12.1 inch color display with 800x600 resolution
Three Working Modes: Monitoring, Surgery and Diagnosis
Simple and friendly operating display interface.
Multi-display modes suitable for different applications:Standard Interface, Large font, ECG Standard Full Display OXY, Trend Table, BP Trend.
Built-in rechargeable Lithium battery up to 3 hours of continuous work.
VGA output for external displa
Model | MPM-II | ||
---|---|---|---|
ECG | Lead Mode | 5 Leads (I, II, III, AVR, AVL, AVF, V) | |
Gain | 2.5mm/mV; 5.0mm/mV; 10mm/mV; 20mm/mV | ||
Heart Rate | Heart Rate | 15-300 BPM (Adult); 15-350 BPM (Neonatal) | |
Resolution | 1 BPM | ||
Accuracy | ±1% | ||
Sensitivity | >200 uV(Peak to peak) | ||
ST Measurement Range | Measurement Range | -2.0 ~ +2.0 mV | |
Accuracy | -0.8mV~+0.8mV: +0.02mV or ±10%, which is greater | ||
Other Range | unspecified | ||
Sweep Speed | 12.5 mm/s, 25mm/s, 50mm/s | ||
Bandwidth | Diagnostic | 0.05~130 Hz | |
Monitor | 0.5~40 Hz | ||
Surgery | 1~20 Hz | ||
SpO2 | Measuring Range | 0~100 % | |
Resolution | 1% | ||
Accuracy | 70%~100% (±2 %) | ||
Pulse Rate | Range | 20-250 BPM | |
Resolution | 1 BPM | ||
Accuracy | ±3 BPM | ||
Optional Parameters: | Recorder (Printer) | ||
Central monitoring system | |||
Dual IBP | |||
Etco2 | |||
12-lead ECG | |||
Nellcor SpO2 | |||
Sun Tech NIBP | |||
NIBP | Method | Oscillometry | |
Measure Mode | Manual, Auto, STAT | ||
Unit | mmHg, kPa | ||
Measure and alarm range: | |||
Adult Mode | SYS | 40~280mmHg | |
DIA | 10~225 mmHg | ||
MEAN | 20~240 mmHg | ||
Pediatric Mode | SYS | 40~220 mmHg | |
DIA | 10~160 mmHg | ||
MEAN | 20~170 mmHg | ||
Neonatal Mode | SYS | 40~135 mmHg | |
DIA | 10~100 mmHg | ||
MEAN | 20 ~110 mmHg | ||
Resolution | 1 mmHg | ||
Accuracy | ±5 mmHg | ||
TEMP | Measure and Alarm Range | 0~50℃ | |
Resolution | 0.1℃ | ||
Accuracy | ±0.1℃ | ||
RESP | Method | lmpedance between RA-LI or RALA | |
Measurement Range | Adult | 10~120 BrPM | |
Neonatal/Pediatric | 7~150 BrPM | ||
Resolution | 1 BrPM | ||
Accuracy | ±2 BrPM | ||
Power Supply | AC100-240V, 50/60Hz | ||
Shipping Size(W×D×H)(mm) | 370x280x360 | ||
G.W. (kg) | 4.5 | ||
Standard Configuration | |||
No. | ltem | Qty | |
1 | Main Unit | 1 | |
2 | 5-lead ECG Cable | 1 | |
3 | Disposable ECG Electrode | 5 | |
4 | Adult SpO2 Probe | 1 | |
5 | Adult NIBP Cuff | 1 | |
6 | Temperature Probe | 1 | |
7 | NlBP Extension Tube | 1 | |
8 | Power Cable | 1 | |
9 | User Manual | 1 | |
10 | Fuse | 3 |
12.1 inch color display with 800x600 resolution
Three Working Modes: Monitoring, Surgery and Diagnosis
Simple and friendly operating display interface.
Multi-display modes suitable for different applications:Standard Interface, Large font, ECG Standard Full Display OXY, Trend Table, BP Trend.
Built-in rechargeable Lithium battery up to 3 hours of continuous work.
VGA output for external displa
Model | MPM-II | ||
---|---|---|---|
ECG | Lead Mode | 5 Leads (I, II, III, AVR, AVL, AVF, V) | |
Gain | 2.5mm/mV; 5.0mm/mV; 10mm/mV; 20mm/mV | ||
Heart Rate | Heart Rate | 15-300 BPM (Adult); 15-350 BPM (Neonatal) | |
Resolution | 1 BPM | ||
Accuracy | ±1% | ||
Sensitivity | >200 uV(Peak to peak) | ||
ST Measurement Range | Measurement Range | -2.0 ~ +2.0 mV | |
Accuracy | -0.8mV~+0.8mV: +0.02mV or ±10%, which is greater | ||
Other Range | unspecified | ||
Sweep Speed | 12.5 mm/s, 25mm/s, 50mm/s | ||
Bandwidth | Diagnostic | 0.05~130 Hz | |
Monitor | 0.5~40 Hz | ||
Surgery | 1~20 Hz | ||
SpO2 | Measuring Range | 0~100 % | |
Resolution | 1% | ||
Accuracy | 70%~100% (±2 %) | ||
Pulse Rate | Range | 20-250 BPM | |
Resolution | 1 BPM | ||
Accuracy | ±3 BPM | ||
Optional Parameters: | Recorder (Printer) | ||
Central monitoring system | |||
Dual IBP | |||
Etco2 | |||
12-lead ECG | |||
Nellcor SpO2 | |||
Sun Tech NIBP | |||
NIBP | Method | Oscillometry | |
Measure Mode | Manual, Auto, STAT | ||
Unit | mmHg, kPa | ||
Measure and alarm range: | |||
Adult Mode | SYS | 40~280mmHg | |
DIA | 10~225 mmHg | ||
MEAN | 20~240 mmHg | ||
Pediatric Mode | SYS | 40~220 mmHg | |
DIA | 10~160 mmHg | ||
MEAN | 20~170 mmHg | ||
Neonatal Mode | SYS | 40~135 mmHg | |
DIA | 10~100 mmHg | ||
MEAN | 20 ~110 mmHg | ||
Resolution | 1 mmHg | ||
Accuracy | ±5 mmHg | ||
TEMP | Measure and Alarm Range | 0~50℃ | |
Resolution | 0.1℃ | ||
Accuracy | ±0.1℃ | ||
RESP | Method | lmpedance between RA-LI or RALA | |
Measurement Range | Adult | 10~120 BrPM | |
Neonatal/Pediatric | 7~150 BrPM | ||
Resolution | 1 BrPM | ||
Accuracy | ±2 BrPM | ||
Power Supply | AC100-240V, 50/60Hz | ||
Shipping Size(W×D×H)(mm) | 370x280x360 | ||
G.W. (kg) | 4.5 | ||
Standard Configuration | |||
No. | ltem | Qty | |
1 | Main Unit | 1 | |
2 | 5-lead ECG Cable | 1 | |
3 | Disposable ECG Electrode | 5 | |
4 | Adult SpO2 Probe | 1 | |
5 | Adult NIBP Cuff | 1 | |
6 | Temperature Probe | 1 | |
7 | NlBP Extension Tube | 1 | |
8 | Power Cable | 1 | |
9 | User Manual | 1 | |
10 | Fuse | 3 |