High-resolution LCD display screen.
With built-in microprocessor chip, automatic calibration, automatic temperature compensation, data storage, parameter setup, etc.
Automatic calibration, self-diagnosis, automatically recognizing standard buffer solutions,stable reading display.
Cal points: pH: 1-3pts; conductivity: 1pt. DO: 100%Oxyegn or Zero oxygen calibration.
Each kit comes with an ATC pH probe, a plastic ATC Cond electrode, polarographic type DO probe and 3pcs replaceable sensor caps.
IP54 dustproof and spillproof.
Model | DO-PCB100 | |
---|---|---|
pH | Range | (-2.00-20.00)pH |
Resolution | 0.01/0.1 pH | |
Accuracy | ±0.01 pH ±1digit | |
Cond. | Range | 0~200.0mS/cm, auto divided by range of: 0~19.999μS/cm 20.0~199.9μS/cm 200~1999μS/cm 2.00~19.99mS/cm 20.00~199.9mS/cm |
TDS: 0 -100.0g/L Resistivity: 5.00Ω·cm-100.0MΩ·cm, Salinity: 0-100.0 ppt | ||
Resolution | 0.001 | |
Accuracy | ±1.0 % FS±1digit | |
DO | Range | 0-20.00 mg/L (ppm), 0-200.0 % |
Accuracy/ Resolution | ± 0.30 mg/L; 0.01 or 0.1 mg/L | |
ATC Range | (0 - 50)℃ automatically | |
Salinity Compensation | 0~45 ppt manual | |
Barometric Compensation | 0~200 kPa automatically | |
Temperature | Range | 0-100°C |
Resolution/Accuracy | 0.1℃; ±0.2℃ | |
Data Storage | 450groups | |
Data Output | 1. USB to Flash Disk | |
2. Wireless connection to printer (the printer is optional) | ||
Power Supply | DC12V | |
Packing Including | 1. DO-PCB100 Meter | |
2. 201T ATC pH probe | ||
3. pH buffer solution: pH4.00/7.00/10.01, 50mL, one for each | ||
4. CON201T Plastic ATC Cond probe, K=1.0 | ||
5. Standard Cond solution: 50mL: 84μS/1413μS/12.88mS/cm, one for each; | ||
6. DO01-2M Polarographic DO probe, cable length: 2m | ||
7. DOS-01 Membrane refill solution: 30mL,1pc | ||
8. DOSC Sensor caps: 3pcs/group, 1pkg | ||
9. F01 Flexible probe Holder: 1pc | ||
10. A01 Power adaptor:1pc | ||
Shipping Size (WxDxH)(mm) | 430x600x130 | |
N.W. / G.W. (kg) | 2.2 / 3 |
High-resolution LCD display screen.
With built-in microprocessor chip, automatic calibration, automatic temperature compensation, data storage, parameter setup, etc.
Automatic calibration, self-diagnosis, automatically recognizing standard buffer solutions,stable reading display.
Cal points: pH: 1-3pts; conductivity: 1pt. DO: 100%Oxyegn or Zero oxygen calibration.
Each kit comes with an ATC pH probe, a plastic ATC Cond electrode, polarographic type DO probe and 3pcs replaceable sensor caps.
IP54 dustproof and spillproof.
Model | DO-PCB100 | |
---|---|---|
pH | Range | (-2.00-20.00)pH |
Resolution | 0.01/0.1 pH | |
Accuracy | ±0.01 pH ±1digit | |
Cond. | Range | 0~200.0mS/cm, auto divided by range of: 0~19.999μS/cm 20.0~199.9μS/cm 200~1999μS/cm 2.00~19.99mS/cm 20.00~199.9mS/cm |
TDS: 0 -100.0g/L Resistivity: 5.00Ω·cm-100.0MΩ·cm, Salinity: 0-100.0 ppt | ||
Resolution | 0.001 | |
Accuracy | ±1.0 % FS±1digit | |
DO | Range | 0-20.00 mg/L (ppm), 0-200.0 % |
Accuracy/ Resolution | ± 0.30 mg/L; 0.01 or 0.1 mg/L | |
ATC Range | (0 - 50)℃ automatically | |
Salinity Compensation | 0~45 ppt manual | |
Barometric Compensation | 0~200 kPa automatically | |
Temperature | Range | 0-100°C |
Resolution/Accuracy | 0.1℃; ±0.2℃ | |
Data Storage | 450groups | |
Data Output | 1. USB to Flash Disk | |
2. Wireless connection to printer (the printer is optional) | ||
Power Supply | DC12V | |
Packing Including | 1. DO-PCB100 Meter | |
2. 201T ATC pH probe | ||
3. pH buffer solution: pH4.00/7.00/10.01, 50mL, one for each | ||
4. CON201T Plastic ATC Cond probe, K=1.0 | ||
5. Standard Cond solution: 50mL: 84μS/1413μS/12.88mS/cm, one for each; | ||
6. DO01-2M Polarographic DO probe, cable length: 2m | ||
7. DOS-01 Membrane refill solution: 30mL,1pc | ||
8. DOSC Sensor caps: 3pcs/group, 1pkg | ||
9. F01 Flexible probe Holder: 1pc | ||
10. A01 Power adaptor:1pc | ||
Shipping Size (WxDxH)(mm) | 430x600x130 | |
N.W. / G.W. (kg) | 2.2 / 3 |