Availability: | |
---|---|
Quantity: | |
Model | DO-P510 | |
---|---|---|
Parameters | DO/Temp(DO Saturation). | |
Dissolved Oxygen Concentration | Sensor Type | Polarographic |
Range | 0.00 to 99.99 ppm | |
Resolution | 0.01 ppm | |
Accuracy | ±0.10ppm, 0.00~50.00ppm | |
±0.50ppm, 50.0~99.99ppm | ||
Calibration Reminder | Yes | |
Calibration Points | Air-saturated water or zero point | |
Barometric Compensation | Yes | |
Manual Salinity Factor Correction | Yes | |
DO Saturation | Range | (0.0 to 600.0)% |
Resolution | 0.001 | |
Accuracy | ±2.0% | |
Temperature | Range | -10 to 135 ºC, 14 to 275 ºF |
Unit | ºC, ºF | |
Resolution | 0.1 | |
Relative Accuracy | ±0.1 | |
Measurement | Reading Mode | Auto Read (Fast, Medium, Slow), Timed, Continuous |
Reading Prompts | Reading, Stable, Locked | |
Temp. Compensation | ATC, MTC | |
Data Management | Data Storage | 1000 Groups |
GLP Features | Yes | |
Inputs | DO with Temp. Probe | 4-pin aviation connector |
Outputs | USB | USB 2.0 flash memory device, PC, scanner |
Display Options | Backlight | Yes |
Auto Shutdown | 300, 600, 1200, 1800, 3600 sec., off | |
IP Rating | IP65 | |
Date and Time | Yes | |
General | Electricity | Rechargeable Lithium battery, AC Adapter, 100-240V AC input, DC5V output |
Sizes(W×D×H) | 255×90×40 | |
Shipping Size (W×D×H)(mm) | 410×330×165 | |
N.W./G.W. (kg) | 0.5/5.5 |
DO-P510 is a very convenient dissolved oxygen meter with high sensitivity sensor, which is well adapted to the harsh environment in the field. The instrument utilizes the new measurement technology, eliminating the need to replace the diaphragm and electrolyte and reducing instrument maintenance.
The sensor and the portable dissolved oxygen meter have anti-dislodgement and reinforcement control and can be thrown directly into the water source for testing.
Dissolved oxygen meter features:
It supports real-time measurement, applies to any water source, has strong anti-interference ability, has no polarization, and is stable in size.
Adopts fluorescence dissolved oxygen measurement technology, no need to replace diaphragm and electrolyte, not affected by flow rate, environment and various factors.
Adopting a lithium battery power supply greatly prolongs the instrument's usage time and experience.
Allows the measurement of dissolved oxygen concentration, saturation, and temperature values.
Supports automatic compensation for atmospheric pressure
Support measurement section ID management, allowing users to create 20 measurement sections.
Large storage capacity, allowing the storage of 1000 sets of measurement data.
Support GPS function, the measurement result contains the location information of the measurement section.
Model | DO-P510 | |
---|---|---|
Parameters | DO/Temp(DO Saturation). | |
Dissolved Oxygen Concentration | Sensor Type | Polarographic |
Range | 0.00 to 99.99 ppm | |
Resolution | 0.01 ppm | |
Accuracy | ±0.10ppm, 0.00~50.00ppm | |
±0.50ppm, 50.0~99.99ppm | ||
Calibration Reminder | Yes | |
Calibration Points | Air-saturated water or zero point | |
Barometric Compensation | Yes | |
Manual Salinity Factor Correction | Yes | |
DO Saturation | Range | (0.0 to 600.0)% |
Resolution | 0.001 | |
Accuracy | ±2.0% | |
Temperature | Range | -10 to 135 ºC, 14 to 275 ºF |
Unit | ºC, ºF | |
Resolution | 0.1 | |
Relative Accuracy | ±0.1 | |
Measurement | Reading Mode | Auto Read (Fast, Medium, Slow), Timed, Continuous |
Reading Prompts | Reading, Stable, Locked | |
Temp. Compensation | ATC, MTC | |
Data Management | Data Storage | 1000 Groups |
GLP Features | Yes | |
Inputs | DO with Temp. Probe | 4-pin aviation connector |
Outputs | USB | USB 2.0 flash memory device, PC, scanner |
Display Options | Backlight | Yes |
Auto Shutdown | 300, 600, 1200, 1800, 3600 sec., off | |
IP Rating | IP65 | |
Date and Time | Yes | |
General | Electricity | Rechargeable Lithium battery, AC Adapter, 100-240V AC input, DC5V output |
Sizes(W×D×H) | 255×90×40 | |
Shipping Size (W×D×H)(mm) | 410×330×165 | |
N.W./G.W. (kg) | 0.5/5.5 |
DO-P510 is a very convenient dissolved oxygen meter with high sensitivity sensor, which is well adapted to the harsh environment in the field. The instrument utilizes the new measurement technology, eliminating the need to replace the diaphragm and electrolyte and reducing instrument maintenance.
The sensor and the portable dissolved oxygen meter have anti-dislodgement and reinforcement control and can be thrown directly into the water source for testing.
Dissolved oxygen meter features:
It supports real-time measurement, applies to any water source, has strong anti-interference ability, has no polarization, and is stable in size.
Adopts fluorescence dissolved oxygen measurement technology, no need to replace diaphragm and electrolyte, not affected by flow rate, environment and various factors.
Adopting a lithium battery power supply greatly prolongs the instrument's usage time and experience.
Allows the measurement of dissolved oxygen concentration, saturation, and temperature values.
Supports automatic compensation for atmospheric pressure
Support measurement section ID management, allowing users to create 20 measurement sections.
Large storage capacity, allowing the storage of 1000 sets of measurement data.
Support GPS function, the measurement result contains the location information of the measurement section.