| Quantity: | |
| Model | DO-PS60 |
|---|---|
| Range | 0.00-20.00mg/L,0.0-200.0% saturation |
| Resolution | 0.01mg/L, 0.1% |
| Accuracy | ±0.2mg/L, ±2.0% |
| Calibration Points | 1 or 2 points |
| Temperature Compensation | 0-50°C/32-122°F, automatic |
| Barometric Pressure Correction | 60.0-113.3kPa/450-850mmHg. manual |
| Salinity Correction | 0.0-50.0g/L, manual |
| Measurement Modes | Dissolved oxygen, BOD, oxygen uptake rate, specific oxygen uptake rate |
| Stability Criteria | Fast, standard,slow |
| Measurement Modes | Continuous or auto-read |
| Timed Interval Readings | 10, 30, 60, 300 seconds or off |
| Calibration Due Alarm | 1 to 99 days or off |
| Data Transfer | Send to memory or printer |
| Power Requirements | 2×1.2V lithium batteries or AAA batteries |
| Sizes(W×D×H) | 175 (L)x 40 (Dia.) |
| Shipping Size (W×D×H)(mm) | 280x80x250 |
| N.W./G.W. (kg) | 0.1/1.5 |
Pocket dissolved oxygen tester is an advanced device that allows easy and flexible measurement of dissolved oxygen levels in liquids. It typically uses bluetooth technology to wirelessly transmit data to a computer or other device for further analysis or recording. The menu supports a customized setting of 15 functional parameters suitable for measuring dissolved oxygen, BOD, oxygen uptake rate, and specific oxygen uptake rate of the sample.
A measurement accuracy of 0.2mg/L is essential to maintain optimal conditions.
Fast response and high sensor sensitivity
The data management function provides detailed BOD information, including date/time, temperature, and initial/final DO.
Salinity and atmospheric pressure compensation eliminates measurement errors.
Wireless connectivity for flexibility and ease of operation
Selectable test times start/end DO to calculate OUR and SOUR.
| Model | DO-PS60 |
|---|---|
| Range | 0.00-20.00mg/L,0.0-200.0% saturation |
| Resolution | 0.01mg/L, 0.1% |
| Accuracy | ±0.2mg/L, ±2.0% |
| Calibration Points | 1 or 2 points |
| Temperature Compensation | 0-50°C/32-122°F, automatic |
| Barometric Pressure Correction | 60.0-113.3kPa/450-850mmHg. manual |
| Salinity Correction | 0.0-50.0g/L, manual |
| Measurement Modes | Dissolved oxygen, BOD, oxygen uptake rate, specific oxygen uptake rate |
| Stability Criteria | Fast, standard,slow |
| Measurement Modes | Continuous or auto-read |
| Timed Interval Readings | 10, 30, 60, 300 seconds or off |
| Calibration Due Alarm | 1 to 99 days or off |
| Data Transfer | Send to memory or printer |
| Power Requirements | 2×1.2V lithium batteries or AAA batteries |
| Sizes(W×D×H) | 175 (L)x 40 (Dia.) |
| Shipping Size (W×D×H)(mm) | 280x80x250 |
| N.W./G.W. (kg) | 0.1/1.5 |
Pocket dissolved oxygen tester is an advanced device that allows easy and flexible measurement of dissolved oxygen levels in liquids. It typically uses bluetooth technology to wirelessly transmit data to a computer or other device for further analysis or recording. The menu supports a customized setting of 15 functional parameters suitable for measuring dissolved oxygen, BOD, oxygen uptake rate, and specific oxygen uptake rate of the sample.
A measurement accuracy of 0.2mg/L is essential to maintain optimal conditions.
Fast response and high sensor sensitivity
The data management function provides detailed BOD information, including date/time, temperature, and initial/final DO.
Salinity and atmospheric pressure compensation eliminates measurement errors.
Wireless connectivity for flexibility and ease of operation
Selectable test times start/end DO to calculate OUR and SOUR.