |
Unit | ºC | |
Resolution | 0.1 | |
Accuracy | ±0.1 | |
Measurement | Reading Mode | Auto Read (Fast, Medium, Slow), Timed, Continuous |
Reading Prompts | Reading, Stable, Locked | |
Temp. Compensation | ATC, MTC | |
Data management | Data Storage | 1000 Groups |
GLP Features | Yes | |
Log Management | Yes | |
Inputs | pH Electrode | BNC(Q9) |
Temp. Probe | 6-pin Mini-DIN | |
Outputs | USB, RS 232 | USB 2.0 flash memory device, printer, PC |
Display options | Backlight | Yes |
Auto Shutdown | 1~60 min, off | |
IP Rating | IP54 | |
Date and Time | Yes | |
General | Electricity | AC Adapter, 100-240V AC input, DC24V output |
Sizes(W×D×H) | 280×280×130 | |
Shipping size (W×D×H)(mm) | 370×305×330 | |
N.W./G.W. (kg) | 2.5/4.5 |
The benchtop ion meter accurately measures the concentration of N+ ions, including ammonium, bromine, cadmium, calcium, chlorine, copper, cyanide, fluoride, and lead. Measurements are accurate to 0.3% F.S., making it ideal for precision experiments.
Precision laboratory ion meter with large backlit LCD.
Up to 6 point calibration, including 10 concentration calibration points.
Direct reading of ion concentration values, eliminating tedious conversions and calculations.
Choose from ppm, mg/L and mol/L units.
Automatic temperature compensation ensures accurate measurements over the full range.
Automatic endpoint lockout keeps stable readings for easy viewing and recording.
Calibration due reminder, prompting the user to calibrate the meter regularly.
Automatic electrode diagnostics with calibration point and slope display.
Setup menu with customizable settings for multiple functions
Reset function automatically restores the meter to factory default settings.
Large memory, can store 500 sets of data.
USB interface, easy to transfer data