Availability: | |
---|---|
Quantity: | |
Model | ICB-175C | ICB-275C | ICB-375C | ICB-475C | ICB-800C | ICB-1075C | |
---|---|---|---|---|---|---|---|
Capacity(L) | 175 | 275 | 375 | 475 | 800 | 1075 | |
Circulation Mode | Forced convection | ||||||
Size (WxDxH) | Internal (mm) | 450x420 x930 | 580x510 x935 | 590x550 x1160 | 700x550 x1250 | 960x610 x1370 | 950x700 x1600 |
External (mm) | 610x62 0x1500 | 740x710 x1570 | 750x750 x1730 | 860x750 x1820 | 1130x930 x1980 | 1010x900 x2240 | |
Temperature | Range (℃) | With light: 10~55; Without light: 0~55 | |||||
Fluctuation (℃) | ≦ ±1 | ||||||
Resolution (℃) | 0.1 | ||||||
Uniformity (℃) | ≦ ±1 | ||||||
Sensor | PT100 | ||||||
Humidity | Range | 30~95%RH | |||||
Stability | ±3%RH | ||||||
Method | Internal | ||||||
Sensor | High precision anti-condensation | ||||||
Illumination(Lx) | 0~10000 | 0~15000 | 0~20000 | 0~23000 | 0~25000 | 0~25000 | |
Controller | Microcomputer | ||||||
Display | Large high efinition LCD | ||||||
Timer | 1~99.9h x 30 Segments | ||||||
Material | Internal | Mirror Stainless Steel | |||||
External | Coated cold rolled steel | ||||||
Shelves(Standard / Max ) | 3 / 16 | 3 / 16 | 3 / 21 | 3 / 22 | 3 / 22 | 3 / 22 | |
Test Hole (Optional) | Φ25mm (50mm) | ||||||
Refrigerant | R134a (CFC free) | ||||||
Defrosting Mode | Automatic | ||||||
Safety Device | Visible & Audible over temperaure, over humidity, water shortage alarm; leakage protector, spare temperature control | ||||||
Electricity | Voltage /Frequency | AC 220/110V, 50/60Hz | |||||
Consumption (W) | 860 | 1700 | 2100 | 4000 | 5000 | 6000 | |
N.W./G.W. (kg) | 180/234 | 211/267 | 249/339 | 306/369 | 368/518 | 450/620 | |
Shipping Size (WxDxH) (mm) | 750x1860 x840 | 1010x900 x1880 | 880x980 x2100 | 1010x1000 x2250 | 1290x1070 x2320 | 1290x1170 x2600 | |
Optional | Build-in printer, RS485 port, Φ25mm (50mm) test hole, spare shelf |
When the climate chamber fails, LCD display will show up fault information.
Simulates day and night temperature changes in nature.
User-set parameters are automatically stored in case of power loss and restored upon power restoration.
Multi-segment program control for temperature, humidity, light, time, and heating rate.
Simplifies complex testing processes and enables automatic control and operation.
Audible and visual alarm system, High and low temperature alarms.
Backup temperature control to ensure normal operation in case of main control failure (for heating).
Model | ICB-175C | ICB-275C | ICB-375C | ICB-475C | ICB-800C | ICB-1075C | |
---|---|---|---|---|---|---|---|
Capacity(L) | 175 | 275 | 375 | 475 | 800 | 1075 | |
Circulation Mode | Forced convection | ||||||
Size (WxDxH) | Internal (mm) | 450x420 x930 | 580x510 x935 | 590x550 x1160 | 700x550 x1250 | 960x610 x1370 | 950x700 x1600 |
External (mm) | 610x62 0x1500 | 740x710 x1570 | 750x750 x1730 | 860x750 x1820 | 1130x930 x1980 | 1010x900 x2240 | |
Temperature | Range (℃) | With light: 10~55; Without light: 0~55 | |||||
Fluctuation (℃) | ≦ ±1 | ||||||
Resolution (℃) | 0.1 | ||||||
Uniformity (℃) | ≦ ±1 | ||||||
Sensor | PT100 | ||||||
Humidity | Range | 30~95%RH | |||||
Stability | ±3%RH | ||||||
Method | Internal | ||||||
Sensor | High precision anti-condensation | ||||||
Illumination(Lx) | 0~10000 | 0~15000 | 0~20000 | 0~23000 | 0~25000 | 0~25000 | |
Controller | Microcomputer | ||||||
Display | Large high efinition LCD | ||||||
Timer | 1~99.9h x 30 Segments | ||||||
Material | Internal | Mirror Stainless Steel | |||||
External | Coated cold rolled steel | ||||||
Shelves(Standard / Max ) | 3 / 16 | 3 / 16 | 3 / 21 | 3 / 22 | 3 / 22 | 3 / 22 | |
Test Hole (Optional) | Φ25mm (50mm) | ||||||
Refrigerant | R134a (CFC free) | ||||||
Defrosting Mode | Automatic | ||||||
Safety Device | Visible & Audible over temperaure, over humidity, water shortage alarm; leakage protector, spare temperature control | ||||||
Electricity | Voltage /Frequency | AC 220/110V, 50/60Hz | |||||
Consumption (W) | 860 | 1700 | 2100 | 4000 | 5000 | 6000 | |
N.W./G.W. (kg) | 180/234 | 211/267 | 249/339 | 306/369 | 368/518 | 450/620 | |
Shipping Size (WxDxH) (mm) | 750x1860 x840 | 1010x900 x1880 | 880x980 x2100 | 1010x1000 x2250 | 1290x1070 x2320 | 1290x1170 x2600 | |
Optional | Build-in printer, RS485 port, Φ25mm (50mm) test hole, spare shelf |
When the climate chamber fails, LCD display will show up fault information.
Simulates day and night temperature changes in nature.
User-set parameters are automatically stored in case of power loss and restored upon power restoration.
Multi-segment program control for temperature, humidity, light, time, and heating rate.
Simplifies complex testing processes and enables automatic control and operation.
Audible and visual alarm system, High and low temperature alarms.
Backup temperature control to ensure normal operation in case of main control failure (for heating).