Availability: | |
---|---|
Quantity: | |
LCD display screen, 3.5 inches.
Multi-reading feature allows auto-read and continuous-read.
Automatic/Manual temperature compensation ensures accurate results.
Auto-hold feature senses and locks the measurement endpoint.
Data capacity of up to 200 sets for each parameter.
Auto-power off feature effectively extends the battery service life.
Reset feature automatically resumes all settings back to factory default options.
IP65 waterproof. The portable meter is suitable for fields measurements and out door measurements.
1 point calibration with Standard Recognition.
Cell constant is settable
Automatic/manual temperature compensation ensures accurate results.
Model | EC210E | |
---|---|---|
Parameters | EC/Temp.(TDS) | |
Conductivity | Range | 0.00 μS/cm to 200 mS/cm |
Resolution | 0.01 μS/cm minimum, various with range selection | |
Accuracy | ±1.0% FS | |
Reference Temperature | 25 ºC | |
Calibration Points | Up to 1 | |
Standard Recognition | 84μS/cm, 1413μS/cm, 12.88mS/cm | |
TDS | Range | 0.00mg/L~300g/L |
Resolution | 0.01mg/L minimum, various with range selection | |
Accuracy | ±1.0%FS | |
Temperature | Range | -5 to 110 ℃ |
Unit | ℃ | |
Resolution | 0.1℃ | |
Accuracy | ±0.2 ℃ | |
Measurement | Reading Mode | Auto Read, Continuous |
Reading Prompts | Reading, Stable, Locked | |
Temp. Compensation | ATC, MTC | |
Data Management | Data Storage | 200 results each |
Inputs | Conductivity with Temp. Probe | 5-pin aviation connector |
Display Options | Backlight | Yes |
Auto Shutdown | 300, 600, 1200, 1800, 3600 sec., off | |
IP Rating | IP65 | |
General | Power | Rechargeable Lithium battery, AC Adapter, 100-240V AC input, DC5V output |
Sizes(W×D×H) | 80×255×35 | |
Shipping Size (W×D×H)(mm) | 300×290×140 | |
N.W. (kg) | 400g (0.88 lb) | |
G.W. (kg) | 1 | |
Includes | Accessories | DJS-1VTC EC electrode 1413μS/cm EC standard solution, 50ml, 1 vial Electrode holder Silicone rubber case Wristbands |
LCD display screen, 3.5 inches.
Multi-reading feature allows auto-read and continuous-read.
Automatic/Manual temperature compensation ensures accurate results.
Auto-hold feature senses and locks the measurement endpoint.
Data capacity of up to 200 sets for each parameter.
Auto-power off feature effectively extends the battery service life.
Reset feature automatically resumes all settings back to factory default options.
IP65 waterproof. The portable meter is suitable for fields measurements and out door measurements.
1 point calibration with Standard Recognition.
Cell constant is settable
Automatic/manual temperature compensation ensures accurate results.
Model | EC210E | |
---|---|---|
Parameters | EC/Temp.(TDS) | |
Conductivity | Range | 0.00 μS/cm to 200 mS/cm |
Resolution | 0.01 μS/cm minimum, various with range selection | |
Accuracy | ±1.0% FS | |
Reference Temperature | 25 ºC | |
Calibration Points | Up to 1 | |
Standard Recognition | 84μS/cm, 1413μS/cm, 12.88mS/cm | |
TDS | Range | 0.00mg/L~300g/L |
Resolution | 0.01mg/L minimum, various with range selection | |
Accuracy | ±1.0%FS | |
Temperature | Range | -5 to 110 ℃ |
Unit | ℃ | |
Resolution | 0.1℃ | |
Accuracy | ±0.2 ℃ | |
Measurement | Reading Mode | Auto Read, Continuous |
Reading Prompts | Reading, Stable, Locked | |
Temp. Compensation | ATC, MTC | |
Data Management | Data Storage | 200 results each |
Inputs | Conductivity with Temp. Probe | 5-pin aviation connector |
Display Options | Backlight | Yes |
Auto Shutdown | 300, 600, 1200, 1800, 3600 sec., off | |
IP Rating | IP65 | |
General | Power | Rechargeable Lithium battery, AC Adapter, 100-240V AC input, DC5V output |
Sizes(W×D×H) | 80×255×35 | |
Shipping Size (W×D×H)(mm) | 300×290×140 | |
N.W. (kg) | 400g (0.88 lb) | |
G.W. (kg) | 1 | |
Includes | Accessories | DJS-1VTC EC electrode 1413μS/cm EC standard solution, 50ml, 1 vial Electrode holder Silicone rubber case Wristbands |