Model | BA-200 |
---|---|
Working Mode | Discrete/random access |
Test Speed | Test speed 180T/H (without ISE) |
Test Principle | Absorbance photometry, Turbidimetry |
Methodology | End-point, Fixed-time, Kinetic, Single/Dual reagent chemistries, monochromatic/bichromatic linear/non-linear multi-point calibration |
The Longest Reaction Time | 15 minutes |
Minimum Reaction Volume | 150μl |
Cuvettes Material | Plastics (quartz glass can be selected), 81 cuvettes have the function of automatically deducting reagent and sample blanks |
Linear Range of Absorbance | 0-3.8Abs |
Halogen Light Source Using Time | ≥ 2000 hours |
Wavelength | 340nm, 405nm, 450nm, 510nm, 546nm, 578nm, 630nm, 670nm |
Refrigeration System | Water medium uniform refrigeration technology |
Reagent Storehouse Temperature | 4-16℃ |
Reaction Temperature | 37±0.2℃ |
Temperature Fluctuation | ±0.1℃ |
Shipping Size(W×D×H)(mm) | 930x730x780 |
N.W./G.W. (kg) | 65/110 |
Sampling and mixing system | |
Sample Capacity | 2-30μl, 0.1μl increasing |
Sample Probe | Sharing with the reagent probe, the inner and outer walls are highly polished, with the function of liquid level detection, tracking and collision protection, sample probe matching special cleaning liquid, prevent cross contamination |
Reagent Capacity | 20-300μl, 0.1μl increasing |
Reagent Probe | Sharing with the sample probe |
Reagent Bottle | Reagent bottles with volume of 15ml, 20ml, 30ml, 50ml, 60ml, 70ml can be used, the dead volume is less than 1ml |
Mixing Bar | Independent mixing bar, special material, surface treatment using Teflon, not hanging liquid, thoroughly clean before and after mixing to prevent cross contamination |
Reagent/sample Handing | |
Reagent/Sample Tray | 60 positions for reagents and 30 positions for samples in refrigerated compartment (4~16℃) |
Reagent Volume | 20-500μl, step by 1μl |
Sample Volume | 2~100μl, step by 0.1μl |
Reagent/Sample Probe | Liquid level detection, collision protection and inventory checking |
Probe Cleaning | Automatic washing for both interior and exterior Carry-over < 0.1% |
Calibration and quality control | |
Quality Control Type | Real time quality control, daily quality control, day to day quality control |
Quality Control Charts | L-J, Cumulative, Twin Plot |
The Quality Control Rules | arbitrarily formulated by default to Westguard multiple rules |
The Calibration Type | linear and nonlinear. Logit-4P, Logit-5P, Spline, exponent, polynomial, factor method |
Calibration | Automatically check the calibration curve and select the best calibration type of the fitting degree automatically |
Operating System | |
English Operating System | Windows2000, windows XP, windows7, windows8, windows10 |
Report Printing | Make print format and content freely, provide several common formats |
User Management | Special user management password, rational distribution of user operation permissions |
Interface | RS-232 standard interface, support for intranet, remote print report |
Databases | Optional various databases, autosave, automatic backup, save all kinds of data permanently |
Real-time monitoring of sample tray, reagents tray, reacting tray; Real-time display of reaction temperature, reagent allowance, reaction curve, calibration curve and quality control chart | |
Check and judge reaction endpoint, reaction linear interval, substrate exhaustion, reagent blank absorbance, etc. | |
Language | English, Chinese |
Provide a variety of print formats, and you can freely select the format and content
Dedicated user management password, reasonable allocation of user operating privileges
Can save measurement data and back up automatically
Test speed 180T/H (without ISE)
30 sample positions and 60 reagent positions
Automatic probe cleaning, liquid level detection, collision protection
Accurate measurements are fast and accurate analyses of various biochemical parameters.
Different biochemical parameters, including blood, urine and other body fluids, can be analyzed.
Model | BA-200 |
---|---|
Working Mode | Discrete/random access |
Test Speed | Test speed 180T/H (without ISE) |
Test Principle | Absorbance photometry, Turbidimetry |
Methodology | End-point, Fixed-time, Kinetic, Single/Dual reagent chemistries, monochromatic/bichromatic linear/non-linear multi-point calibration |
The Longest Reaction Time | 15 minutes |
Minimum Reaction Volume | 150μl |
Cuvettes Material | Plastics (quartz glass can be selected), 81 cuvettes have the function of automatically deducting reagent and sample blanks |
Linear Range of Absorbance | 0-3.8Abs |
Halogen Light Source Using Time | ≥ 2000 hours |
Wavelength | 340nm, 405nm, 450nm, 510nm, 546nm, 578nm, 630nm, 670nm |
Refrigeration System | Water medium uniform refrigeration technology |
Reagent Storehouse Temperature | 4-16℃ |
Reaction Temperature | 37±0.2℃ |
Temperature Fluctuation | ±0.1℃ |
Shipping Size(W×D×H)(mm) | 930x730x780 |
N.W./G.W. (kg) | 65/110 |
Sampling and mixing system | |
Sample Capacity | 2-30μl, 0.1μl increasing |
Sample Probe | Sharing with the reagent probe, the inner and outer walls are highly polished, with the function of liquid level detection, tracking and collision protection, sample probe matching special cleaning liquid, prevent cross contamination |
Reagent Capacity | 20-300μl, 0.1μl increasing |
Reagent Probe | Sharing with the sample probe |
Reagent Bottle | Reagent bottles with volume of 15ml, 20ml, 30ml, 50ml, 60ml, 70ml can be used, the dead volume is less than 1ml |
Mixing Bar | Independent mixing bar, special material, surface treatment using Teflon, not hanging liquid, thoroughly clean before and after mixing to prevent cross contamination |
Reagent/sample Handing | |
Reagent/Sample Tray | 60 positions for reagents and 30 positions for samples in refrigerated compartment (4~16℃) |
Reagent Volume | 20-500μl, step by 1μl |
Sample Volume | 2~100μl, step by 0.1μl |
Reagent/Sample Probe | Liquid level detection, collision protection and inventory checking |
Probe Cleaning | Automatic washing for both interior and exterior Carry-over < 0.1% |
Calibration and quality control | |
Quality Control Type | Real time quality control, daily quality control, day to day quality control |
Quality Control Charts | L-J, Cumulative, Twin Plot |
The Quality Control Rules | arbitrarily formulated by default to Westguard multiple rules |
The Calibration Type | linear and nonlinear. Logit-4P, Logit-5P, Spline, exponent, polynomial, factor method |
Calibration | Automatically check the calibration curve and select the best calibration type of the fitting degree automatically |
Operating System | |
English Operating System | Windows2000, windows XP, windows7, windows8, windows10 |
Report Printing | Make print format and content freely, provide several common formats |
User Management | Special user management password, rational distribution of user operation permissions |
Interface | RS-232 standard interface, support for intranet, remote print report |
Databases | Optional various databases, autosave, automatic backup, save all kinds of data permanently |
Real-time monitoring of sample tray, reagents tray, reacting tray; Real-time display of reaction temperature, reagent allowance, reaction curve, calibration curve and quality control chart | |
Check and judge reaction endpoint, reaction linear interval, substrate exhaustion, reagent blank absorbance, etc. | |
Language | English, Chinese |
Provide a variety of print formats, and you can freely select the format and content
Dedicated user management password, reasonable allocation of user operating privileges
Can save measurement data and back up automatically
Test speed 180T/H (without ISE)
30 sample positions and 60 reagent positions
Automatic probe cleaning, liquid level detection, collision protection
Accurate measurements are fast and accurate analyses of various biochemical parameters.
Different biochemical parameters, including blood, urine and other body fluids, can be analyzed.