Availability: | |
---|---|
Quantity: | |
Model | US-120 |
---|---|
Test Parameters | Normal RBC, Standing RBC, Dysmorpuic RBC, Normal WBC, WBCC, Pus Cell, Hyaline Cast, Granular Cast, WBC Cast, Squamous Epithelial Cell, Normal Epithelial Cell, Sperm, Calcium Crystal, Oxalate Crystal Bacteria, Yeast, Amorphous Urates, Mucus etc. |
Test Principle | Flow cell digital imaging technology, medical image fusion technology, artificial intelligence identification technique |
Channel | Four channels fixed flow counting cell |
Sample Volume | Minimum volume: 3mL, Aspiration volume: 1mL |
Test Speed | 120 samples/hour |
Aspiration Volume | 1ml |
Test Sensitivity | 5 cells/μL |
Accuracy | >95% |
Repeatability | CV<10% |
Cross Contamination Rate | <0.05% |
Data Storage | 200000 |
Report Mode | International general quantitative unit; unit /μL&HPF, complete and illustrated report, with urine chemistry test results and urine sediment test results |
Environment | Temperature: 15°C~35°C |
Optimum temperature: 20°C~25°C | |
Relative humidity: ≤75% | |
Power Supply | AC220V±10%, 50Hz |
Sizes(W×D×H)(mm) | 660x440x570 |
Shipping Size (W×D×H)(mm) | 1170x780x790 |
N.W./G.W. (kg) | 47/100 |
Four channels fixed flow counting cell channel design, channel settlement, cleaning and other detection functions fully guarantee the speed and efficiency of specimen testing. An fully automatic urine sediment analyzer with a channel detection of other channels of sedimentation cleaning function maximizes the savings in testing time.
The microscope automatically ensures that the sample shooting is clear and complete, reducing maintenance costs.
The operator can modify targets misjudged by the instrument. Memory can be stored and automatically modeled after training is completed.
Automatic positioning, tracking, scanning, identification, classification, counting and analysis of components formed in urine using flow counting cells, medical image information scanning technology and artificial vision visual recognition technology.
Fully automated 10-tube orbital sample grating automatically detects the continuous feeding of samples, and the sample area to be analyzed can hold up to 60 samples at a time.
Samples are automatically scanned and positioned at a true distance, requiring no centrifugation, direct detection of original urine, automatic aspiration, and mixing.
The urine sediment analyzer adops of high-precision plated PTFE suction needle and more thorough cleaning of the instrument pipeline, as far as possible, to eliminate cross-contamination.
Fully Automatic Urine Sediment Analyzer Display
An indispensable component that ensures the proper functioning of the urine sediment analyzer display and the accuracy of the samples analysed.
Routine urinalysis
Diagnosis of urinary tract infections
Renal Function Assessment
Screening for urinary stones
Urine monitoring during pregnancy
The fully automatic urine sediment analyzer has a wide range of applications in clinical practice, improving the accuracy, efficiency and standardisation of urinalysis and providing doctors with more reliable diagnostic and therapeutic support.
Urine analyzer can be analysed in its natural state without the need for centrifugation, which can destroy fragile components. Results are quantified in cells/μL, minimising subjectivity. The operating time is minimised and the focus is on qualitative results.
No. Urine sediment analyzer in its natural state can be evaluated without centrifugation. The sample still needs to be gently stirred before analysis, but there is no need to centrifuge the urine, thus saving time and optimising sample quality.
Using an optical lens and image analysis technology, it automatically identifies, counts and analyses a wide range of cells, crystals and other particles in the urine sediment. It uses advanced algorithms and databases to identify and classify different types of cells and crystals and generate quantitative results. This automated system greatly improves efficiency and reduces human error, making urinary sediment analysis more accurate and reliable.
Minimal automated maintenance features save time and eliminate staff frustration.
Model | US-120 |
---|---|
Test Parameters | Normal RBC, Standing RBC, Dysmorpuic RBC, Normal WBC, WBCC, Pus Cell, Hyaline Cast, Granular Cast, WBC Cast, Squamous Epithelial Cell, Normal Epithelial Cell, Sperm, Calcium Crystal, Oxalate Crystal Bacteria, Yeast, Amorphous Urates, Mucus etc. |
Test Principle | Flow cell digital imaging technology, medical image fusion technology, artificial intelligence identification technique |
Channel | Four channels fixed flow counting cell |
Sample Volume | Minimum volume: 3mL, Aspiration volume: 1mL |
Test Speed | 120 samples/hour |
Aspiration Volume | 1ml |
Test Sensitivity | 5 cells/μL |
Accuracy | >95% |
Repeatability | CV<10% |
Cross Contamination Rate | <0.05% |
Data Storage | 200000 |
Report Mode | International general quantitative unit; unit /μL&HPF, complete and illustrated report, with urine chemistry test results and urine sediment test results |
Environment | Temperature: 15°C~35°C |
Optimum temperature: 20°C~25°C | |
Relative humidity: ≤75% | |
Power Supply | AC220V±10%, 50Hz |
Sizes(W×D×H)(mm) | 660x440x570 |
Shipping Size (W×D×H)(mm) | 1170x780x790 |
N.W./G.W. (kg) | 47/100 |
Four channels fixed flow counting cell channel design, channel settlement, cleaning and other detection functions fully guarantee the speed and efficiency of specimen testing. An fully automatic urine sediment analyzer with a channel detection of other channels of sedimentation cleaning function maximizes the savings in testing time.
The microscope automatically ensures that the sample shooting is clear and complete, reducing maintenance costs.
The operator can modify targets misjudged by the instrument. Memory can be stored and automatically modeled after training is completed.
Automatic positioning, tracking, scanning, identification, classification, counting and analysis of components formed in urine using flow counting cells, medical image information scanning technology and artificial vision visual recognition technology.
Fully automated 10-tube orbital sample grating automatically detects the continuous feeding of samples, and the sample area to be analyzed can hold up to 60 samples at a time.
Samples are automatically scanned and positioned at a true distance, requiring no centrifugation, direct detection of original urine, automatic aspiration, and mixing.
The urine sediment analyzer adops of high-precision plated PTFE suction needle and more thorough cleaning of the instrument pipeline, as far as possible, to eliminate cross-contamination.
Fully Automatic Urine Sediment Analyzer Display
An indispensable component that ensures the proper functioning of the urine sediment analyzer display and the accuracy of the samples analysed.
Routine urinalysis
Diagnosis of urinary tract infections
Renal Function Assessment
Screening for urinary stones
Urine monitoring during pregnancy
The fully automatic urine sediment analyzer has a wide range of applications in clinical practice, improving the accuracy, efficiency and standardisation of urinalysis and providing doctors with more reliable diagnostic and therapeutic support.
Urine analyzer can be analysed in its natural state without the need for centrifugation, which can destroy fragile components. Results are quantified in cells/μL, minimising subjectivity. The operating time is minimised and the focus is on qualitative results.
No. Urine sediment analyzer in its natural state can be evaluated without centrifugation. The sample still needs to be gently stirred before analysis, but there is no need to centrifuge the urine, thus saving time and optimising sample quality.
Using an optical lens and image analysis technology, it automatically identifies, counts and analyses a wide range of cells, crystals and other particles in the urine sediment. It uses advanced algorithms and databases to identify and classify different types of cells and crystals and generate quantitative results. This automated system greatly improves efficiency and reduces human error, making urinary sediment analysis more accurate and reliable.
Minimal automated maintenance features save time and eliminate staff frustration.