| Availability: | |
|---|---|
| Quantity: | |
This automatic chemiluminescence gel imaging systems is a commonly used device for detecting and analysing chemiluminescence signals generated in gel electrophoresis experiments. Such systems are commonly used to detect the distribution and quantitative analysis of biomolecules such as proteins and nucleic acids on gels.
| Model | ACG-I600 | ACG-I600M | 
|---|---|---|
| Pixel | 9.0MP | |
| Multi-color Fluorescent Function | No | Yes | 
| Cooling Temperature | -65°C | |
| Photosensitive Efficiency | High QE: >75% | |
| Pixel Size | 4.54μm×4.54μm | |
| Binning | 1×1 2×2 4×4··· 8×8 | |
| Exposure | 1ms-120min | |
| Bit | 16 bit (0-65535) | |
| OD | ≥4.8OD | |
| Lens | F = 0.95, 25mm, optionaF= 0.8, 25mm | |
| UV Transmission | 302nm, Area: 21x21cm | |
| Lighting | LED | |
| UV Reflection | No | |
| Filter Whee | Optional 2,5 position filter wheel | |
| Filter | Optional 590nm, other options | |
| Imaging Area | 20x20cm | |
| APP Timer Shut Down | 1 ~ 60min | |
| Sizes(W×D×H)(mm) | 405x380x695 | |
| Shipping Size (W×D×H)(mm) | 530x500x830 | |
| N.W./G.W. (kg) | 36/40 | 37/42 | 
Fully automatic control of the lens and lightsource.
Precise automatic exposure in calculate, noneed to repeat calculation the exposure time.
One button shooting, marker and chemiluminescence image automatic stacking.
Cryogenic scientific research ultrasensitiveCCD camera, wide aperture Lens.
This automatic chemiluminescence gel imaging systems is a commonly used device for detecting and analysing chemiluminescence signals generated in gel electrophoresis experiments. Such systems are commonly used to detect the distribution and quantitative analysis of biomolecules such as proteins and nucleic acids on gels.
| Model | ACG-I600 | ACG-I600M | 
|---|---|---|
| Pixel | 9.0MP | |
| Multi-color Fluorescent Function | No | Yes | 
| Cooling Temperature | -65°C | |
| Photosensitive Efficiency | High QE: >75% | |
| Pixel Size | 4.54μm×4.54μm | |
| Binning | 1×1 2×2 4×4··· 8×8 | |
| Exposure | 1ms-120min | |
| Bit | 16 bit (0-65535) | |
| OD | ≥4.8OD | |
| Lens | F = 0.95, 25mm, optionaF= 0.8, 25mm | |
| UV Transmission | 302nm, Area: 21x21cm | |
| Lighting | LED | |
| UV Reflection | No | |
| Filter Whee | Optional 2,5 position filter wheel | |
| Filter | Optional 590nm, other options | |
| Imaging Area | 20x20cm | |
| APP Timer Shut Down | 1 ~ 60min | |
| Sizes(W×D×H)(mm) | 405x380x695 | |
| Shipping Size (W×D×H)(mm) | 530x500x830 | |
| N.W./G.W. (kg) | 36/40 | 37/42 | 
Fully automatic control of the lens and lightsource.
Precise automatic exposure in calculate, noneed to repeat calculation the exposure time.
One button shooting, marker and chemiluminescence image automatic stacking.
Cryogenic scientific research ultrasensitiveCCD camera, wide aperture Lens.