Availability: | |
---|---|
Quantity: | |
Model | FA-406 |
---|---|
Temperature Range | RT+5~280℃ |
Measuring Range | 0~100% |
Temperature Accuracy | ±1℃ |
Sample Weight | 0.5~15g(generally 2~5g, depending on sample) |
Capacity Per Batch | 6pcs/batch |
Solvent Cup Volume | 80mL |
Solvent Recovery | ≥80% |
Shortened Extraction Time | 20~80% |
Power Supply | AC220V±10%, 50Hz |
Power | 1KW |
Size(W×D×H)(mm) | 650×320×715 |
Shipping Size(W×D×H)(mm) | 830×500×980 |
N.W./G.W. (kg) | 35/70 |
FA-406 fat analyzer integrates the functions of immersion, extraction, leaching, heating, condensation and solvent recovery.
The whole unit is heated by a sealed metal bath, with a wide range of automatic temperature control and uniform heating to ensure safe operation.
Simultaneous testing of up to 6 samples and selection of the optimum temperature according to the difference between the boiling point of the reagents and the ambient temperature.
Reagents can also be recycled to reduce testing costs.
The circuitry is isolated from the extraction space to ensure equipment safety.
Lifting and lowering connection with linear bearing conduction technology for smooth and comfortable lifting and lowering operation.
Unique air insulation technology so that the box is at room temperature, with two major functions of heat preservation and insulation
Rich interface content while displaying the given temperature, actual temperature, given time, and heating time.
Intelligent man-machine dialogue control system, with over-temperature alarm and timed reminder function
It can be quickly separated from a solid or semi-solid mixture of a substance, suitable for determining food, soil, polymers, fiber products, petrochemical products, etc., contained in soluble organic compounds.
Model | FA-406 |
---|---|
Temperature Range | RT+5~280℃ |
Measuring Range | 0~100% |
Temperature Accuracy | ±1℃ |
Sample Weight | 0.5~15g(generally 2~5g, depending on sample) |
Capacity Per Batch | 6pcs/batch |
Solvent Cup Volume | 80mL |
Solvent Recovery | ≥80% |
Shortened Extraction Time | 20~80% |
Power Supply | AC220V±10%, 50Hz |
Power | 1KW |
Size(W×D×H)(mm) | 650×320×715 |
Shipping Size(W×D×H)(mm) | 830×500×980 |
N.W./G.W. (kg) | 35/70 |
FA-406 fat analyzer integrates the functions of immersion, extraction, leaching, heating, condensation and solvent recovery.
The whole unit is heated by a sealed metal bath, with a wide range of automatic temperature control and uniform heating to ensure safe operation.
Simultaneous testing of up to 6 samples and selection of the optimum temperature according to the difference between the boiling point of the reagents and the ambient temperature.
Reagents can also be recycled to reduce testing costs.
The circuitry is isolated from the extraction space to ensure equipment safety.
Lifting and lowering connection with linear bearing conduction technology for smooth and comfortable lifting and lowering operation.
Unique air insulation technology so that the box is at room temperature, with two major functions of heat preservation and insulation
Rich interface content while displaying the given temperature, actual temperature, given time, and heating time.
Intelligent man-machine dialogue control system, with over-temperature alarm and timed reminder function
It can be quickly separated from a solid or semi-solid mixture of a substance, suitable for determining food, soil, polymers, fiber products, petrochemical products, etc., contained in soluble organic compounds.