Availability: | |
---|---|
Quantity: | |
Model | CON-P520 | CON-TP530 | CON-SP531 | CON-TSRP540 | |
---|---|---|---|---|---|
Conductivity | Range | 0.01~20.00, 200.0, 2000µS/cm, 20.00, 200.0mS/cm | |||
Resolution | 0.001,0.01,0.1,1 | ||||
Accuracy | ±0.5% F.S. | ||||
Calibration Points | 1 to 3 points (CON-P520), 1 to 5 points (others) | ||||
Calibration Solutions | 10µS/cm, 84µS/cm, 1413µS/cm, 12.88mS/cm, 111.8mS/cm | ||||
TDS | Range | — | 0~10.00, 100.0, 1000ppm, 10.00, 200.0ppt | — | 0~10.00, 100.0, 1000ppm, 10.00, 200.0ppt |
Resolution | — | 0.01, 0.1, 1 | — | 0.01, 0.1, 1 | |
Accuracy | — | ±1%FS. | — | ±1%FS. | |
TDS Factor | — | 0.1~1.0 (default 0.5) | — | 0.1~1.0 (default 0.5) | |
Salinity | Range | — | 一 | 0.00~42.00psu, 0.00~ 80.00ppt | 0.00~42.00psu, 0.00~80.00ppt |
Resolution | — | 一 | 0.01 | 0.01 | |
Accuracy | — | 一 | ±1% F.S. | ±1% F.S. | |
Resistivity | Range | — | 一 | — | 0.00~20.00MΩ |
Resolution | — | 一 | — | 0.01 | |
Accuracy | — | 一 | — | ±1% FS. | |
Temperature | Range | 0~105°C/32~221°F | |||
Resolution | 0.1°C/0.1°F | ||||
Accuracy | ±0.5°C/±0.9°F | ||||
Offset Calibration | 1 point, reading ±10°C | ||||
Other Specifications | Temperature Compensation | 0~100°C, manual or automatic | |||
Temperature Coefficient | Linear (0.0~10.0%/°C), non-linear, pure water | ||||
Reference Temperature | 20/25℃ | ||||
Cell Constant | K=0.1, 1, 10 | ||||
Stability Criteria | — | Low ar high | Low ar high | Low ar high | |
Calibration Due Alarm | — | 1 to 31 days or off | 1 to 31 days or off | 1 to 31 days or off | |
Hold Function | Manual or auto endpoint | ||||
Auto-Off | 30 minutes after last key pressed | — | — | — | |
— | 10, 20 or 30 minutes after last key pressed | ||||
Memory | 100 data sets (CON-P520), 500 data sets (others) | ||||
Communication Interface | USB | ||||
Connector | 6-pin mini-DIN, 3.5mm jack socket | ||||
Display | Custom LCD (80×60mm) | ||||
Power Requirements | 3×1.5V AA batteries or DC 5V power adapter | ||||
Battery Life | Approximately 150 hours(Turn off the backlight) | ||||
Sizes(W×D×H) | 170×85x30 | ||||
Shipping Size (W×D×H)(mm) | 350x10x300 | ||||
N.W./G.W. (kg) | 0.3/1.5 |
Several multi-parameter portable conductivity meters support the measurement of conductivity, pH, TDS, temperature, salinity, and resistivity.
Portable conductivity meters are small in size, easy to carry, and have reinforced and waterproof protection for the case and sensor, which can be used for a variety of outdoor testing.
1 to 5 point calibration, automatic recognition of conductivity standards. Measurement accuracy: 0.5% F.S. These portable conductivity meters are suitable for use in a variety of industries such as experimental research, school education, and aquaculture. Optional electrode constant (K=0.1/1/10), reference temperature (20/25°C), TDS conversion factor, linear and pure water compensation modes.
Automatic temperature compensation, corrects conductivity measurements and converts readings to reference temperature.
Automatic endpoint lock, retains stable readings for easy viewing and recording.
Calibration report, showing calibration points and conductivity cell coefficients.
Automatic power off, saving battery power.
Reset function automatically restores meter to factory default settings.
Expandable memory to store or access up to 500 data sets.
USB interface, easy to transfer data to PC.
Multi-mode power supply ensures smooth application of the meter.
The interior also features a foam cushioning layer and a fixing slot to prevent vibration and shock during transport. Three bottles of calibration solution are included.
Professional pre-sales and after-sales service teams provide detailed instruction and technical support to ensure your experience is smooth and worry-free.
Our portable conductivity meters are reasonably priced and have good cost performance.
Efficient logistics network, to ensure that you receive the product in the shortest possible time, reducing the waiting time
How do I Calibrate the Portable Conductivity Meter?
The initial calibration is done at the factory. To ensure accuracy, you can switch on the instrument and enter the calibration mode, then dip the conductivity probe into our complimentary calibration solution. Follow the portable conductivity meter's instructions to adjust the reading to match the known conductivity value of the calibration solution. Refer to the user manual for detailed calibration procedures.
What is the service life of a conductivity probe?
The service life of a conductivity probe depends on the frequency of use and the environment in which it is used. Generally, probes will last 1 to 2 years with normal use and maintenance. Regular cleaning and calibration will extend the life of the probe.
Model | CON-P520 | CON-TP530 | CON-SP531 | CON-TSRP540 | |
---|---|---|---|---|---|
Conductivity | Range | 0.01~20.00, 200.0, 2000µS/cm, 20.00, 200.0mS/cm | |||
Resolution | 0.001,0.01,0.1,1 | ||||
Accuracy | ±0.5% F.S. | ||||
Calibration Points | 1 to 3 points (CON-P520), 1 to 5 points (others) | ||||
Calibration Solutions | 10µS/cm, 84µS/cm, 1413µS/cm, 12.88mS/cm, 111.8mS/cm | ||||
TDS | Range | — | 0~10.00, 100.0, 1000ppm, 10.00, 200.0ppt | — | 0~10.00, 100.0, 1000ppm, 10.00, 200.0ppt |
Resolution | — | 0.01, 0.1, 1 | — | 0.01, 0.1, 1 | |
Accuracy | — | ±1%FS. | — | ±1%FS. | |
TDS Factor | — | 0.1~1.0 (default 0.5) | — | 0.1~1.0 (default 0.5) | |
Salinity | Range | — | 一 | 0.00~42.00psu, 0.00~ 80.00ppt | 0.00~42.00psu, 0.00~80.00ppt |
Resolution | — | 一 | 0.01 | 0.01 | |
Accuracy | — | 一 | ±1% F.S. | ±1% F.S. | |
Resistivity | Range | — | 一 | — | 0.00~20.00MΩ |
Resolution | — | 一 | — | 0.01 | |
Accuracy | — | 一 | — | ±1% FS. | |
Temperature | Range | 0~105°C/32~221°F | |||
Resolution | 0.1°C/0.1°F | ||||
Accuracy | ±0.5°C/±0.9°F | ||||
Offset Calibration | 1 point, reading ±10°C | ||||
Other Specifications | Temperature Compensation | 0~100°C, manual or automatic | |||
Temperature Coefficient | Linear (0.0~10.0%/°C), non-linear, pure water | ||||
Reference Temperature | 20/25℃ | ||||
Cell Constant | K=0.1, 1, 10 | ||||
Stability Criteria | — | Low ar high | Low ar high | Low ar high | |
Calibration Due Alarm | — | 1 to 31 days or off | 1 to 31 days or off | 1 to 31 days or off | |
Hold Function | Manual or auto endpoint | ||||
Auto-Off | 30 minutes after last key pressed | — | — | — | |
— | 10, 20 or 30 minutes after last key pressed | ||||
Memory | 100 data sets (CON-P520), 500 data sets (others) | ||||
Communication Interface | USB | ||||
Connector | 6-pin mini-DIN, 3.5mm jack socket | ||||
Display | Custom LCD (80×60mm) | ||||
Power Requirements | 3×1.5V AA batteries or DC 5V power adapter | ||||
Battery Life | Approximately 150 hours(Turn off the backlight) | ||||
Sizes(W×D×H) | 170×85x30 | ||||
Shipping Size (W×D×H)(mm) | 350x10x300 | ||||
N.W./G.W. (kg) | 0.3/1.5 |
Several multi-parameter portable conductivity meters support the measurement of conductivity, pH, TDS, temperature, salinity, and resistivity.
Portable conductivity meters are small in size, easy to carry, and have reinforced and waterproof protection for the case and sensor, which can be used for a variety of outdoor testing.
1 to 5 point calibration, automatic recognition of conductivity standards. Measurement accuracy: 0.5% F.S. These portable conductivity meters are suitable for use in a variety of industries such as experimental research, school education, and aquaculture. Optional electrode constant (K=0.1/1/10), reference temperature (20/25°C), TDS conversion factor, linear and pure water compensation modes.
Automatic temperature compensation, corrects conductivity measurements and converts readings to reference temperature.
Automatic endpoint lock, retains stable readings for easy viewing and recording.
Calibration report, showing calibration points and conductivity cell coefficients.
Automatic power off, saving battery power.
Reset function automatically restores meter to factory default settings.
Expandable memory to store or access up to 500 data sets.
USB interface, easy to transfer data to PC.
Multi-mode power supply ensures smooth application of the meter.
The interior also features a foam cushioning layer and a fixing slot to prevent vibration and shock during transport. Three bottles of calibration solution are included.
Professional pre-sales and after-sales service teams provide detailed instruction and technical support to ensure your experience is smooth and worry-free.
Our portable conductivity meters are reasonably priced and have good cost performance.
Efficient logistics network, to ensure that you receive the product in the shortest possible time, reducing the waiting time
How do I Calibrate the Portable Conductivity Meter?
The initial calibration is done at the factory. To ensure accuracy, you can switch on the instrument and enter the calibration mode, then dip the conductivity probe into our complimentary calibration solution. Follow the portable conductivity meter's instructions to adjust the reading to match the known conductivity value of the calibration solution. Refer to the user manual for detailed calibration procedures.
What is the service life of a conductivity probe?
The service life of a conductivity probe depends on the frequency of use and the environment in which it is used. Generally, probes will last 1 to 2 years with normal use and maintenance. Regular cleaning and calibration will extend the life of the probe.