| Availability: | |
|---|---|
| Quantity: | |
It wirelessly connects to a PC through WIFI, facilitating the wireless transmission of detection data.
Equipped with robust upper computer management software, it efficiently manages multiple detection units simultaneously.
Leveraging RFID chip technology, the glove number is automatically identified and included in the test results.
Compliant with IP65 protection standards, it allows for convenient equipment disinfection and cleaning.
Multiple preset schemes are available to meet the testing requirements for gloves of diverse specifications and materials.
The pressure detection range extends to 3000Pa, encompassing all glove detection pressures.
Incorporates a built-in specialized sanitary air pump for inflating gloves/cuffs.
Automatically monitors pressure in the inflatable sealing ring and the glove during testing.
Utilizes a small, frequent air intake strategy, ensuring uniform air intake speed in the glove to prevent deformation.
Features a color touch screen and user-friendly interface, capable of automatically selecting and matching the testing program that best suits the current glove based on different test parameters, while displaying the date and time.
Designed for easy mobility, portability, and swift connection.
Historical records can be wirelessly transmitted, stored, and easily accessed for reference.
Customizable to customer needs, it offers the option to tailor pallets of various sizes, enabling multiple pallet operations on a single machine.
WGIT-2000 wireless glove integrity tester is a specialized device designed for detecting glove leaks. With years of experience in manufacturing and selling filter integrity testers, our company boasts mature pressure control technology.
This tester utilizes wireless communication, incorporating a built-in air pump and lithium battery. Through systematic management, multiple detection units can be seamlessly linked in real-time. It not only adheres to FDA and GMP requirements but also features four-level authority management and an electronic signature design, aligning with the 21CFR Part 11 electronic records and electronic signature certification standards.
The history record function can store over 12,000 data sets and has its own FLASH storage, enabling the timely transmission and storage of test records. Its simple and refined structural design eliminates the need for additional equipment, allowing for glove tray replacement without glove removal. It supports the detection of gloves with different specifications and sizes.
Equipped with a high-precision pressure sensor, this tester ensures swift and accurate glove testing.
Application Fields:
Pharmaceutical Industry: Sterile inspection and microbial limit inspection of purified water, water for injection, and various sterile preparations.
Medical Equipment Industry: Sterility inspection and microbial limit inspection of purified water, water for injection, syringes, infusion sets, and other medical devices.
Food and Beverage Industry.
Environmental Protection Industry, etc.
| Model | WGIT-1200 | 
|---|---|
| Test Accuracy | Minimum aperture 300µm | 
| Test Duration | 3-6min | 
| Pressure Range | 500-3000Pa | 
| Pressure Resolution | 0.1Pa | 
| Sealing Pressure | ≤ 200 KPa | 
| Noise | ≤50dB(A) | 
| Communication Method | WIFI wireless network | 
| Gas Source | Built-in air pump | 
| History Record | 12000 set | 
| Glove Recognition Method | RFID/manual input | 
| Online Glove Tray | Customizable replacement | 
| Configure the Number of Control Units | Up to 10 test units can be controlled | 
| Control System | Computer control | 
| Built-in Battery | 12V lithium battery | 
| Power Supply | DC 12V 20W | 
| Shipping Size(W×D×H)(mm) | 750x560x600 | 
| G.W. (kg) | 33 | 
It wirelessly connects to a PC through WIFI, facilitating the wireless transmission of detection data.
Equipped with robust upper computer management software, it efficiently manages multiple detection units simultaneously.
Leveraging RFID chip technology, the glove number is automatically identified and included in the test results.
Compliant with IP65 protection standards, it allows for convenient equipment disinfection and cleaning.
Multiple preset schemes are available to meet the testing requirements for gloves of diverse specifications and materials.
The pressure detection range extends to 3000Pa, encompassing all glove detection pressures.
Incorporates a built-in specialized sanitary air pump for inflating gloves/cuffs.
Automatically monitors pressure in the inflatable sealing ring and the glove during testing.
Utilizes a small, frequent air intake strategy, ensuring uniform air intake speed in the glove to prevent deformation.
Features a color touch screen and user-friendly interface, capable of automatically selecting and matching the testing program that best suits the current glove based on different test parameters, while displaying the date and time.
Designed for easy mobility, portability, and swift connection.
Historical records can be wirelessly transmitted, stored, and easily accessed for reference.
Customizable to customer needs, it offers the option to tailor pallets of various sizes, enabling multiple pallet operations on a single machine.
WGIT-2000 wireless glove integrity tester is a specialized device designed for detecting glove leaks. With years of experience in manufacturing and selling filter integrity testers, our company boasts mature pressure control technology.
This tester utilizes wireless communication, incorporating a built-in air pump and lithium battery. Through systematic management, multiple detection units can be seamlessly linked in real-time. It not only adheres to FDA and GMP requirements but also features four-level authority management and an electronic signature design, aligning with the 21CFR Part 11 electronic records and electronic signature certification standards.
The history record function can store over 12,000 data sets and has its own FLASH storage, enabling the timely transmission and storage of test records. Its simple and refined structural design eliminates the need for additional equipment, allowing for glove tray replacement without glove removal. It supports the detection of gloves with different specifications and sizes.
Equipped with a high-precision pressure sensor, this tester ensures swift and accurate glove testing.
Application Fields:
Pharmaceutical Industry: Sterile inspection and microbial limit inspection of purified water, water for injection, and various sterile preparations.
Medical Equipment Industry: Sterility inspection and microbial limit inspection of purified water, water for injection, syringes, infusion sets, and other medical devices.
Food and Beverage Industry.
Environmental Protection Industry, etc.
| Model | WGIT-1200 | 
|---|---|
| Test Accuracy | Minimum aperture 300µm | 
| Test Duration | 3-6min | 
| Pressure Range | 500-3000Pa | 
| Pressure Resolution | 0.1Pa | 
| Sealing Pressure | ≤ 200 KPa | 
| Noise | ≤50dB(A) | 
| Communication Method | WIFI wireless network | 
| Gas Source | Built-in air pump | 
| History Record | 12000 set | 
| Glove Recognition Method | RFID/manual input | 
| Online Glove Tray | Customizable replacement | 
| Configure the Number of Control Units | Up to 10 test units can be controlled | 
| Control System | Computer control | 
| Built-in Battery | 12V lithium battery | 
| Power Supply | DC 12V 20W | 
| Shipping Size(W×D×H)(mm) | 750x560x600 | 
| G.W. (kg) | 33 |