You are here: Home » Products » Spectrophotometer and Colorimeter » Atomic Absorption Spectrophotometer » Atomic Absorption Spectrophotometer (Flame Method)

loading

Share to:
facebook sharing button
twitter sharing button
whatsapp sharing button
linkedin sharing button
pinterest sharing button
wechat sharing button
line sharing button
sharethis sharing button

Atomic Absorption Spectrophotometer (Flame Method)

Model : SP-AA3604F; SP-AA3608F

Optical System : Single Beam
Monochromator : Czerny-Turner type, focal lengths at 350mm
Wavelength Range (nm) : 185-900nm
Wavelength Accuracy(nm) : 0.3 nm; 0.2nm
Wavelength Repeatability (nm) : ≤0.1nm
External Size(WxDxH)(mm) : 830x650x560
Essential instruments for environmental monitoring, food testing, drug analysis and geological research.
Availability:
Quantity:

Atomic Absorption Spectrophotometer is widely used in the analysis of major and trace elements in metallurgy, geology, mining, petroleum, light industry, agriculture, medicine, health, food and environmental monitoring.

Atomic Absorption Spectrophotometer Features:

  1. Full titanium burner, stable combustion and fast heat balance.

  2. Excellent full-band deuterium lamp background correction technology.

  3. Simple, professional, automatic and comprehensive RG-WinAAS workstation software

  4. Excellent total reflection optical system ensures excellent signal-to-noise ratio of the instrument

  5. Comprehensive and safe smart gas control module.

  6. Fully automatic instrument control, the light source supports high-performance element lamps, and can be quickly completed with one click

  7. Novelly designed atomizer and intelligent lifting.

Atomic Absorption Spectrophotometer Specifications:

Model SP-AA3604F SP-AA3608F
Optical System Optical System Single Beam
Monochromator Czerny-Turner type, focal lengths at 350mm
Grating Grating 1800 lines/mm, scintillation wavelength 250nm
Spectral Bandwidth (nm) 0.1, 0.2, 0.4, 0.7, 1.4, 2nm Automated slit selection
Wavelength Range (nm) 185-900nm
Wavelength Accuracy(nm)
0.3 nm

0.2nm
Wavelength Repeatability (nm) ≤0.1nm
Spectral Bandwidth Deviation ±0.02 nm
Lamp Stand
4

8
Element Lamp Type Cu lamp(Standard accessory)
Other element lamp is optional accessory
Photometric Performance Reading Mode Transmittance, absorbance, concentration
Photometric Range 0-125%,-0.1-3.00A
Static Baseline Drift (Cu) ±0.004A/30min
±0.003A/30min
Dynamic Baseline Drift (Cu) ±0.006A/15min ±0.005A/15min
Background Correction Deuterium lamp≥ 40x (1Abs) Deuterium lamp≥ 40x (1Abs), self-priming≥ 80x (1Abs) (optional)
Flame System Characteristic Concentration (Cu) ≤0.04ug/ml
≤0.035ug/ml
Detection Limit (Cu) ≤0.008ug/ml ≤0.006ug/ml
Repeatability (Cu) RSD≤1% RSD≤0.6%
Acetylene Flow Control Auto 12-Level
Air Assist Control Auto 4-Level
Burner lift Automatic lifting
Burner Head Titanium 100mm burner
Nebulizer High efficiency glass nebulizer
Spray Chamber Corrosion-resistant material spray chamber
Safety Protection Automatically cut off gas in case of low pressure, power failure, flame out, or burner mismatched
Data Processing Measuring Method Flame method, Hydride generation-Atomic absorption method, Flame emission method
Concentration Calculation Method Standard curve method (6 linear/non-linear fitting methods), Standard addition method, Interpolation method
Repeat Measurement Times 1-30 times. Calculate and give the average value of absorbance/concentration. standard deviation and relative standard deviation
Report Printing Parameter printing, Data result printing
Other Computer External connect
Ambient Temp 10℃-30℃
Ambient Humidity 40%-85%
Power Supply 220/110V, 50/60HZ
External Size (WxDxH)(mm) 830x650x560
Shipping Size (WxDxH)(mm) 1000x780x810
N.W./G.W. (kg) 90/110
Standard Accessory Software, Air compressor, Cu Hollow cathode lamp
Optional Accessory Computer, Printer, Hydride generator, Autosampler

Details of Atomic Absorption Spectrophotometer:

Atomic Absorption Spectrophotometer

Atomic Absorption Spectrophotometer

Atomic Absorption Spectrophotometer

Atomic Absorption Spectrophotometer

Previous: 
Next: 
Get Quotation/Become Distributor

About Company​​​​​​​

As a professional lab and medical equipment manufacturer, Scitek Global is certified by ISO 9001, ISO 13485, ISO 45001 and ISO 14001. Almost all our products are certified by ETL, CE and FDA .

Scitek Global looks forward to establishing cooperation with more distributors all over the world, and working together to create greater customer value.

Quick Links

Contact Us
Scitek Global Co.,Ltd
  No. 7000 Jingshi Road, Jinan City, Shandong Province, China
/  +86-531-82893797
  Inquiry: info@scitekglobal.com
Service: 
service@scitekglobal.com
Complaints: 

complaints@scitekglobal.com
 
Scitek Global Inc.
9999 Bellaire Blvd Ste 505, Houston, TX 77036, United States
  +1 (915) 4126735
info@scitekglobal.net
 
Scitek Ethiopia
 tsion@scitekglobal.com
Copyright © 2023 Scitek Global Co., Ltd. All rights reserved.  Sitemap  Privacy Policy