Availability: | |
---|---|
Quantity: | |
Model | TS-IV |
---|---|
Capacity | 6pcs slides in each holder, for continuous staining process |
Numbers of Station | 20pcs, (Repeat Station, Clean Bath can be set) |
Volume of Station | 135ml |
Length of Processing Time in the Cup | Adjustable within 0 - 59 minutes and within 0 - 59 seconds |
Time for Changing Station, Stay and Leaching Liquid | 10S |
Numbers of Program | 10pcs, with remind code for online faulty |
Power Supply | AC220V±10% 50Hz / AC110V±10% 60Hz |
Power | 100W |
Shipping Size(W×D×H)(mm) | 840×450×550 |
N.W./G.W. (kg) | 32/40 |
This fully automatic tissue slide stainer finds applications in various settings such as hospitals, medical colleges, sanitation and anti-epidemic stations, and biological research laboratories. It offers numerous advantages, including rapid staining, user-friendly operation, and safety features. The unit is equipped with an optical plastic cover and an air exhaust system for enhanced safety and environmental considerations. Additionally, it boasts a slide rack that can be placed at any station and operates through self-induction, ensuring efficient staining processes.
Compact unit with an LED touch-operated system, featuring an innovative mechanical arm design with minimal energy consumption.
Allows for sample addition at any time to enable continuous staining.
Supports setting multiple repeat stations when one station requires more time, facilitating expedited staining processes.
Stations from No.2 to No.17 can be configured for water cleaning. It features Auto Start/Stop for cleaning and adjustable water flow to meet specific needs.
Any station can be designated as the endpoint, signaling completion with an audible alert.
The automatic tissue slide stainer is equipped with a water protection device that automatically shuts off water in case of blockage and provides a warning notification.
Allows the flexibility to change stations during the automated staining process.
Staining progress is visually represented by a dynamic graph for real-time monitoring.
The automated slide stainer is equipped with safety features designed for consistent, high-quality results.
The slide holder is partially inserted into the automated slide stainer, ensuring precise handling of tissue sections and automated staining.
The blue transparent cover allows for easy viewing during the staining process.
The control panel of the stainer allows precise control of staining parameters.
The automated slide stainer's internal multiple slides are arranged in slide holders ready for staining. The internal mechanism is designed for efficient and even application of reagents.
Loading Slides: Slides containing tissue or cell samples are loaded into slide holders and placed into the automated staining machine.
Reagent Application: The Tissue slide stainer automatically dispenses specific staining reagents onto the slide.
Time Control: The Tissue slide stainer controls the application time of each reagent to ensure consistent staining results.
Wash: After using the staining reagents, the machine automatically rinses the slide with buffer or water to remove excess reagent.
Unloading: When the staining process is complete, the slide will be automatically unloaded or made available for manual retrieval.
Model | TS-IV |
---|---|
Capacity | 6pcs slides in each holder, for continuous staining process |
Numbers of Station | 20pcs, (Repeat Station, Clean Bath can be set) |
Volume of Station | 135ml |
Length of Processing Time in the Cup | Adjustable within 0 - 59 minutes and within 0 - 59 seconds |
Time for Changing Station, Stay and Leaching Liquid | 10S |
Numbers of Program | 10pcs, with remind code for online faulty |
Power Supply | AC220V±10% 50Hz / AC110V±10% 60Hz |
Power | 100W |
Shipping Size(W×D×H)(mm) | 840×450×550 |
N.W./G.W. (kg) | 32/40 |
This fully automatic tissue slide stainer finds applications in various settings such as hospitals, medical colleges, sanitation and anti-epidemic stations, and biological research laboratories. It offers numerous advantages, including rapid staining, user-friendly operation, and safety features. The unit is equipped with an optical plastic cover and an air exhaust system for enhanced safety and environmental considerations. Additionally, it boasts a slide rack that can be placed at any station and operates through self-induction, ensuring efficient staining processes.
Compact unit with an LED touch-operated system, featuring an innovative mechanical arm design with minimal energy consumption.
Allows for sample addition at any time to enable continuous staining.
Supports setting multiple repeat stations when one station requires more time, facilitating expedited staining processes.
Stations from No.2 to No.17 can be configured for water cleaning. It features Auto Start/Stop for cleaning and adjustable water flow to meet specific needs.
Any station can be designated as the endpoint, signaling completion with an audible alert.
The automatic tissue slide stainer is equipped with a water protection device that automatically shuts off water in case of blockage and provides a warning notification.
Allows the flexibility to change stations during the automated staining process.
Staining progress is visually represented by a dynamic graph for real-time monitoring.
The automated slide stainer is equipped with safety features designed for consistent, high-quality results.
The slide holder is partially inserted into the automated slide stainer, ensuring precise handling of tissue sections and automated staining.
The blue transparent cover allows for easy viewing during the staining process.
The control panel of the stainer allows precise control of staining parameters.
The automated slide stainer's internal multiple slides are arranged in slide holders ready for staining. The internal mechanism is designed for efficient and even application of reagents.
Loading Slides: Slides containing tissue or cell samples are loaded into slide holders and placed into the automated staining machine.
Reagent Application: The Tissue slide stainer automatically dispenses specific staining reagents onto the slide.
Time Control: The Tissue slide stainer controls the application time of each reagent to ensure consistent staining results.
Wash: After using the staining reagents, the machine automatically rinses the slide with buffer or water to remove excess reagent.
Unloading: When the staining process is complete, the slide will be automatically unloaded or made available for manual retrieval.